Evaluation of the registration of temporal series of contrast-enhanced perfusion magnetic resonance 3D images of the liver

被引:6
|
作者
Dura, E. [1 ]
Domingo, J. [1 ]
Ayala, G. [2 ]
Marti-Bonmati, L. [3 ]
机构
[1] Univ Valencia, Dept Informat, E-46100 Valencia, Spain
[2] Univ Valencia, Dept Stat & Operat Res, E-46100 Valencia, Spain
[3] Univ Valencia, Hosp Univ & Politecn La Fe, E-46100 Valencia, Spain
关键词
Volume sequence registration; Image registration evaluation; MRI contrast diffusion; Functional data; PERFORMANCE EVALUATION; CT; SEGMENTATION; TIME; OPTIMIZATION; DEFORMATIONS; ALGORITHM;
D O I
10.1016/j.cmpb.2012.04.015
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The registration of 2D and 3D images is one of the key tasks in medical image processing and analysis. Accurate registration is a crucial preprocessing step for many tasks; consequently, the evaluation of its accuracy becomes necessary. Unfortunately, this is a difficult task, especially when no golden pattern (true result) is available and when the signal values may have changed between successive images to be registered. This is the case this paper deals with: we have a series of 3D images, magnetic resonance images (MRI) of the liver and adjacent areas that have to be registered. They have been taken while a contrast is diffused through the liver tissue, so intensity of each observed point changes for two reasons: contrast diffusion/perfusion and deformation of the liver (due to body movement and breathing). In this paper, we introduce a new method to automatically compare two or more registration algorithms applied to the same case of a perfusion magnetic resonance dynamic image so that the best of them can be chosen when no ground truth is available. This is done by modeling the function that gives the intensity at a given point as a functional datum, and using statistical techniques to assess its change in comparison with other functions. An example of the application is shown by comparing two parametrizations of a B-spline based registration algorithm. The main result of the proposed method is a suggestive evidence to guide the physician in the process of selecting a registration algorithm, that recommends the algorithm of minimal complexity but still suitable for the case to be analyzed. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:932 / 945
页数:14
相关论文
共 50 条
  • [1] IMAGE REGISTRATION FOR ABDOMINAL DYNAMIC CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGES
    Lausch, Anthony
    Ebrahimi, Mehran
    Martel, Anne
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 561 - 565
  • [2] Registration of freehand 3D ultrasound and magnetic resonance liver images
    Penney, GP
    Blackall, JM
    Hamady, MS
    Sabharwal, T
    Adam, A
    Hawkes, DJ
    MEDICAL IMAGE ANALYSIS, 2004, 8 (01) : 81 - 91
  • [3] Registration of time-series contrast enhanced magnetic resonance images for renography
    Yim, PJ
    Marcos, HB
    McAuliffe, M
    McGarry, D
    Heaton, I
    Choyke, PL
    FOURTEENTH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2001, : 516 - 520
  • [4] Evaluation of Free Flap Perfusion with Dynamic Contrast-Enhanced Magnetic Resonance Imaging
    Prantl, Lukas
    Fellner, Claudia
    Jung, Michael E.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 126 (02) : 100E - 101E
  • [5] Automated quantification of myocardial perfusion based on segmentation and non-rigid registration of contrast-enhanced cardiac magnetic resonance images
    Giacomo Tarroni
    Cristiana Corsi
    Federico Veronesi
    James Walter
    Claudio Lamberti
    Roberto M Lang
    Victor Mor-Avi
    Amit R Patel
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [6] Use of fat saturation with contrast-enhanced 3D SPGR magnetic resonance angiography
    Hilfiker, PR
    Heiss, SG
    Alley, MT
    Herfkens, RJ
    RADIOLOGY, 1999, 213P : 437 - 437
  • [7] An Unbiased Groupwise Registration Algorithm for Correcting Motion in Dynamic Contrast-Enhanced Magnetic Resonance Images
    Mojica, Mia
    Ebrahimi, Mehran
    IMAGE ANALYSIS FOR MOVING ORGAN, BREAST, AND THORACIC IMAGES, 2018, 11040 : 42 - 52
  • [8] Assessment of Bone Perfusion with Contrast-Enhanced Magnetic Resonance Imaging
    Lee, Jonathan H.
    Dyke, Jonathan P.
    Ballon, Douglas
    Ciornbor, Deborah McK.
    Tung, Glenn
    Aaron, Roy K.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2009, 40 (02) : 249 - +
  • [9] Dynamic contrast-enhanced magnetic resonance imaging: fundamentals and application to the evaluation of the peripheral perfusion
    Gordon, Yaron
    Partovi, Sasan
    Mueller-Eschner, Matthias
    Amarteifio, Erick
    Baeuerle, Tobias
    Weber, Marc-Andre
    Kauczor, Hans-Ulrich
    Rengier, Fabian
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (02) : 147 - 164
  • [10] Improved detection of liver metastasis by registration and subtraction of dynamic contrast-enhanced magnetic resonance imaging
    Passera, Katia M.
    Mainardi, Luca T.
    Setti, Ernesto
    Potepan, Paolo
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 59 - +