An innovative electromagnetics sensor for partial discharge detection in cable joints and terminations

被引:0
|
作者
Huang, Zhiwei [1 ]
Zheng, Zhong [1 ]
Feng, Wei [1 ]
Chen, Xiaoyun [1 ]
Chen, Lihua [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing Key Lab High Voltage & EMC, Beijing 102206, Peoples R China
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The application of cross-links at the cable joints and the arrester-groundings at the cable terminals undoubtedly reduces the ground potential and the sheath current in a cable system, however, such configuration builds an open circuit in the grounding conductor and stops the partial discharges (PD) pulses to travel. Thus very few pulse energy goes into the grounding wire, which is an industrial accepted checkpoint for PD defects through conventional sensors such as high frequency current transformers. To solve the problem, this paper introduced an innovative broadband PD sensor by using a capacitive jumper to bridge the PD propagation path. In this way, the problem of impedance mismatch at PD frequency is avoided, while an open circuit is maintained at power frequency. The sensor is tested in the laboratory with an oscilloscope for its sensitivity and detection bandwidth, while the latter reaches about 200 kHz similar to 87MHz. Such sensor was tested in a real 110 kV cable and shown the convenience and effectiveness in PD detection.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Recognition of partial discharge defects in cable terminations
    Lee, Chang-Hsing
    Lin, Yu-Chih
    Chiu, Min-Yen
    Huang, Chih-Hsien
    Yen, Shih-Shong
    Haeng, Chiang
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1242 - +
  • [2] An Innovative Sensor for Cable Joint Monitoring and Partial Discharge Localization
    Barbieri, Luca
    Villa, Andrea
    Malgesini, Roberto
    Palladini, Daniele
    Laurano, Christian
    [J]. ENERGIES, 2021, 14 (14)
  • [3] Detection and localization of partial discharge in high voltage power cable joints
    Kheirmand, A
    Leijon, M
    Tornkvist, C
    [J]. PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS - ICSD '98, 1998, : 145 - 148
  • [4] Radio-Frequency Detection of Partial Discharge in Power Cable Joints
    Hu, Xiao
    Yang, Shaocai
    Du, Qing
    Chen, Xiangrong
    Tang, Fuxin
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (01) : 317 - 324
  • [5] Design of Hilbert Fractal Antenna for Partial Discharge Detection in Cable Joints
    Yin, Yang
    Li, Shi-qiang
    Yan, Xiao-heng
    Zhao, Xiao-he
    Lv, Zhi-guang
    Liu, Yi-miao
    [J]. PROCEEDINGS OF 2023 INTERNATIONAL CONFERENCE ON WIRELESS POWER TRANSFER, VOL 2, ICWPT 2023, 2024, 1159 : 19 - 27
  • [6] Comparison of Acoustic and Electrical Partial Discharge Measurements on Cable Terminations
    Cselko, Richard
    Tamus, Zoltan Adam
    Szabo, Attila
    Berta, Istvan
    [J]. CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [7] Partial discharge detection in XLPE power cable with CT sensor
    Luo, JH
    Feng, J
    Yuan, J
    Ma, CJ
    Qiu, YC
    [J]. ICSD '01: PROCEEDINGS OF THE 2001 IEEE 7TH INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, 2001, : 400 - 403
  • [8] Partial discharge measurement in transmission-class cable terminations
    Ahmed, N
    Morel, O
    Srinivas, N
    [J]. 1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 2 - 7
  • [9] Analysis of Partial Discharge in Underground Cable Joints
    Rajalakshmi, B.
    Kalaivani, L.
    [J]. 2015 INTERNATIONAL CONFERENCE ON INNOVATIONS IN INFORMATION, EMBEDDED AND COMMUNICATION SYSTEMS (ICIIECS), 2015,
  • [10] NEW PARTIAL DISCHARGE DETECTION METHOD FOR LIVE UHV EHV CABLE JOINTS
    FUKUNAGA, K
    TAN, M
    TAKEHANA, H
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1992, 27 (03): : 669 - 674