The use of auto-titrating continuous positive airway pressure for treatment of adult obstructive sleep apnea

被引:0
|
作者
Berry, RB
Parish, JM
Hartse, KM
机构
[1] Univ Florida, Hlth Sci Ctr, Malcolm Randall VAMC, Gainesville, FL 32610 USA
[2] Mayo Clin, Scottsdale, AZ USA
[3] Sleep Consultants, Ft Worth, TX USA
关键词
obstructive sleep apnea; CPAP; auto-titrating CPAP; autoPAP; APAP;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This paper reviews the efficacy of auto-titrating continuous positive airway pressure (APAP) for treatment of obstructive sleep apnea. It is based on a review of 30 articles published in peer review journals conducted by a task force appointed by the American Academy of Sleep Medicine to develop practice parameters for use of APAP devices for treatment of obstructive sleep apnea (OSA). The data indicate that APAP can be used to treat many patients with OSA (auto-adjusting) or to identify an effective optimal fixed level of continuous positive airway pressure (CPAP) for treatment (auto-titration). Patients with significant congestive heart failure, chronic obstructive pulmonary disease (COPD), or significant amounts of central apnea were excluded from many treatment trials and there is insufficient evidence that APAP can be used to treat these patients. Many clinical trials have been performed in patients already on CPAP or with the initial APAP night in a laboratory setting. At this time only a few studies have evaluated initial titration with APAP in CPAP-naive patients in an unattended setting. Further studies of APAP in this circumstance are needed. No studies have systematically compared the efficacy of one APAP technology with another. Devices using different technology may not give the same results in a given patient. Devices solely dependent on vibration may not work in non-snorers or patient who have undergone upper-airway surgery. High mask or mouth leaks may prevent adequate titration in devices monitoring snoring, flow, or impedance (forced oscillation technique). Review of the raw data to identify periods of high leak was performed in several of the APAP titration studies, to identify a pressure for fixed CPAP treatment or to determine if the titration was adequate. There is conflicting evidence for and against the premise that treatment with APAP increases acceptance and adherence compared to fixed CPAP. In studies demonstrating an increase in adherence with APAP, there was similar improvement in measures of daytime sleepiness as with fixed CPAP treatment, Further studies are needed to determine if APAP can increase acceptance or adherence with positive pressure treatment in patients with OSA.
引用
收藏
页码:148 / 173
页数:26
相关论文
共 50 条
  • [1] THE USE OF AUTO-TITRATING CONTINUOUS POSITIVE AIRWAY PRESSURE (AUTO CPAP) FOR OBSTRUCTIVE SLEEP APNEA IN CHILDREN WITH NEUROLOGICAL DISORDER
    Platter, L.
    Urbano, G.
    Roberto, L.
    Sudhakar, R.
    Tablizo, M.
    SLEEP, 2020, 43 : A343 - A343
  • [2] The Use of Auto-Titrating Continuous Positive Airway Pressure (AutoCPAP) for Obstructive Sleep Apnea Syndrome in Children with Obesity
    Benke, Sarah
    Okorie, Caroline U. A.
    Tablizo, MaryAnne A.
    CHILDREN-BASEL, 2021, 8 (12):
  • [3] Auto-titrating continuous positive airway pressure for treating adult patients with sleep apnea syndrome
    d'Ortho, MP
    CURRENT OPINION IN PULMONARY MEDICINE, 2004, 10 (06) : 495 - 499
  • [4] The Use of Auto-titrating Continuous Positive Airway Pressure (autoCPAP) for Obstructive Sleep Apnea Syndrome in Children with Obesity
    Benke, S.
    Okorie, C. U. A.
    Platter, L.
    Tablizo, M. A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [5] Empiric treatment of clinically diagnosed obstructive sleep apnea using auto-titrating continuous positive airway pressure
    Drummond, FE
    Doelken, P
    Frye, MD
    CHEST, 2005, 128 (04) : 223S - 223S
  • [6] Practice parameters for the use of auto-titrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome
    Littner, M
    Hirshkowitz, M
    Davila, D
    Anderson, WM
    Kushida, CA
    Woodson, T
    Johnson, SF
    Wise, MS
    SLEEP, 2002, 25 (02) : 143 - 147
  • [7] Auto-titrating versus standard continuous positive airway pressure for the treatment of obstructive sleep apnea: Results of a meta-analysis
    Ayas, NT
    Patel, SR
    Malhotra, A
    Schulzer, M
    Malhotra, M
    Jung, D
    Fleetham, J
    White, DP
    SLEEP, 2004, 27 (02) : 249 - 253
  • [8] Optimal pressure in obstructive sleep apnea: auto-titrating positive airway pressure versus predictive equations
    Galal, Iman
    Diab, Haytham S.
    EGYPTIAN JOURNAL OF CHEST DISEASES AND TUBERCULOSIS, 2021, 70 (01): : 99 - 106
  • [9] Auto-titrating versus fixed continuous positive airway pressure for the treatment of obstructive sleep apnea: a systematic review with meta-analyses
    Ip, Stanley
    D'Ambrosio, Carolyn
    Patel, Kamal
    Obadan, Ndidiamaka
    Kitsios, Georgios D.
    Chung, Mei
    Balk, Ethan M.
    SYSTEMATIC REVIEWS, 2012, 1
  • [10] Auto-titrating versus fixed continuous positive airway pressure for the treatment of obstructive sleep apnea: a systematic review with meta-analyses
    Stanley Ip
    Carolyn D'Ambrosio
    Kamal Patel
    Ndidiamaka Obadan
    Georgios D Kitsios
    Mei Chung
    Ethan M Balk
    Systematic Reviews, 1 (1)