New design of cold finger for sample preparation in open system: Determination of Hg in biological samples by CV-AAS

被引:58
|
作者
Oreste, Eliezer Quadro [1 ]
de Jesus, Alexandre [2 ]
de Oliveira, Richard Macedo [1 ]
da Silva, Marcia Messias [2 ]
Vieira, Mariana Antunes [1 ]
Ribeiro, Anderson Schwingel [1 ]
机构
[1] Univ Fed Pelotas, Ctr Ciencias Quim Farmaceut & Alimentos, Programa Posgrad Quim, Lab Metrol Quim, BR-96160000 Capao Do Leao, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
关键词
Sample digestion; Open system; Cold finger; Mercury; Biological samples; CV-AAS; ATOMIC-ABSORPTION-SPECTROMETRY; TOTAL MERCURY; ENVIRONMENTAL-SAMPLES; SEDIMENTS; ELEMENTS;
D O I
10.1016/j.microc.2012.05.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents studies involving the determination of Hg in biological samples by cold vapor atomic absorption spectrometry (CV-AAS) using a simple and inexpensive system for sample digestion. The system consists of a glass tube that is closed with a small glass tube filled with cold water, which is called cold finger, and helps the recirculation of the acids within the bigger tube. The use of cold finger avoided the loss of analyte and the excessive evaporation of the acids during the heating. Thus, lower amount of acid was required, decreasing the risk of contamination. Studies of temperature of the digester block were performed with aqueous standard solutions in an interval between 80 and 120 degrees C. No significant loss of analyte was observed when compared with the open system. Certified reference materials (CRMs) were used to evaluate the accuracy of the proposed methodology. For this process, samples were digested with HNO3 for 2 h in a digester block between 90 and 120 degrees C, using the open system with the cold finger. The use of the cold finger system was efficient with similar results to those expected for CRMs for mercury (Hg) concentrations. For the open system, loss of analyte was observed when the digestion temperature was increased. The limit of detection (LOD) was 0.08 mu g L-1. The digestion procedure using cold finger in an open system is useful, at boiling point solution temperature, safe and simple for Hg determination in biological samples. Moreover, it can be used as an alternative to microwave-assisted digestion. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:5 / 9
页数:5
相关论文
共 9 条
  • [1] Determination of Hg in water and wastewater samples by CV-AAS following on-line preconcentration with silver trap
    Mousavi, H. Zavvar
    Asghari, Alireza
    Shirkhanloo, Hamid
    JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 65 (09) : 935 - 939
  • [2] Determination of Hg in water and wastewater samples by CV-AAS following on-line preconcentration with silver trap
    H. Zavvar Mousavi
    Alireza Asghari
    Hamid Shirkhanloo
    Journal of Analytical Chemistry, 2010, 65 : 935 - 939
  • [3] The Utilization of Nitrogen Gas as a Carrier Gas in the Determination of Hg Ions Using Cold Vapor-Atomic Absorption Spectrophotometer (CV-AAS)
    Panggabean, Aman Sentosa
    Pasaribu, Subur P.
    Kristiana, Farida
    INDONESIAN JOURNAL OF CHEMISTRY, 2018, 18 (02) : 279 - 285
  • [4] VALIDATION OF AN ANALYTICAL METHOD FOR THE DETERMINATION OF TOTAL MERCURY IN URINE SAMPLES USING COLD VAPOR ATOMIC ABSORPTION SPECTROMETRY (CV-AAS). CASE STUDY
    Guilhen, Sabine Neusatz
    Faustino Pires, Maria Apareeida
    Keiko Dantas, Elizabeth Sonoda
    Xavier, Fernanda Villibor
    QUIMICA NOVA, 2010, 33 (06): : 1285 - 1290
  • [5] A new on-line version of the gold amalgamation trap for interference-free determination of Hg0 in crude oil and related products by Zeeman CV-AAS
    Pontes, Fernanda Veronesi M.
    Carneiro, Manuel C.
    Vaitsman, Delmo S.
    Monteiro, Maria Ines C.
    Neto, Arnaldo A.
    de Souza, Evelyn da M. F.
    Tristao, Maria Luiza B.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (10) : 1794 - 1798
  • [6] New Design of Mini PTFE Vessels for Sample Preparation in Micro Scale: Determination of Cd, K, Mg and Na in Biological Sample
    Oliz, Camila M.
    Souza, Alexander O.
    Pereira, Camila C.
    Oliveira, Richard M.
    Medina, Aline L.
    Vieira, Mariana A.
    Ribeiro, Anderson S.
    Nunes, Adriane M.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2017, 28 (10) : 1953 - 1959
  • [7] New Design Valve in Flow Injection System for the Determination of Pb(II) in Biological and Environmental Samples
    Jassim, Thekrayat Joodi
    Taresh, Raisan Kadhim
    INDONESIAN JOURNAL OF CHEMISTRY, 2023, 23 (04) : 1129 - 1137
  • [8] Sample preparation methods for determination of Cd, Pb and Sn in meat samples by GFAAS: use of acid digestion associated with a cold finger apparatus versus solubilization methods
    Oreste, Eliezer Quadro
    de Oliveira, Richard Macedo
    Nunes, Adriane Medeiros
    Vieira, Mariana Antunes
    Ribeiro, Anderson Schwingel
    ANALYTICAL METHODS, 2013, 5 (06) : 1590 - 1595
  • [9] Cold finger with semi closed reflux system for sample preparation aiming at Al, Ca, Cr, Cu, Fe, K, Mg, Mn, Ni, V and Zn determination in Drinking Water Treatment Sludge by MIP OES
    Kleemann, Natiele
    Torres, Daiane Placido
    Ribeiro, Anderson Schwingel
    Bamberg, Adilson Luis
    ANALYTICA CHIMICA ACTA, 2020, 1096 : 9 - 17