Defining and Assessing the Uncertainty Contributions in the Line-Injection Measurements of Transfer Impedance

被引:0
|
作者
Carobbi, Carlo [1 ]
Cati, Marco [2 ]
Panconi, Carlo [1 ]
机构
[1] Univ Florence, Via S Marta 3, I-50139 Florence, Italy
[2] Esaote SpA, I-50127 Florence, Italy
关键词
Transfer impedance; line-injection method; triaxial method; measurement uncertainty;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The shielding effectiveness of the coaxial transmission lines is currently quantified in terms of transfer impedance, a lumped-clement concept. Its measurement is based on two methods, the more recent of which, the line injection method, is intended to extend the technique to higher frequencies. In doing so, wave propagation effects are introduced which produce potential distortion of the quantity we intend to observe. Also, the test arrangement is imperfectly grounded, thus unpredictable common-mode coupling may be present.. This paper describes the approximations of the basic equations involved and the uncertainties related to the experimental equipment. A configuration of the injection fine intended to minimize common-mode effects, and improve the predictability and repeatability is adopted. An experimental verification based on the comparsion with the traditional and more closely defined method of the triaxial coupler is offered.
引用
收藏
页码:513 / +
页数:2
相关论文
共 5 条
  • [1] Measurements of transfer impedance with the line injection method on cables and connectors
    Bluhm, M
    Peroglio, E
    Pierucci, G
    Squizzato, V
    Zich, RE
    [J]. 2000 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1 AND 2, SYMPOSIUM RECORD, 2000, : 599 - 604
  • [2] Method for Determining the Width of Injection Line for Line Injection Method of Cable Transfer Impedance
    Chen, Lei
    Zhou, Xiang
    Gu, Yixing
    [J]. 2020 IEEE MTT-S INTERNATIONAL CONFERENCE ON NUMERICAL ELECTROMAGNETIC AND MULTIPHYSICS MODELING AND OPTIMIZATION (NEMO 2020), 2020,
  • [3] Transfer Impedance Measurements and Simulations on perforated Fully-Rigid Coaxial Cables with the Line Injection and the Triaxial Method
    Kreisch, Karsten
    Kubitzek, Stephan
    Hofmeister, Christian
    Baerenfaenger, Joerg
    Schugt, Michael
    [J]. 2014 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2014, : 850 - 855
  • [4] Experimental and theoretical comparison of the line injection and cylindrical test fixture methods for measuring surface transfer impedance of cables
    Hoeft, LO
    Salas, TM
    Prather, WD
    [J]. 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - SYMPOSIUM RECORD, VOLS 1 AND 2, 1998, : 532 - 536
  • [5] Interturn short diagnosis in small transformers through impulse injection: on-line on-load self-impedance transfer function approach
    Rajamani, Rajesh
    Rajappa, Muthaiah
    Arunachalam, Kamalaselvan
    Madanmohan, Balasubramanian
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2017, 11 (08) : 961 - 966