Experimental investigations on masonry structures using external prestressing techniques for improving seismic performance

被引:39
|
作者
Ma, Renle [1 ]
Jiang, Lu [1 ]
He, Minjuan [1 ]
Fang, Cheng [2 ]
Liang, Feng [3 ]
机构
[1] Tongji Univ, Dept Bldg Engn, Shanghai 200092, Peoples R China
[2] Univ London Imperial Coll Sci Technol & Med, Dept Civil & Env Engn, London SW7 2AZ, England
[3] Tongji Univ Grp Co Ltd, Architectural Design & Res Inst, Shanghai 200092, Peoples R China
关键词
Masonry structure; Post-tensioned masonry; External prestressing; Multi-level-prestressing; Seismic strengthening; Shaking table test; BEHAVIOR; WALLS; STRENGTH; TESTS;
D O I
10.1016/j.engstruct.2012.04.029
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Based on previous failure characteristics of masonry structures under earthquakes, and due to the fact that a considerable number of masonry structures have been built around the world, a strengthening strategy for improving seismic performance of masonry structures is adopted and justified in this paper, namely, the external prestressing technique. The principle of this strategy is to tension the prestressing tendons located on both sides of the walls in order to increase the in-plane shear strength and simultaneously to improve the out-of-plane bending resistance of masonry walls, thus allowing an overall improvement of masonry structures under seismic loadings. In addition, this strategy enables multi-level-prestressing to be applied to the walls at different floors, thus allowing optimized compressive prestress in the structure along the building height. In order to validate the effectiveness of this technique, shaking table model tests were conducted. The experimental results showed that, after introducing vertical prestressing to the walls with the proposed technique, the failure mode of the tested masonry structures was influenced, and the torsional resistance was improved significantly. Furthermore, the prestressing also improved the energy dissipation capacity of the walls and enhanced the overall stiffness of the masonry structure. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:297 / 307
页数:11
相关论文
共 50 条
  • [1] Experimental Investigation into the Seismic Performance of Fully Grouted Concrete Masonry Walls Using New Prestressing Technology
    Chi, Bin
    Yang, Xu
    Wang, Fenglai
    Zhang, Zhiming
    Quan, Yuhu
    [J]. APPLIED SCIENCES-BASEL, 2019, 9 (20):
  • [2] An Investigative Study for the Seismic Performance of Composite-Reinforced Masonry Wall with Prestressing Technology
    Chi, Bin
    Quan, Yuhu
    Wang, Fenglai
    Yang, Xu
    [J]. BUILDINGS, 2024, 14 (01)
  • [3] Experimental and Numerical Investigations on Seismic Performance of CFST Frame with External Diaphragm Joint
    Rong, Bin
    Li, Hongtao
    Zhang, Ruoyu
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (11)
  • [4] Experimental basis for modeling the seismic behavior of masonry structures
    Tomazevic, M
    [J]. STRUCTURAL ENGINEERING AND MECHANICS, VOLS 1 AND 2, 1999, : 1221 - 1226
  • [5] Adjudging efficacy of geonet reinforcement on the seismic performance of brick masonry structures: an experimental study
    Susanta Banerjee
    Sanket Nayak
    Sreekanta Das
    [J]. Materials and Structures, 2021, 54
  • [6] Adjudging efficacy of geonet reinforcement on the seismic performance of brick masonry structures: an experimental study
    Banerjee, Susanta
    Nayak, Sanket
    Das, Sreekanta
    [J]. MATERIALS AND STRUCTURES, 2021, 54 (06)
  • [7] Experimental investigations on the influence of an external prestressing on the shear capacity of prestressed continuous beams
    Herbrand, M.
    Hegger, J.
    [J]. BAUINGENIEUR, 2013, 88 : 509 - 517
  • [8] Dynamic investigations on medieval masonry towers: Seismic resistance and strengthening techniques
    Abruzzese, D.
    Miccoli, L.
    Vari, A.
    Ferraioli, M.
    Mandara, A.
    Froncillo, S.
    [J]. PROTECTION OF HISTORICAL BUILDINGS - PROHITECH 09, VOL 1 AND 2, 2009, : 1207 - +
  • [9] Effects of the vertical seismic component on seismic performance of an unreinforced masonry structures
    Francesco Di Michele
    Cristina Cantagallo
    Enrico Spacone
    [J]. Bulletin of Earthquake Engineering, 2020, 18 : 1635 - 1656
  • [10] Seismic Performance of CFRP Strengthened Unreinforced Masonry Structures
    Yuan, Shengli
    [J]. ADVANCED ENGINEERING MATERIALS, PTS 1-3, 2011, 194-196 : 1904 - 1907