New cyclodextrin-based ion-selective electrodes for determining activity coefficients of biologically important onium ions

被引:0
|
作者
Barriada, JL
Covington, AK
Kataky, R
机构
[1] Univ Durham, Dept Chem, Durham DH1 3LE, England
[2] Univ A Coruna, Fac Sci, Dept Fundamental & Ind Chem, La Coruna 15071, Spain
[3] Newcastle Univ, Dept Chem, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
ion-selective electrodes; onium ions; choline; acetylcholine; acetyl-beta-choline; methacholine; cyclodextrin; activity coefficients; osmotic coefficients;
D O I
10.1023/A:1022682915813
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Ion-selective electrodes (ISEs), apart from fluoride, calcium, and a few others, have not often been used to obtain thermodynamic information on electrolytes. Here, novel cyclodextrin-based ISEs are used to determine activity coefficients of some onium chlorides in aqueous solution. Cyclodextrins, rendered lipophilic by alkylation, have been incorporated into polymeric membranes and used as ionophores in ISEs for sensing the substituted ammonium (onium) ions, choline, acetylcholine, and acetyl-beta-methylcholine. Potentiometric measurements using these cyclodextrin-based ISEs allow the determination of ratios of activity coefficients in solutions. Choosing one solution as reference and using a theoretical model (e.g., Pitzer equations), it is possible to evaluate activity coefficients of individual solutions. Results for choline chloride compare well with limited data in the literature. This is the first time, that ISEs have been used to measure activity coefficients of biologically important ions.
引用
收藏
页码:555 / 565
页数:11
相关论文
共 50 条
  • [1] New Cyclodextrin-Based Ion-Selective Electrodes for Determining Activity Coefficients of Biologically Important Onium Ions
    J. L. Barriada
    A. K. Covington
    R. Kataky
    Journal of Solution Chemistry, 1999, 28 : 555 - 565
  • [2] Local Anesthetics Measured by Lipophilic β-Cyclodextrin-Based Ion-Selective Electrodes
    Department of Chemistry, University of Durham, South Road, Durham, DH1 3LE, United Kingdom
    Electroanalysis, 6 (585-590):
  • [3] DETERMINATION OF MEAN ACTIVITY-COEFFICIENTS WITH ION-SELECTIVE ELECTRODES
    BATES, RG
    DICKSON, AG
    GRATZL, M
    HRABECZYPALL, A
    LINDNER, E
    PUNGOR, E
    ANALYTICAL CHEMISTRY, 1983, 55 (08) : 1275 - 1280
  • [4] ION-SELECTIVE ELECTRODES FOR THE DETERMINATION OF MEAN ACTIVITY-COEFFICIENTS
    PUNGOR, E
    HRABECZYPALL, A
    LINDNER, E
    GRATZL, M
    BATES, RG
    MAGYAR KEMIAI FOLYOIRAT, 1983, 89 (08): : 337 - 345
  • [5] Determination of ion activity coefficients in aqueous solutions with the aid of ion-selective electrodes
    Schneider, AC
    Pasel, C
    Luckas, M
    Schmidt, KG
    Herbell, JD
    CHEMIE INGENIEUR TECHNIK, 2003, 75 (03) : 244 - 249
  • [6] Ion-Selective Electrodes: Selectivity Coefficients for Interfering Ions of the Opposite Charge Sign
    Honig, Madeline L.
    Buhlmann, Philippe
    ACS SENSORS, 2025,
  • [7] DIFFUSION OF IONS IN VARIABLE-CHARGE SOILS .1. DETERMINING DIFFUSION-COEFFICIENTS WITH MINIATURE ION-SELECTIVE ELECTRODES
    WANG, EJ
    YU, TR
    SOIL SCIENCE, 1989, 147 (01) : 34 - 39
  • [8] KINETIC CONSIDERATIONS OF ION SELECTIVITY COEFFICIENTS OF ION-SELECTIVE ELECTRODES BASED ON NEUTRAL CARRIERS
    OKADA, T
    HIRATANI, K
    SUGIHARA, H
    ANALYTICA CHIMICA ACTA, 1989, 221 (01) : 117 - 129
  • [9] EVALUATION OF A NEW APPARATUS FOR DETERMINING SODIUM AND POTASSIUM VIA ION-SELECTIVE ELECTRODES
    BORNER, U
    MULLER, H
    HEMPELMANN, G
    ANASTHESIE INTENSIVTHERAPIE NOTFALLMEDIZIN, 1983, 18 (01): : 41 - 44
  • [10] Selectivity coefficients of ion-selective magnesium electrodes used for simultaneous determination of magnesium and calcium ions
    Maj-Zurawska, Magdalena
    Lewenstam, Andrzej
    TALANTA, 2011, 87 : 295 - 301