Refractive accuracy after intraocular lens implantation in pediatric cataract

被引:6
|
作者
Long, Tan [1 ,2 ]
Huang, Yu-Sen [1 ]
Xie, Li-Xin [1 ]
机构
[1] Shandong Eye Inst, Qingdao 266071, Peoples R China
[2] Wuhan Univ, Peoples Hosp, Dept Ophthalmol, Wuhan 430060, Hubei Province, Peoples R China
关键词
cataract; children; refraction; intraocular lens; MYOPIC SHIFT; POWER CALCULATION; SURGERY; OUTCOMES; CHILDREN; EYE; PSEUDOPHAKIA; GROWTH;
D O I
10.3980/j.issn.2222-3959.2012.04.13
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To analyze the factors that influence the prediction error (PE). after intraocular lens (IOL) implantation in pediatric cataract. METHODS: The medical records of cataract patients of no more than 14 years old who had primary IOL implantation were reviewed from 2006 to 2010. The PE, absolute value of PE (APE), and predictability between in different axial length, mean corneal curvature, corneal astigmatism, and age at the surgery were analyzed. RESULTS: Seventy-five children (119 eyes) were included, with a mean age of (5.09 +/- 2.54) years. At the follow-up of (1.19 +/- 0.69) months, the mean postoperative PE was (-0.22 +/- 1.12) D, and APE was (0.87 +/- 0.73)D. The PE in eyes with an axial length > 20mm but <= 22mm were significantly under-corrected than that in eyes with longer axis, and the APE in eyes with an axial length <= 20mm was more obvious compared with the others. The correlations between PE and axial length, as well as corneal astigmatism, and between APE and axial length were significant. The predictability was significantly poorer in the eyes with an axial length <= 20mm than the others. CONCLUSION: The axial length is closely related with the PE after IOL implantation in pediatric cataract patients, especially when it is <= 20mm, PE is more significant. The formula that is more suitable to very short axial length should be explored.
引用
收藏
页码:473 / 477
页数:5
相关论文
共 50 条
  • [2] Accuracy of toric intraocular lens implantation in cataract and refractive surgery
    Visser, Nienke
    Berendschot, Tos T. J. M.
    Bauer, Noel J. C.
    Jurich, Jessica
    Kersting, Oliver
    Nuijts, Rudy M. M. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (08): : 1394 - 1402
  • [3] Refractive changes after pediatric intraocular lens implantation
    Enyedi, LB
    Peterseim, MW
    Freedman, SF
    Buckley, EG
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (06) : 772 - 781
  • [4] Refractive changes after pediatric intraocular lens implantation
    Basti, S
    Jensen, A
    Greenwald, MJ
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (03) : 394 - 394
  • [5] Accuracy of biometry in pediatric cataract extraction with primary intraocular lens implantation
    Moore, Daniel B.
    Ben Zion, Itay
    Neely, Daniel E.
    Plager, David A.
    Offier, Susan
    Sprunger, Derek T.
    Roberts, Gavin J.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11): : 1940 - 1947
  • [6] Postoperative Refractive Errors Following Pediatric Cataract Extraction with Intraocular Lens Implantation
    Indaram, Maanasa
    VanderVeen, Deborah K.
    [J]. SEMINARS IN OPHTHALMOLOGY, 2018, 33 (01) : 51 - 58
  • [8] Visual and refractive outcomes of new intraocular lens implantation after cataract surgery
    Bhupesh Singh
    Sourabh Sharma
    Neha Bharti
    Dharitri Samantrey
    Dadan J. Paandey
    Sudhank Bharti
    [J]. Scientific Reports, 12
  • [9] Visual and refractive outcomes of new intraocular lens implantation after cataract surgery
    Singh, Bhupesh
    Sharma, Sourabh
    Bharti, Neha
    Samantrey, Dharitri
    Paandey, Dadan J.
    Bharti, Sudhank
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [10] Multifocal intraocular lens implantation in pediatric cataract surgery
    Jacobi, PC
    Dietlein, TS
    Konen, W
    [J]. OPHTHALMOLOGY, 2001, 108 (08) : 1375 - 1380