Loading capacity of CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants with different cements

被引:8
|
作者
Nueesch, Reto [1 ]
Conejo, Julian [2 ]
Mante, Francis [2 ]
Fischer, Jens [3 ,4 ]
Martin, Sabrina [4 ]
Rohr, Nadja [3 ]
Blatz, Markus B. [2 ]
机构
[1] Univ Zurich, Ctr Dent Med, Zurich, Switzerland
[2] Univ Penn, Sch Dent Med, Dept Prevent & Restorat Sci, Philadelphia, PA 19104 USA
[3] Univ Ctr Dent Med, Div Dent Mat & Engn, Dept Reconstruct Dent, Basel, Switzerland
[4] VITA Zahnfabrik, Bad Sackingen, Germany
关键词
CAD/CAM crown; ceramic implant; compressive strength; feldspathic crown; fracture load; resin composite cement; zirconia implant; SINGLE-TOOTH REPLACEMENT; FRACTURE-RESISTANCE; TITANIUM IMPLANTS; DENTAL IMPLANTS; BITE FORCE; RESIN; SURVIVAL; RESTORATIONS; CONVERSION; REMOVAL;
D O I
10.1111/clr.13404
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective This study evaluated the loading capacity of CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants with different cements. Material and methods Fifty one-piece zirconia implants were embedded in epoxy resin. The abutment aspect of one implant was optically scanned and a standardized upper canine was designed with CAD-software. Fifty feldspathic ceramic crowns were milled, polished, and mounted on the implants either without any cement, with a temporary cement or with three different composite resin cements after surface pretreatment as recommended by the manufacturers (n = 10). After storage in distilled water at 37 degrees C for 24 hr, specimens were loaded until fracture on the palatal surface of the crown at an angle of 45 degrees to the long axis of the implant and loads until fracture were detected and compared. Compressive strength of the investigated cement materials was determined. Statistical analyses were done with One-way ANOVA followed by post hoc Fisher LSD test (alpha = 0.05). Results The cements revealed significantly different compressive strength values (temporary cement: 37.1 +/- 7.0 MPa; composite resin cements: 185.8 +/- 21.3, 277.9 +/- 22.1, and 389.0 +/- 13.6 MPa, respectively). Load-at-fracture values had an overall mean value of 237.1 +/- 58.2 N with no significant difference among the composite resin cements (p > 0.05). Fracture load values with the temporary cement or without cement were significantly lower (p < 0.002). Conclusions CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants provide sufficient resistance to intraoral forces.
引用
收藏
页码:178 / 186
页数:9
相关论文
共 13 条
  • [1] Application of one-piece endodontic crowns fabricated with CAD-CAM system to molars
    Hiraba, Haruto
    Nishio, Kensuke
    Takeuchi, Yoshimasa
    Ito, Takashi
    Yamamori, Tetsuo
    Kamimoto, Atsushi
    JAPANESE DENTAL SCIENCE REVIEW, 2024, 60 : 81 - 94
  • [2] Effects of different surface treatments on the cyclic fatigue strength of one-piece CAD/CAM zirconia implants
    Ding, Qian
    Zhang, Lei
    Bao, Rui
    Zheng, Gang
    Sun, Yuchun
    Xie, Qiufei
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 84 : 249 - 257
  • [3] Clinical performance of two different CAD/CAM-fabricated ceramic crowns: 2-Year results
    Seydler, Bodo
    Schmitter, Marc
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (02): : 212 - 216
  • [4] Scanning Electron Microscope Analysis of Adhesively Bonded Two-piece Abutments versus One-piece CAD/CAM Zirconia Abutments
    Ketabi, Ali-Reza
    Ketabi, Sandra
    Helmstaedter, Bernd
    Lauer, Hans-Christoph
    Brenner, Martin
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2018, 6 (05): : 365 - 371
  • [5] Biomechanical properties of polymer-infiltrated ceramic crowns on one-piece zirconia implants after long-term chewing simulation
    Baumgart, Pia
    Kirsten, Holger
    Haak, Rainer
    Olms, Constanze
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [6] Biomechanical properties of polymer-infiltrated ceramic crowns on one-piece zirconia implants after long-term chewing simulation
    Pia Baumgart
    Holger Kirsten
    Rainer Haak
    Constanze Olms
    International Journal of Implant Dentistry, 4
  • [7] Digital Wear Analysis of Different CAD/CAM-Fabricated Monolithic Ceramic Implant-Supported Single Crowns Using Two Optical Scanners
    Marchand, Laurent
    Sailer, Irena
    Lee, Hyeonjong
    Mojon, Philippe
    Pitta, Joao
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (03) : 357 - 364
  • [8] Marginal and internal fit of feldspathic ceramic CAD/CAM crowns fabricated via different extraoral digitization methods: a micro-computed tomography analysis
    Oguz, Ece Irem
    Kilicarslan, Mehmet Ali
    Ocak, Mert
    Bilecenoglu, Burak
    Ekici, Zeynep
    ODONTOLOGY, 2021, 109 (02) : 440 - 447
  • [9] Marginal and internal fit of feldspathic ceramic CAD/CAM crowns fabricated via different extraoral digitization methods: a micro-computed tomography analysis
    Ece İrem Oğuz
    Mehmet Ali Kılıçarslan
    Mert Ocak
    Burak Bilecenoğlu
    Zeynep Ekici
    Odontology, 2021, 109 : 440 - 447
  • [10] Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study
    Bjelopavlovic, Monika
    Weyhrauch, Michael
    Scheller, Herbert
    Wentaschek, Stefan
    Lehmann, Karl Martin
    MATERIALS, 2022, 15 (19)