Sterilization efficacy of a coaxial microwave plasma flow at atmospheric pressure

被引:31
|
作者
Sato, T [1 ]
Fujioka, K
Ramasamy, R
Urayama, T
Fujii, S
机构
[1] Tohoku Univ, Inst Fluid Sci, Sendai, Miyagi 9808577, Japan
[2] Adtec Plasma Technol Co Ltd, Fukuyama, Hiroshima 7210942, Japan
关键词
argon; atmospheric pressure; coaxial microwave; plasma; Geobacillus stearothermophilus; sterilization;
D O I
10.1109/TIA.2006.870039
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A coaxial cable for microwave transmission type of atmospheric low-temperature plasma source was developed. The plasma source has the advantages of portability, simple configuration, and ability to operate with a wide range of gases and mixtures of such gases. It mainly consists of a cavity, a quartz discharge tube, a coaxial cable, a microwave power source, and a gas supply system. Using this plasma source, the authors tried to clarify its sterilization efficacy against Geobacillus stearothertnophilus. A log reduction number of G. stearothermophilus of at least 5 (10(-5)) was obtained under the following operating conditions: gas flow rate of argon of 14 SL/min, input power is 400 W, and substrate surface temperature of 353 K. Distributions of temperature and velocities of gas were also measured two-dimensionally by using an E-type thermocouple and a Pitot tube, respectively. The temperature distributions and the peak value of temperature were found to be influenced by the gas flow rate and the kinds of gas mixtures.
引用
收藏
页码:399 / 404
页数:6
相关论文
共 50 条
  • [1] Sterilization characteristics by a coaxial microwave plasma flow at atmospheric pressure
    Sato, T
    Fujioka, K
    Ramasamy, R
    Urayama, T
    Fujii, S
    CONFERENCE RECORD OF THE 2004 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4: COVERING THEORY TO PRACTICE, 2004, : 937 - 940
  • [2] Sterilization efficacy of steam plasma flow at atmospheric pressure
    Furui, Takeshi
    Sato, Takehiko
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2008, 74 (04): : 879 - 883
  • [3] Sterilization of Escherichia coli by a coaxial microwave plasma flow
    Sato, T
    Nakatani, T
    Doi, A
    Urayama, T
    Miyahara, T
    Conference Record of the 2005 IEEE Industry Applications Conference, Vols 1-4, 2005, : 767 - 770
  • [4] Characteristics of Nonequilibrium Plasma Flow and Its Sterilization Efficacy in a Tube at Atmospheric Pressure
    Sato, Takehiko
    Furuya, Osamu
    Nakatani, Tatsuyuki
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (01) : 44 - 49
  • [5] Stable microwave coaxial cavity plasma system at atmospheric pressure
    Song, H.
    Hong, J. M.
    Lee, K. H.
    Choi, J. J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (05):
  • [6] Sterilization mechanism for Escherichia coli by plasma flow at atmospheric pressure
    Sato, Takehiko
    Miyahara, Takashi
    Doi, Akiko
    Ochiai, Shiroh
    Urayama, Takuya
    Nakatani, Tatsuyuki
    APPLIED PHYSICS LETTERS, 2006, 89 (07)
  • [7] Rotating discharges in a coaxial microwave plasma source under atmospheric pressure
    Liu, Zhuang
    Zhang, Wencong
    Yu, Jie
    Wu, Li
    Huang, Kama
    JOURNAL OF APPLIED PHYSICS, 2019, 126 (11)
  • [8] Flow fluctuation induced by coaxial plasma device at atmospheric pressure
    Tang, Yong
    Yao, Qiang
    Cui, Wei
    Pu, Yikang
    Li, Shuiqing
    APPLIED PHYSICS LETTERS, 2018, 113 (22)
  • [9] Fungal sterilization using microwave-induced argon plasma at atmospheric pressure
    Park, JC
    Park, BJ
    Han, DW
    Lee, DH
    Lee, IS
    Hyun, SO
    Chun, MS
    Chung, KH
    Aihara, M
    Takatori, K
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2004, 14 (01) : 188 - 192
  • [10] Sterilization using a microwave-induced argon plasma system at atmospheric pressure
    Park, BJ
    Lee, DH
    Park, JC
    Lee, IS
    Lee, KY
    Hyun, SO
    Chun, MS
    Chung, KH
    PHYSICS OF PLASMAS, 2003, 10 (11) : 4539 - 4544