Needles used for spinal anesthesia

被引:19
|
作者
Tsen, Lawrence C. [1 ]
Hepner, David L. [1 ]
机构
[1] Harvard Univ, Sch Med, Dept Anesthesiol Perioperat & Pain Med, Boston, MA 02115 USA
关键词
cerebrospirial fluid; epidural blood patch; postdural puncture headache; spinal anesthesia; spinal needles;
D O I
10.1586/17434440.3.4.499
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Since the discovery of spinal anesthesia in 1885 by J Leonard Corning, spinal needles have been modified to simplify their use and minimize complications. Needle design variables, such as diameter, tip design and orifice location, have been altered to enable rapid flow of cerebral spinal fluid (CSF) and injected medications, yet simultaneously limit dural trauma and loss of CSF. CSF loss can result in a severe postdural puncture headache (PDPH). Blunt pencil-point tip needles have been observed to cause a lower incidence of PDPH than similar sized sharp, cuffing tip needles. Smaller diameter needles are also associated with a lower incidence of PDPH. A recent alteration in spinal needles is not to the needle per se, but rather the microcatheters placed through them; currently used in Europe, such catheters are again being evaluated in the USA. Further advancements in spinal needles will most likely involve some of the design elements previously altered, as well as new features not yet recognized as important at this time.
引用
收藏
页码:499 / 508
页数:10
相关论文
共 50 条
  • [1] Comparison of commonly used spinal needles
    Sharma, S
    Philip, J
    Lacour, T
    Perez, B
    Slaymaker, E
    Weidner, C
    Wiley, J
    Yamanouchi, K
    Sidawi, J
    Wallace, D
    ANESTHESIA AND ANALGESIA, 1999, 88 (02): : U171 - U171
  • [2] CRITICAL EVALUATION OF DISPOSABLE SPINAL ANESTHESIA NEEDLES
    DIGIOVANNI, AJ
    ANESTHESIOLOGY, 1971, 34 (01) : 88 - +
  • [3] SPINAL-ANESTHESIA WITH EXTREMELY FINE NEEDLES
    DITTMANN, M
    RENKL, F
    ANESTHESIOLOGY, 1989, 70 (06) : 1035 - 1036
  • [4] A comparison of three different needles used for spinal anesthesia in terms of squamous epithelial cell transport risk
    Cigdem, Unal Kantekin
    Sevinc, Sahin
    Esef, Bolat
    Sureyya, Ozturk
    Muzaffer, Gencer
    Akif, Demirel
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2017, 67 (05): : 468 - 471
  • [5] CLINICAL CHARACTERISTICS OF COMMONLY USED SPINAL NEEDLES
    CARSON, DF
    SERPELL, MG
    ANAESTHESIA, 1995, 50 (06) : 523 - 525
  • [6] CLINICAL CHARACTERISTICS OF COMMONLY USED SPINAL NEEDLES
    PARRY, M
    BAWA, GPS
    FERNANDO, R
    ANAESTHESIA, 1995, 50 (12) : 1095 - 1096
  • [7] The evolution of combined spinal-epidural anesthesia needles
    Eldor, J
    REGIONAL ANESTHESIA, 1997, 22 (03) : 294 - 296
  • [8] SMALL BORE SPINAL NEEDLES IN VAGINAL DELIVERY ANESTHESIA
    ARNOLD, DC
    NELSON, HB
    PACIFIC MEDICINE AND SURGERY, 1966, 74 (04): : 220 - &
  • [9] SPINAL-ANESTHESIA IN OBSTETRICS - HEADACHE AND SPECIAL NEEDLES
    THOMAS, DV
    ANAESTHESIA, 1990, 45 (12) : 1100 - 1100
  • [10] VOLTAGE FIELDS SURROUNDING NEEDLES USED IN REGIONAL ANESTHESIA
    JONES, RP
    DEJONGE, M
    SMITH, BE
    BRITISH JOURNAL OF ANAESTHESIA, 1992, 68 (05) : 515 - 518