Position change during colonoscope withdrawal increases polyp and adenoma detection in the right but not in the left side of the colon: results of a randomized controlled trial

被引:27
|
作者
Ball, Alex J. [1 ]
Johal, Shawinder S. [1 ]
Riley, Stuart A. [1 ]
机构
[1] Sheffield Teaching Hosp, No Gen Hosp, Dept Gastroenterol, Sheffield S5 7AU, S Yorkshire, England
关键词
TO-BACK COLONOSCOPIES; COLORECTAL-CANCER; MISS RATE; PATIENT POSITION; QUALITY; RATES; RISK; PROTECTION; DEATH;
D O I
10.1016/j.gie.2015.01.035
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: It has been suggested that changing patient position during colonoscope withdrawal increases adenoma detection. The results of previous studies have been conflicting. Objective: To evaluate whether routine position change during colonoscope withdrawal improves polyp detection. Design: Randomized, 2-way, crossover study. Setting: Teaching hospital. Patients: A total of 130 patients attending for diagnostic colonoscopy. Interventions: Patients undergoing colonoscopy had each colon segment examined twice: the right side of the colon (cecum to hepatic flexure) in the supine and left lateral position and the left side of the colon (splenic flexure and descending colon) in the supine and right lateral position. The transverse colon was examined twice in the supine position. Main Outcome Measurements: The primary outcome measure was the polyp detection rate (>= 1 polyp) per colon segment. Secondary outcome measures included the number and proportion of patients with >= 1 adenoma in each segment and adequacy of luminal distension (1 = total collapse and 5 = no collapse). Results: Examination of the right side of the colon in the left lateral position significantly improved polyp detection (26.2% vs 17.7%; P = .01) and luminal distension (mean = 4.0 vs 3.5; P < .0001). Position change did not improve polyp detection in the left side of the colon (5.4% vs 4.6%; P = .99). There was no significant correlation between luminal distension and polyp detection in the right side of the colon (r = .03). Limitations: Single center and open study design. Conclusion: Examining the right side of the colon in the left lateral position increased polyp detection compared with examination in the supine position. Polyp detection in the left side of the colon was similar in the right lateral and supine positions.
引用
收藏
页码:488 / 494
页数:7
相关论文
共 50 条
  • [1] Effect of Dynamic Position Changes on Adenoma Detection During Colonoscope Withdrawal: A Randomized Controlled Multicenter Trial
    Lee, Seung-Woo
    Chang, Jae Hyuck
    Ji, Jeong-Seon
    Maeong, Il Ho
    Cheung, Dae Young
    Kim, Joon Sung
    Cho, Young-Seok
    Chung, Wook-Jin
    Lee, Bo-In
    Kim, Sang-Woo
    Kim, Byung-Wook
    Choi, Hwang
    Choi, Myung-Gyu
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2016, 111 (01): : 63 - 69
  • [2] A randomized controlled trial assessing the effect of prescribed patient position changes during colonoscope withdrawal on adenoma detection
    Ou, George
    Kim, Edward
    Lakzadeh, Pardis
    Tong, Jessica
    Enns, Robert
    Ramji, Alnoor
    Whittaker, Scott
    Ko, Hin Hin
    Bressler, Brian
    Halparin, Lawrence
    Lam, Eric
    Amar, Jack
    Telford, Jennifer
    GASTROINTESTINAL ENDOSCOPY, 2014, 80 (02) : 277 - +
  • [3] Dynamic patient position changes during colonoscope withdrawal increase adenoma detection: a randomized, crossover trial
    East, James E.
    Bassett, Paul
    Arebi, Naila
    Thomas-Gibson, Siwan
    Guenther, Thomas
    Saunders, Brian P.
    GASTROINTESTINAL ENDOSCOPY, 2011, 73 (03) : 456 - 463
  • [4] Insertion water exchange increases right colon adenoma and hyperplastic polyp detection rates during withdrawal
    Cadoni, Sergio
    Falt, Premysl
    Sanna, Stefano
    Argiolas, Mariangela
    Fanari, Viviana
    Gallittu, Paolo
    Liggi, Mauro
    Mura, Donatella
    Porcedda, Maria L.
    Smajstrla, Vit
    Erriu, Matteo
    Leung, Felix W.
    DIGESTIVE AND LIVER DISEASE, 2016, 48 (06) : 638 - 643
  • [5] Patient position changes during colonoscope withdrawal increase adenoma detection: A randomised, crossover trial
    East, J. E.
    Bassett, P.
    Stavrinidis, M.
    Arebi, N.
    Thomas-Gibson, S.
    Guenther, T.
    Saunders, B. P.
    GUT, 2008, 57 : A4 - A5
  • [6] Cimetropium bromide does not improve polyp and adenoma detection during colonoscope withdrawal A randomized, double-blind, placebo-controlled study
    Jung, Peel
    Park, Su B.
    Kim, Hyung W.
    Kang, Dae H.
    Choi, Cheol W.
    Kim, Su J.
    Nam, Hyeong S.
    Ryu, Dae G.
    Hong, Joung B.
    Kim, Dong J.
    MEDICINE, 2018, 97 (25)
  • [7] Withdrawal Time Affects Polyp and Diverticulum Detection on the Right-side Colon
    Kajiwara, Haruka
    Yamaji, Yutaka
    Sugimoto, Takafumi
    Yamada, Atsuo
    Watabe, Hirotsugu
    Yoshida, Haruhiko
    Omata, Masao
    Koike, Kazuhiko
    HEPATO-GASTROENTEROLOGY, 2012, 59 (113) : 108 - 111
  • [8] Polyp detection rate is improved with position changes during colonoscope withdrawal: A randomised, crossover trial, mid-point analysis
    East, James E.
    Stavrinidis, Mari
    Arebi, Naila
    Palmer, Nicky
    Bassett, Paul
    Saunders, Brian P.
    GASTROINTESTINAL ENDOSCOPY, 2007, 65 (05) : AB112 - AB112
  • [9] Polyp detection rate is improved with position changes during colonoscope withdrawal: A randomised, crossover trial, mid-point analysis
    East, J. E.
    Stavrinidis, M.
    Arebi, N.
    Palmer, N.
    Bassett, P.
    Saunders, B. P.
    GUT, 2007, 56 : A90 - A90
  • [10] Position changes improve visibility during colonoscope withdrawal: a randomized, blinded, crossover trial
    East, James E.
    Suzuki, Noriko
    Arebi, Naila
    Bassett, Paul
    Saunders, Brian P.
    GASTROINTESTINAL ENDOSCOPY, 2007, 65 (02) : 263 - 269