Improved border sharpness of post-infarct scar by a novel self-navigated free-breathing high-resolution 3D whole-heart inversion recovery magnetic resonance approach

被引:22
|
作者
Rutz, Tobias [1 ,2 ]
Piccini, Davide [3 ,4 ,5 ]
Coppo, Simone [4 ,5 ]
Chaptinel, Jerome [4 ,5 ]
Ginami, Giulia [4 ,5 ]
Vincenti, Gabriella [1 ,2 ]
Stuber, Matthias [4 ,5 ,6 ]
Schwitter, Juerg [1 ,2 ]
机构
[1] Univ Lausanne Hosp, Div Cardiol, Lausanne, Switzerland
[2] Univ Lausanne Hosp, Cardiac MR Ctr, Lausanne, Switzerland
[3] Siemens Healthcare, Adv Clin Imaging Technol, Lausanne, Switzerland
[4] Univ Hosp, Dept Radiol, Lausanne, Switzerland
[5] Univ Lausanne, Lausanne, Switzerland
[6] Ctr Biomed Imaging, Lausanne, Switzerland
来源
基金
瑞士国家科学基金会;
关键词
3D self-navigation; Free-breathing; Whole heart; Scar imaging; Inversion recovery MRI; LATE-GADOLINIUM-ENHANCEMENT; MYOCARDIAL-INFARCTION; VENTRICULAR-TACHYCARDIA; DELAYED ENHANCEMENT; CARDIAC MR; FIBROSIS; SIZE; RECONSTRUCTION; DYSFUNCTION; ANGIOGRAPHY;
D O I
10.1007/s10554-016-0963-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The border zone of post-infarction myocardial scar as identified by late gadolinium enhancement (LGE) has been identified as a substrate for arrhythmias and consequently, high-resolution 3D scar information is potentially useful for planning of electrophysiological interventions. This study evaluates the performance of a novel high-resolution 3D self-navigated free-breathing inversion recovery magnetic resonance pulse sequence (3D-SN-LGE) vs. conventional 2D breath-hold LGE (2D-LGE) with regard to sharpness of borders (S-Border) of post-infarction scar. Patients with post-infarction scar underwent two magnetic resonance examinations for conventional 2D-LGE and high-resolution 3D-SN-LGE acquisitions (both 15 min after 0.2 mmol/kg Gadobutrol IV) at 1.5T. In the prototype 3D-SN-LGE sequence, each ECG-triggered radial steady-state-free-precession read-out segment is preceded by a non-slice-selective inversion pulse. Scar volume and SBorder were assessed on 2D-LGE and matching reconstructed high-resolution 3D-SN-LGE short-axis slices. In 16 patients (four females, 58 +/- 10y) all scars visualized by 2D-LGE could be identified on 3D-SN-LGE (time between 2D-LGE and 3D-SN-LGE 48 +/- 53 days). A good agreement of scar volume by 3D-SN-LGE vs. 2D-LGE was found (Bland-Altman: -3.7 +/- 3.4 ml, correlation: r = 0.987, p < 0.001) with a small difference in scar volume (20.5 (15.8, 35.2) ml vs. 24.5 (20.0, 41.9)) ml, respectively, p = 0.002] and a good intra- and interobserver variability (1.1 +/- 4.1 and -1.1 +/- 11.9 ml, respectively). SBorder of border "scar to non-infarcted myocardium" was superior on 3D-SN-LGE vs. 2D-LGE: 0.180 +/- 0.044 vs. 0.083 +/- 0.038, p < 0.001. Detection and quantification of myocardial scar by 3D-SN-LGE is feasible and accurate in comparison to 2D-LGE. The high spatial resolution of the 3D sequence improves delineation of scar borders.
引用
收藏
页码:1735 / 1744
页数:10
相关论文
共 32 条
  • [1] Improved border sharpness of post-infarct scar by a novel self-navigated free-breathing high-resolution 3D whole-heart inversion recovery magnetic resonance approach
    Tobias Rutz
    Davide Piccini
    Simone Coppo
    Jerome Chaptinel
    Giulia Ginami
    Gabriella Vincenti
    Matthias Stuber
    Juerg Schwitter
    The International Journal of Cardiovascular Imaging, 2016, 32 : 1735 - 1744
  • [2] Border sharpness of scar tissue after myocardial infarction as determined by self-navigated free-breathing isotropic 3D whole-heart inversion recovery magnetic resonance
    Tobias Rutz
    Giulia Ginami
    Davide Piccini
    Jérôme Chaptinel
    Simone Coppo
    Gabriella Vincenti
    Matthias Stuber
    Juerg Schwitter
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [3] Accuracy of self-navigated free-breathing isotropic 3D whole heart inversion recovery magnetic resonance for detection of myocardial infarction
    Tobias Rutz
    Davide Piccini
    Jerome Chaptinel
    Simone Coppo
    Gabriella Vincenti
    Matthias Stuber
    Juerg Schwitter
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [4] Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction
    Stehning, C
    Börnert, P
    Nehrke, K
    Eggers, H
    Stuber, M
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 476 - 480
  • [5] 2D cine vs. 3D self-navigated free-breathing high-resolution whole heart cardiovascular magnetic resonance for aortic root measurements in congenital heart disease
    Nussbaumer, Clement
    Bouchardy, Judith
    Blanche, Coralie
    Piccini, Davide
    Pavon, Anna-Giulia
    Monney, Pierre
    Stuber, Matthias
    Schwitter, Jurg
    Rutz, Tobias
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [6] 2D cine vs. 3D self-navigated free-breathing high-resolution whole heart cardiovascular magnetic resonance for aortic root measurements in congenital heart disease
    Clément Nussbaumer
    Judith Bouchardy
    Coralie Blanche
    Davide Piccini
    Anna-Giulia Pavon
    Pierre Monney
    Matthias Stuber
    Jürg Schwitter
    Tobias Rutz
    Journal of Cardiovascular Magnetic Resonance, 23
  • [7] Coronary artery assessment using self-navigated free-breathing radial whole-heart magnetic resonance angiography in patients with congenital heart disease
    Albrecht, Moritz H.
    Varga-Szemes, Akos
    Schoepf, U. Joseph
    Apfaltrer, Georg
    Xu, Jiaqian
    Jin, Kwang-Nam
    Hlavacek, Anthony M.
    Chowdhury, Shahryar M.
    Suranyi, Pal
    Tesche, Christian
    De Cecco, Carlo N.
    Piccini, Davide
    Stuber, Matthias
    Ginami, Giulia
    Vogl, Thomas J.
    Nutting, Arni
    EUROPEAN RADIOLOGY, 2018, 28 (03) : 1267 - 1275
  • [8] Coronary artery assessment using self-navigated free-breathing radial whole-heart magnetic resonance angiography in patients with congenital heart disease
    Moritz H. Albrecht
    Akos Varga-Szemes
    U. Joseph Schoepf
    Georg Apfaltrer
    Jiaqian Xu
    Kwang-Nam Jin
    Anthony M. Hlavacek
    Shahryar M. Chowdhury
    Pal Suranyi
    Christian Tesche
    Carlo N. De Cecco
    Davide Piccini
    Matthias Stuber
    Giulia Ginami
    Thomas J. Vogl
    Arni Nutting
    European Radiology, 2018, 28 : 1267 - 1275
  • [9] A quantitative comparison between a navigated Cartesian and a self-navigated radial protocol from clinical studies for free-breathing 3D whole-heart bSSFP coronary MRA
    Heerfordt, John
    Stuber, Matthias
    Maillot, Aurelien
    Bianchi, Veronica
    Piccini, Davide
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (01) : 157 - 169
  • [10] Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation
    Moghari, Mehdi H.
    Barthur, Ashita
    Amaral, Maria E.
    Geva, Tal
    Powell, Andrew J.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 181 - 189