Combined 3T Diffusion Tensor Tractography and 1H-MR Spectroscopy in Motor Neuron Disease

被引:27
|
作者
Nelles, M. [1 ]
Block, W. [1 ]
Traeber, F. [1 ]
Wuellner, U. [2 ]
Schild, H. H. [1 ]
Urbach, H. [1 ]
机构
[1] Univ Bonn, Med Ctr, Dept Radiol, D-53105 Bonn, Germany
[2] Univ Bonn, Med Ctr, Dept Neurol, D-53105 Bonn, Germany
关键词
D O I
10.3174/ajnr.A1201
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Diagnostic confidence in motor neuron disease maybe improved by the use of advanced MR imaging techniques. Our aim was to assess the accuracy (sensitivity/specificity) and agreement of combined H-1-MR spectroscopy (proton MR spectroscopy) and diffusion tensor imaging (DTI) at 3T in patients with suspected motor neuron disease regarding detection of upper motor neuron (UMN) dysfunction. MATERIALS AND METHODS: Eighteen patients with suspected motor neuron disease were studied with MR spectroscopy/DTI and clinically rated according to the El-Escorial and ALSFRS-R scales. For MR spectroscopy, absolute N-acetylaspartate (NAA), choline (Cho), and phosphocreatine (PCr) concentrations and relative NAA/Cho and NAA/PCr ratios of corresponding volumes of interest within the primary motor cortex were calculated. For DTI, fractional anisotropy (FA) and mean diffusivity (MD) were measured bilaterally at the level of the precentral gyrus, corona radiata, internal capsule, cerebral peduncles, pons, and pyramid. FA and MID statistics were averaged on the corticospinal tracts (CSTs) as a whole to account for a region-independent analysis. RESULTS: MR spectroscopy indicated NAA reduction beyond the double SD of controls in 6 of 8 patients with clinical evidence for UMN involvement. Congruently, the mean FA of these patients was significantly lower in the upper 3 regions of measurements (P < .01). Overall, MR spectroscopy and DTI were concordant in all except 3 cases: 1 was correctly excluded from motor neuron disease by DTI (genetically proved Kennedy syndrome), whereas MR spectroscopy indicated CST involvement. MR spectroscopy and DTI each were false-positive for CST affection in 1 patient with lower motor neuron involvement only. CONCLUSION: Combined MR spectroscopy/DTI at 3T effectively adds to the detection of motor neuron disease with a high degree of accordance.
引用
收藏
页码:1708 / 1714
页数:7
相关论文
共 50 条
  • [1] Brain 1H-MR spectroscopy in clinical neuroimaging at 3T
    Tchofo, P. Jissendi
    Baleriaux, D.
    JOURNAL OF NEURORADIOLOGY, 2009, 36 (01) : 24 - 40
  • [2] Metabolic findings on 3T 1H-MR Spectroscopy in peritumoral brain edema
    Ricci, R.
    Bacci, A.
    Tugnoli, V.
    Battaglia, S.
    Maffei, M.
    Agati, R.
    Leonardi, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (07) : 1287 - 1291
  • [3] 1H-MR spectroscopy of suspicious breast mass lesions at 3T: a clinical experience
    Stefania Montemezzi
    Carlo Cavedon
    Lucia Camera
    Gabriele Meliadò
    Francesca Caumo
    Ilaria Baglio
    Francesco Sardanelli
    La radiologia medica, 2017, 122 : 161 - 170
  • [4] 1H-MR spectroscopy of suspicious breast mass lesions at 3T: a clinical experience
    Montemezzi, Stefania
    Cavedon, Carlo
    Camera, Lucia
    Meliado, Gabriele
    Caumo, Francesca
    Baglio, Ilaria
    Sardanelli, Francesco
    RADIOLOGIA MEDICA, 2017, 122 (03): : 161 - 170
  • [5] 3T 1H-MR spectroscopy in grading of cerebral gliomas:: Comparison of short and intermediate echo time sequences
    Kim, J. -H.
    Chang, K. -H.
    Na, D. G.
    Song, I. C.
    Kwon, B. J.
    Han, M. H.
    Kim, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (07) : 1412 - 1418
  • [6] Myocardial lipid content in Fabry disease: a combined 1H-MR spectroscopy and MR imaging study at 3 Tesla
    Petritsch, B.
    Koestler, H.
    Weng, A. M.
    Horn, M.
    Gassenmaier, T.
    Kunz, A. S.
    Weidemann, F.
    Wanner, C.
    Bley, T. A.
    Beer, M.
    BMC CARDIOVASCULAR DISORDERS, 2016, 16
  • [7] Myocardial lipid content in Fabry disease: a combined 1H-MR spectroscopy and MR imaging study at 3 Tesla
    B. Petritsch
    H. Köstler
    A. M. Weng
    M. Horn
    T. Gassenmaier
    A. S. Kunz
    F. Weidemann
    C. Wanner
    T. A. Bley
    M. Beer
    BMC Cardiovascular Disorders, 16
  • [8] Age Dependency of Myocardial Triglyceride Content: A 3T High-Field 1H-MR Spectroscopy Study
    Petritsch, B.
    Gassenmaier, T.
    Kunz, A. S.
    Donhauser, J.
    Goltz, J. P.
    Bley, T. A.
    Horn, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (11): : 1016 - 1021
  • [9] Multi-tensor Tractography of the Motor Pathway at 3T: A Volunteer Study
    Akter, Masuma
    Hirai, Toshinori
    Sasao, Akira
    Nishimura, Shinichiro
    Uetani, Hiroyuki
    Iwashita, Koya
    Yamashita, Yasuyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2011, 10 (01) : 59 - 63
  • [10] Diffusion tensor MR imaging: Fiber tracking at 3T
    Lim, CCT
    Cheng, S
    Zimine, I
    Xu, M
    Sitoh, YY
    Yeo, TT
    Golay, X
    Ng, YK
    Hui, F
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 121 - 121