Diffusive gradients in thin-films (DGT) for in situ sampling of selected endocrine disrupting chemicals (EDCs) in waters

被引:91
|
作者
Chen, Wei [1 ,4 ]
Pan, Suhong [2 ,3 ]
Cheng, Hao [1 ]
Sweetman, Andrew J. [1 ]
Zhang, Hao [1 ]
Jones, Kevin C. [1 ]
机构
[1] Univ Lancaster, Lancaster Environm Ctr, Lancaster LA1 4YQ, England
[2] Chinese Acad Sci, Guangzhou Inst Geochem, Guangzhou 510640, Guangdong, Peoples R China
[3] Guangdong Inst Ecoenvironm & Soil Sci, Guangdong Key Lab Agr Environm Pollut Integrated, Guangzhou 510650, Guangdong, Peoples R China
[4] Hong Kong Baptist Univ, Dept Chem, State Key Lab Environm & Biol Anal, Kowloon Tong, Hong Kong, Peoples R China
关键词
Passive sampling; Diffusive gradients in thin-films (DGT); Wastewater; Water framework directive; Water quality; Monitoring; PERSONAL-CARE PRODUCTS; WASTE-WATER; INTEGRATIVE SAMPLERS; AQUATIC ENVIRONMENT; ORGANIC CONTAMINANTS; SURFACE-WATER; ILLICIT DRUGS; CALIBRATION; PHARMACEUTICALS; POLLUTANTS;
D O I
10.1016/j.watres.2018.03.029
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A passive water sampler based on the diffusive gradients in thin-films (DGT) technique was developed and tested for 3 groups of endocrine disrupting chemicals (EDCs, including oestrogens, alkyl-phenols and bisphenols). Three different resins (hydrophilic-lipophilic-balanced (HLB), XAD18 and Strata-XL-A (SXLA)) were investigated for their suitability as the binding phase for DGT devices. Laboratory tests across a range of pH (3.5-9.5), ionic strength (0.001-0.5 M) and dissolved organic matter concentration (0-20 mg L-1) showed HLB and XAD18-DGT devices were more stable compared to SXLA-DGT. HLB-DGT and XAD18-DGT accumulated test chemicals with time consistent with theoretical predictions, while SXLA-DGT accumulated reduced amounts of chemical. DGT performance was also compared in field deployments up to 28 days, alongside conventional active sampling at a wastewater treatment plant Uptake was linear to the samplers over 18 days, and then began to plateau/decline, indicating the maximum deployment time in those conditions. Concentrations provided by the DGT samplers compared well with those provided by auto-samplers. DGT integrated concentrations over the deployment period in a way that grab-sampling cannot. The advantages of the DGT sampler over active sampling include: low cost, ease of simultaneous multi-site deployment, in situ analyte pre-concentration and reduction of matrix interferences compared with conventional methods. Compared to other passive sampler designs, DGT uptake is independent of flow rate and therefore allows direct derivation of field concentrations from measured compound diffusion coefficients. This passive DGT sampler therefore constitutes a viable and attractive alternative to conventional grab and active water sampling for routine monitoring of selected EDCs. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:211 / 219
页数:9
相关论文
共 50 条
  • [1] Investigation and application of diffusive gradients in thin-films technique for measuring endocrine disrupting chemicals in seawaters
    Xie, Huaijun
    Chen, Qining
    Chen, Jingwen
    Chen, Chang-Er L.
    Du, Juan
    [J]. CHEMOSPHERE, 2018, 200 : 351 - 357
  • [2] Tetrafluoroterephthalonitrile-crosslinked β-cyclodextrin polymer as a binding agent of diffusive gradients in thin-films for sampling endocrine disrupting chemicals in water
    Li, Huan
    Qi, Shihua
    Li, Xiaoshui
    Qian, Zhe
    Chen, Wei
    Qin, Shibin
    [J]. CHEMOSPHERE, 2021, 280
  • [3] Development and application of diffusive gradients in thin-films for in situ sampling of the bitterest chemical-denatonium benzoate in waters
    Liu, Sisi
    Chen, Shibao
    Li, Xiaohao
    Yue, Yubo
    Li, Jinling
    Williams, Paul N.
    Wang, Zhanyun
    Li, Cailin
    Yang, Yuanyuan
    Ying, Guang-Guo
    Chen, Chang-Er
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2021, 418
  • [4] Development and validation of diffusive gradients in thin-films for in situ monitoring of ionic liquids in waters
    Liu, Si-Si
    Chen, Shi-Bao
    Yue, Yu-Bo
    Li, Xiao-Hao
    Zhang, Chi
    Ying, Guang-Guo
    Chen, Chang-Er
    [J]. Analytical Methods, 2024, 16 (46) : 7955 - 7964
  • [5] Concurrent sampling of transitional and coastal waters by Diffusive Gradient in Thin-films (DGT) and spot sampling for trace metals analysis
    Bersuder, Philippe
    Amouroux, Isabelle
    Jesus Belzunce-Segarra, Maria
    Bolam, Thi
    Caetano, Miguel
    Carvalho, Ines
    Santos, Margarida Correia dos
    Fones, Gary R.
    Gonzalez, Jean-Louis
    Guesdon, Stephane
    Larreta, Joana
    Marras, Barbara
    McHugh, Brendan
    Menet-Nedelec, Florence
    Menchaca, Iratxe
    Gabet, Vanessa Millan
    Montero, Natalia
    Nolan, Martin
    Regan, Fiona
    Robinson, Craig D.
    Rosa, Nuno
    Sanz, Marta Rodrigo
    Rodriguez, Jose German
    Schintu, Marco
    White, Blanaid
    Zhang, Hao
    [J]. METHODSX, 2021, 8
  • [6] Diffusive gradients in thin films (DGT) probe for effectively sampling of per- and polyfluoroalkyl substances in waters and sediments
    Yang, Yuanyuan
    Liu, Sisi
    Wang, Runmei
    Li, Cailin
    Tang, Jianhui
    Chen, Tao
    Ying, Guang-Guo
    Chen, Chang-Er
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCES, 2022, 121 : 90 - 97
  • [7] Diffusive gradients in thin films(DGT) probe for effectively sampling of per-and polyfluoroalkyl substances in waters and sediments
    Yuanyuan Yang
    Sisi Liu
    Runmei Wang
    Cailin Li
    Jianhui Tang
    Tao Chen
    Guang-Guo Ying
    Chang-Er Chen
    [J]. Journal of Environmental Sciences, 2022, 121 (11) : 90 - 97
  • [8] In situ Measurement of Trace Metals in Estuarine Waters of Patos Lagoon using Diffusive Gradients in Thin Films (DGT)
    Wallner-Kersanach, Monica
    de Andrade, Carlos Francisco F.
    Zhang, Hao
    Milania, Marcio R.
    Niencheski, Luis Felipe H.
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (02) : 333 - 340
  • [9] Chromium (VI) in phosphorus fertilizers determined with the diffusive gradients in thin-films (DGT) technique
    Vogel, Christian
    Hoffmann, Marie C.
    Krueger, Oliver
    Murzin, Vadim
    Caliebe, Wolfgang
    Adam, Christian
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (19) : 24320 - 24328
  • [10] Chromium (VI) in phosphorus fertilizers determined with the diffusive gradients in thin-films (DGT) technique
    Christian Vogel
    Marie C. Hoffmann
    Oliver Krüger
    Vadim Murzin
    Wolfgang Caliebe
    Christian Adam
    [J]. Environmental Science and Pollution Research, 2020, 27 : 24320 - 24328