Detection of motion artifacts in photoplethysmographic signals based on time and period domain analysis

被引:0
|
作者
Couceiro, R. [1 ]
Carvalho, P. [1 ]
Paiva, R. P. [1 ]
Henriques, J. [1 ]
Muehlsteff, J.
机构
[1] Univ Coimbra, Fac Sci & Technol, Dept Informat Engn, Coimbra, Portugal
关键词
PULSE OXIMETRY; REDUCTION; WAVE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The presence of motion artifacts in the photoplethysmographic (PPG) signals is one of the major obstacles in the extraction of reliable cardiovascular parameters in real time and continuous monitoring applications. In the current paper we present an algorithm for motion artifact detection, which is based on the analysis of the variations in the time and period domain characteristics of the PPG signal. The extracted features are ranked using a feature selection algorithm (NMIFS) and the best features are used in a Support Vector Machine classification model to distinguish between clean and corrupted sections of the PPG signal. The results achieved by the current algorithm (SE: 0.827 and SP: 0.927) show that both time and especially period domain features play an important role in the discrimination of motion artifacts from clean PPG pulses.
引用
收藏
页码:2603 / 2606
页数:4
相关论文
共 50 条
  • [1] Detection of motion artifact patterns in photoplethysmographic signals based on time and period domain analysis
    Couceiro, R.
    Carvalho, P.
    Paiva, R. P.
    Henriques, J.
    Muehlsteff, J.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2014, 35 (12) : 2369 - 2388
  • [2] HHT based signal decomposition for reduction of motion artifacts in Photoplethysmographic signals
    Raghuram, M.
    Madhav, K. Venu
    Krishna, E. Hari
    Komalla, Nagarjuna Reddy
    Sivani, Kosaraju
    Reddy, K. Ashoka
    [J]. 2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 1730 - 1734
  • [3] An Automatic Method for Motion Artifacts Detection in Photoplethysmographic Signals Referenced With Electrocardiography Data
    Vaz, Pedro
    Henriques, Jorge
    de Carvalho, Paulo
    Couceiro, Ricardo
    [J]. 2014 7TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2014), 2014, : 704 - 708
  • [4] On the performance of wavelets in reducing motion artifacts from photoplethysmographic signals
    Raghuram, M.
    Madhav, K. Venu
    Krishna, E. Hari
    Reddy, K. Ashoka
    [J]. 2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [5] Influence of Motion Artifacts on Photoplethysmographic Signals for Measuring Pulse Rates
    Lee, Yunjoo
    Han, Hyonyoung
    Kim, Jung
    [J]. 2008 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS, VOLS 1-4, 2008, : 854 - 857
  • [6] Machine Learning Applied to Reference Signal-Less Detection of Motion Artifacts in Photoplethysmographic Signals: A Review
    Argüello-Prada, Erick Javier
    Castillo García, Javier Ferney
    [J]. Sensors, 2024, 24 (22)
  • [7] E2MD for Reduction of Motion Artifacts from Photoplethysmographic Signals
    Raghuram, M.
    Sivani, Kosaraju
    Reddy, K. Ashoka
    [J]. 2014 INTERNATIONAL CONFERENCE ON ELECTRONICS AND COMMUNICATION SYSTEMS (ICECS), 2014,
  • [8] Determination of Absolute Heart Beat from Photoplethysmographic Signals in the Presence of Motion Artifacts
    Karna, Viswavardhan Reddy
    Kumar, Navin
    [J]. 2018 SECOND INTERNATIONAL CONFERENCE ON ADVANCES IN ELECTRONICS, COMPUTERS AND COMMUNICATIONS (ICAECC), 2018,
  • [9] A comb filter based signal processing method to effectively reduce motion artifacts from photoplethysmographic signals
    Peng, Fulai
    Liu, Hongyun
    Wang, Weidong
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (10) : 2159 - 2170
  • [10] Noninvasive estimation of blood pressure using photoplethysmographic signals in the period domain
    Yan, Y. S.
    Zhang, Y. T.
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3583 - 3584