Retinal Image Registration Using Geometrical Features

被引:25
|
作者
Gharabaghi, Sara [1 ]
Daneshvar, Sabalan [1 ]
Sedaaghi, Mohammad Hossein [1 ]
机构
[1] Sahand Univ Technol, Fac Elect Engn, Tabriz, Iran
关键词
Image registration; Retinal images; Affine moment invariant (AMI); Affine transformation; OPTIC DISC; MODEL; ALGORITHM; FUSION; FOVEA;
D O I
10.1007/s10278-012-9501-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, we have introduced an accurate retinal images registration method using affine moment invariants (AMI's) which are the shape descriptors. First, some closed-boundary regions are extracted in both reference and sensed images. Then, AMI's are computed for each of those regions. The centers of gravity of three pairs of regions which have the minimum of distances are selected as the control points. The region matching is performed by the distance measurements of AMI's. The evaluation of region matching is performed by comparing the angles of three triangles which are built on these three-point pairs in reference and sensed images. The parameters of affine transform can be computed using these three pairs of control points. The proposed algorithm is applied on the valid DRIVE database. In general (for the case, each sensed image is produced by rotating, scaling, and translating the reference image with different angles, scale factors, and translation factors), the success rate and accuracy is 95 and 96 %, respectively.
引用
收藏
页码:248 / 258
页数:11
相关论文
共 50 条
  • [1] Retinal Image Registration Using Geometrical Features
    Sara Gharabaghi
    Sabalan Daneshvar
    Mohammad Hossein Sedaaghi
    [J]. Journal of Digital Imaging, 2013, 26 : 248 - 258
  • [2] Hybrid Retinal Image Registration Using Mutual Information and Salient Features
    Ju, Jaeyong
    Loew, Murray
    Ku, Bonhwa
    Ko, Hanseok
    [J]. IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2016, E99D (06): : 1729 - 1732
  • [3] Multimodal cardiac image fusion by geometrical features registration and warping
    Santarelli, MF
    Positano, V
    Marcheschi, P
    Landini, L
    Marzullo, P
    Benassi, A
    [J]. COMPUTERS IN CARDIOLOGY 2001, VOL 28, 2001, 28 : 277 - 280
  • [4] Retinal Image Registration Based on Features of Vessel-Segmented Image
    She, Yaoying
    Zhou, Mei
    Li, Qingli
    Sun, Li
    [J]. 2021 14TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2021), 2021,
  • [5] Geometrical SAR image registration
    Sansosti, Eugenio
    Berardino, Paolo
    Manunta, Michele
    Serafino, Francesco
    Fornaro, Gianfranco
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2006, 44 (10): : 2861 - 2870
  • [6] Retinal Image Registration using Phase Correlation
    Kolar, Radim
    Sikula, Viktor
    Base, Michal
    [J]. ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, 2010, : 244 - 252
  • [7] Retinal image registration using control points
    Heneghan, C
    Maguire, P
    Ryan, N
    de Chazal, P
    [J]. 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 349 - 352
  • [8] Retinal Image Registration Using Bifurcation Structures
    Chen, Li
    Xiang, Yang
    Chen, YaoJie
    Zhang, XiaoLong
    [J]. 2011 18TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2011,
  • [9] Multiple Image Features-Based Retinal Image Registration Using Global and Local Geometric Structure Constraints
    Bi, Dongsheng
    Yu, Rui
    Li, Mengya
    Yang, Yang
    Yang, Kun
    Ong, Sim Heng
    [J]. IEEE ACCESS, 2019, 7 : 133017 - 133029
  • [10] Super-speed up robust features image geometrical registration algorithm
    Na, Yan
    Liao, Mengmeng
    Jung, Cheolkon
    [J]. IET IMAGE PROCESSING, 2016, 10 (11) : 848 - 864