BIPM comparison BIPM.RI(II)-K1.Cr-51 of the activity measurements of the radionuclide 51Cr

被引:0
|
作者
Ratel, G. [1 ]
Michotte, C. [1 ]
机构
[1] Bur Int Poids & Mesures, Pavillon Breteuil, F-92312 Sevres, France
关键词
D O I
10.1088/0026-1394/40/1A/06008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Since 1977, eight national metrology institutes and three other laboratories have submitted 26 samples of known activity of Cr-51 to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures. The activities ranged from about 3 MBq to 90 MBq. The degrees of equivalence between each equivalent activity measured in the SIR and the key comparison reference value (KCRV) have been calculated and the results are given in the form of a matrix for nine laboratories. A graphical presentation is also given.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Update of the BIPM comparison BIPM.RI(II)-K1.Cr-51 of activity measurements of the radionuclide 51Cr to include the 2012 result of the KRISS (Rep. of Korea), the 2022 result of the POLATOM (Poland), and to link the 2022 EURAMET.RI(II)-K2.Cr-51 comparison
    Michotte, C.
    Courte, S.
    Coulon, R.
    Nonis, M.
    Judge, S.
    Park, Tae Soon
    Lee, Jong-Man
    Lee, K.B.
    Ziemek, T.
    Listkowska, A.
    Lech, E.
    Saganowski, P.
    Marganiec-Galązka, J.
    Broda, R.
    Metrologia, 2024, 61 (1 A)
  • [2] BIPM comparison BIPM.RI(II)-K1.In-111 of activity measurements of the radionuclide 111In
    Ratel, G.
    Michotte, C.
    METROLOGIA, 2003, 40
  • [3] BIPM comparison BIPM.RI(II)-K1.Rn-222 of activity measurements of the radionuclide 222Rn
    Ratel, G.
    Michotte, C.
    Bochud, F. O.
    METROLOGIA, 2004, 41
  • [4] BIPM comparison BIPM.RI(II)-K1.Zn-65 of activity measurements of the radionuclide 65Zn
    Ratel, G.
    Michotte, C.
    METROLOGIA, 2004, 41
  • [5] BIPM comparison BIPM.RI(II)-K1.Hg-203 of activity measurements of the radionuclide 203Hg
    Ratel, G.
    Michotte, C.
    METROLOGIA, 2003, 40
  • [6] BIPM comparison BIPM.RI(II)-K1.Na-24 of activity measurements of the radionuclide 24Na
    Ratel, G.
    Michotte, C.
    METROLOGIA, 2003, 40
  • [7] BIPM comparison BIPM.RI(II)-K1.TI-201 of activity measurements of the radionuclide 201TI
    Ratel, G.
    Michotte, C.
    METROLOGIA, 2004, 41
  • [8] BIPM comparison BIPM.RI(II)-K1.Co-57 of activity measurements of the radionuclide 57Co
    Ratel, G.
    Michotte, C.
    METROLOGIA, 2003, 40
  • [9] BIPM comparison BIPM.RI(II)-K1.Na-22 of activity measurements of the radionuclide 22Na
    Ratel, G.
    Michotte, C.
    METROLOGIA, 2003, 40
  • [10] BIPM comparison BIPM.RI(II)-K1.Am-243 of the activity measurements of the radionuclide 243Am
    Ratel, G.
    Michotte, C.
    Woods, M. J.
    METROLOGIA, 2003, 40