Comprehensive analysis of a novel power and cooling cogeneration system based on organic Rankine cycle and ejector refrigeration cycle

被引:23
|
作者
Yu, Wei [1 ]
Wang, Huitao [1 ]
Ge, Zhong [2 ]
机构
[1] Kunming Univ Sci & Technol, Fac Met & Energy Engn, Kunming 650093, Yunnan, Peoples R China
[2] Yunnan Univ, Sch Architecture & Planning, Kunming 650091, Yunnan, Peoples R China
基金
美国国家科学基金会;
关键词
Power and cooling cogeneration; Organic Rankine cycle; Ejector refrigeration cycle; Parametric analysis; Optimization; Low-grade heat utilization;
D O I
10.1016/j.enconman.2021.113898
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel combined power and cooling system based on the organic Rankine cycle and the ejector refrigeration cycle for highly efficient utilization of low-grade heat is presented, in which the endothermic process adopts a dual-pressure evaporation approach and the two vapor generators are connected in series. A mathematical model is developed to evaluate the system thermodynamic and exergoeconomic characteristics. The effects of key parameters on system performance are evaluated. Results show that a higher low-pressure evaporation temperature and a higher vapor fraction at the low-pressure vapor generator are conducive to increasing the system cooling output. An optimal high-pressure evaporation temperature exists that gives the maximum exergy efficiency and the minimum sum unit cost of product. Compared with the net power output of the system, the cooling output is more sensitive to the variation of condensation temperature. Among the system components, the ejector has the highest exergy destruction rate and the lowest exergy efficiency. Furthermore, optimization of the system's performance and working fluid selection for fixed cooling outputs was conducted. The results show that reducing the exergy destruction in the endothermic process is the key to improving system performance, while perfluoropropane was found to be the most suitable working fluid for the proposed system. In the cooling output range of 300-700 kW, a minimum sum unit cost of product of 45.79-58.87 $/MWh can be achieved, and corresponding ranges of net power output, energy efficiency and exergy efficiency are 614.93-430.58 kW, 14.32-19.25%, and 32.3-22.62%, respectively. Finally, the performance of the proposed system is compared with two typical systems for a cooling output range of 300-700 kW. The results show that the sum unit cost of product is reduced by 7.9-11.1%, and the net power output increased by 23.6-40.6% compared with the system with parallel vapor generators. Compared to the system with the ejector installed after the turbine, the sum unit cost of product is increased by 9.16-13.28%, and the net power output is increased by 129.73-118.38%.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Exergoeconomic and Exergoenvironmental Analysis of a Novel Power and Cooling Cogeneration System Based on Organic Rankine Cycle and Ejector Refrigeration Cycle
    Tao, Jinke
    Wang, Huitao
    Wang, Jianjun
    Feng, Chaojun
    [J]. ENERGIES, 2022, 15 (21)
  • [2] Performance analysis of cogeneration systems based on micro gas turbine (MGT), organic Rankine cycle and ejector refrigeration cycle
    Bo, Zemin
    Zhang, Kai
    Sun, Peijie
    Lv, Xiaojing
    Weng, Yiwu
    [J]. FRONTIERS IN ENERGY, 2019, 13 (01) : 54 - 63
  • [3] Performance analysis of cogeneration systems based on micro gas turbine (MGT), organic Rankine cycle and ejector refrigeration cycle
    Zemin Bo
    Kai Zhang
    Peijie Sun
    Xiaojing Lv
    Yiwu Weng
    [J]. Frontiers in Energy, 2019, 13 : 54 - 63
  • [4] Thermoeconomic analysis of a novel combined cooling, heating and power system based on solar organic Rankine cycle and cascade refrigeration cycle
    Aghaziarati, Zeinab
    Aghdam, Abolfazl Hajizadeh
    [J]. RENEWABLE ENERGY, 2021, 164 : 1267 - 1283
  • [5] A novel configuration of ejector refrigeration cycle coupled with organic Rankine cycle for transformer and space cooling applications
    Sanaye, Sepehr
    Refahi, Amirhossein
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 115 : 191 - 208
  • [6] Performance analysis of a combined organic Rankine cycle and vapor compression cycle for power and refrigeration cogeneration
    Kim, Kyoung Hoon
    Perez-Blanco, Horacio
    [J]. APPLIED THERMAL ENGINEERING, 2015, 91 : 964 - 974
  • [7] Thermodynamic analysis of solar tower collector integrated with steam Rankine cycle, organic Rankine cycle and absorption refrigeration cycles for cogeneration of power and cooling
    Siddiqui, Mohd Asjad
    Khan, T. M. Yunus
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2024, 43 (03) : 229 - 250
  • [8] Off-design performance analysis of a power-cooling cogeneration system combining a Kalina cycle with an ejector refrigeration cycle
    Du, Yang
    Dai, Yiping
    [J]. ENERGY, 2018, 161 : 233 - 250
  • [9] Evaluation of ejector performance for an organic Rankine cycle combined power and cooling system
    Zhang, Kun
    Chen, Xue
    Markides, Christos N.
    Yang, Yong
    Shen, Shengqiang
    [J]. APPLIED ENERGY, 2016, 184 : 404 - 412
  • [10] Thermodynamic performance analysis a power and cooling generation system based on geothermal flash, organic Rankine cycles, and ejector refrigeration cycle; application of zeotropic mixtures
    Wang, Nan
    Zhang, Su
    Fei, Zhibin
    Zhang, Wei
    Shao, Limin
    Sardari, Farshid
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 40 (40)