Precision of Targeting Device for Subtalar Screw Placement

被引:4
|
作者
Betz, Michael [1 ]
Wieser, Karl [1 ]
Vich, Magdalena [1 ]
Wirth, Stephan Hermann [1 ]
Espinosa, Norman [1 ]
机构
[1] Univ Zurich, Dept Orthopaed, CH-8008 Zurich, Switzerland
关键词
Subtalar; Arthritis; Target; Device; Precision; Radiation; COMPUTER-ASSISTED SURGERY; ARTHRODESIS; RADIATION; ANKLE; FOOT;
D O I
10.3113/FAI.2012.0519
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: When performing subtalar arthrodesis, proper screw placement is fundamental to provide primary stability and to help ensure bone healing. In inexperienced hands this step can be time-consuming and exposes surgeons and patients to radiation. By means of a targeting device these potential drawbacks and dangers could be reduced. It was hypothesized that a specifically designed targeting device would reduce radiation exposure while improving screw placement when compared with the conventional "free-hand" method. Methods: Twenty matched-pairs of cadaveric hindfoot specimens (Thiel fixation) were prepared for the purpose of the study. The specimens were randomly assigned into two groups consisting of 10 specimens each: in Group 1 screw placement was performed with the targeting device and in Group 2 screw placement was performed under fluoroscopic control. Screw placement was radiographically judged to be optimal, suboptimal and poor. An experienced, fellowship-trained foot and ankle surgeon and a resident, who had never done subtalar fusions performed the screw placements. Exposure to radiation was assessed by means of the dose area product given by the fluoroscope. Results: Optimal screw positioning was achieved in both groups in ten out of 20 specimens (Group 1, n = 5; Group 2, n = 5). Suboptimal screw placement was found in eight cases (Group I, n = 4; Group 2, n = 4). There were two failures which occurred in fusions performed by the resident (Group 1, n = I; Group 2, n = 1). Exposure to radiation was significantly reduced in Group 1 when compared with Group 2 (4.1cGy*cm(2) versus 8.1cGy*cm(2); p = 0.012). No lesion of neurovascular structures due to aiming device placement occurred in Group 1. Conclusion: A target-device for screw-placement did not provide a significant technical advantage but did result in less radiation exposure.
引用
收藏
页码:519 / 523
页数:5
相关论文
共 50 条
  • [1] A target device to improve subtalar screw placement - A cadaver study investigating effect on precision and radiation exposure
    Espinosa, Norman
    Betz, Michael
    Wieser, Karl
    Vich, Magdalena
    Wirth, Stephan
    [J]. SWISS MEDICAL WEEKLY, 2012, 142 : S29 - S29
  • [2] Screw Placement in Subtalar Arthrodesis: A Biomechanical Study
    Chuckpaiwong, Bavornrit
    Easley, Mark E.
    Glisson, Richard R.
    [J]. FOOT & ANKLE INTERNATIONAL, 2009, 30 (02) : 133 - 141
  • [3] Biomechanical Evaluation of Subtalar Fusion: The Influence of Screw Configuration and Placement
    Hungerer, Sven
    Eberle, Sebastian
    Lochner, Susanne
    Maier, Michael
    Hoegel, Florian
    Penzkofer, Rainer
    Augat, Peter
    [J]. JOURNAL OF FOOT & ANKLE SURGERY, 2013, 52 (02): : 177 - 183
  • [4] The subtalar distraction screw
    Blake, SM
    Loxdale, PH
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2005, 87 (03) : 206 - 206
  • [5] DEVICE FOR PRECISION PEANUT SEED PLACEMENT
    WRIGHT, FS
    MOZINGO, RW
    [J]. AGRONOMY JOURNAL, 1995, 87 (02) : 279 - 280
  • [6] Transpedicular Screw Insertion Guidance Device (TSIGD), A New Device for Spinal Transpedicular Screw Placement (A Pilot Study)
    Torkashvand, Mostafa
    Moradi, Mehran
    Abrishamkar, Saeid
    Rezvani, Majid
    Sabouri, Masih
    Miri, Mojtaba
    Fard, Salman Abbasi
    [J]. ARCHIVES OF NEUROSCIENCE, 2014, 1 (01)
  • [7] A novel guide device improves the accuracy of pedicle screw placement
    Yang, Lei
    Li, Haijun
    Tang, Jian
    Ge, Dawei
    Cao, Xiaojian
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (06): : 8634 - 8640
  • [8] CUSTOM SCREW-HOLDING DEVICE FOR PLACEMENT OF IMPLANT PROSTHESES
    ROMEROWSKI, J
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (06): : 636 - 636
  • [9] The effect of an aiming device on the accuracy of humeral transcondylar screw placement
    Neal, Katherine M. M.
    Gallaher, Hayley M. M.
    Thompson, Alexis
    Kerby, Mary D. D.
    [J]. VETERINARY SURGERY, 2023, 52 (04) : 538 - 544
  • [10] Design and application of subaxial cervical pedicle screw placement guide device
    Wang, Qiang
    Xing, Runlin
    Zeng, Yiwen
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2019, 17 (06) : 4357 - 4362