Determination of Plant Hormones in Fertilizers by High-Performance Liquid Chromatography with Photodiode Array Detection: Method Development and Single-Laboratory Validation

被引:0
|
作者
Gambino, Grazia Laura [1 ]
Pagano, Pietro [1 ]
Scordino, Monica [1 ]
Sabatino, Leonardo [1 ]
Scollo, Emanuele [1 ]
Traulo, Pasqualino [1 ]
Gagliano, Giacomo [1 ]
机构
[1] Minist Polit Agr Alimentari & Forestali, Ispettorato Cent Controllo Qual Prodotti Agroalim, Lab Catania, I-95123 Catania, Italy
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and reliable high-performance liquid chromatographic method that uses photodiode array detection was developed for the simultaneous determination of 12 native and synthetic plant hormones, i.e., plant growth regulators (PGRs), in fertilizers, such as 1-naphthol, 2,4-dichlorophenoxyacetic acid, 4-(2,4-dichlorophenoxy)butyric acid, 4-chlorophenoxyacetic acid, indole-3-acetic acid, 4-(3-indolyl)butyric acid, dichlorprop, (4-chloro-2-methylphenoxy)acetic acid, alpha-naphthaleneacetic acid, 1-naphthalene-acetamide, beta-naphthoxyacetic acid, and thidiazuron. The method was experimentally validated for routine regulatory application, and the following analytical parameters were assessed for all PGRs studied: linearity; specificity; precision (relative standard deviation) and accuracy, both measured at 3 concentration levels (0.1, 0.05, and 0.01%, w/w); ruggedness; limit of detection; and limit of quantification. Results were satisfactory for all method validation parameters tested and for all PGRs studied, demonstrating the suitability of the method for the determination of PGRs in fertilizers. The uncertainty of measurement was also estimated at 3 concentration levels for all PGRs by using the approach of the International Organization for Standardization, described in its Guide to the Expression of Uncertainty in Measurement. The method was applied to 20 samples of liquid fertilizer with declared biostimulant properties.
引用
收藏
页码:1245 / 1256
页数:12
相关论文
共 50 条
  • [1] Determination of plant hormones in fertilizers by high-performance liquid chromatography with photodiode array detection: Method development and single-laboratory validation
    Gambino, Grazia Laura
    Pagano, Pietro
    Scordino, Monica
    Sabatino, Leonardo
    Scollo, Emanuele
    Traulo, Pasqualino
    Gagliano, Giacomo
    [J]. Journal of AOAC International, 1600, 91 (06): : 1245 - 1256
  • [2] Optimization and single-laboratory validation of a method for the determination of flavonolignans in milk thistle seeds by high-performance liquid chromatography with ultraviolet detection
    Elizabeth Mudge
    Lori Paley
    Andreas Schieber
    Paula N. Brown
    [J]. Analytical and Bioanalytical Chemistry, 2015, 407 : 7657 - 7666
  • [3] Optimization and single-laboratory validation of a method for the determination of flavonolignans in milk thistle seeds by high-performance liquid chromatography with ultraviolet detection
    Mudge, Elizabeth
    Paley, Lori
    Schieber, Andreas
    Brown, Paula N.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (25) : 7657 - 7666
  • [4] Optimization and single-laboratory validation study of a high-performance liquid chromatography (HPLC) method for the determination of phenolic Echinacea constituents
    Paula N. Brown
    Michael Chan
    Joseph M. Betz
    [J]. Analytical and Bioanalytical Chemistry, 2010, 397 : 1883 - 1892
  • [5] Optimization and single-laboratory validation study of a high-performance liquid chromatography (HPLC) method for the determination of phenolic Echinacea constituents
    Brown, Paula N.
    Chan, Michael
    Betz, Joseph M.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (05) : 1883 - 1892
  • [6] Determination of acaricides in honey by high-performance liquid chromatography with photodiode array detection
    Martel, AC
    Zeggane, S
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 954 (1-2) : 173 - 180
  • [7] Determination of Anthocyanins in Cranberry Fruit and Cranberry Fruit Products by High-Performance Liquid Chromatography with Ultraviolet Detection: Single-Laboratory Validation
    Brown, Paula N.
    Shipley, Paul R.
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2011, 94 (02) : 459 - 466
  • [8] Method for the Determination of Catechin and Epicatechin Enantiomers in Cocoa-Based Ingredients and Products by High-Performance Liquid Chromatography: Single-Laboratory Validation
    Machonis, Philip R.
    Jones, Matthew A.
    Schaneberg, Brian T.
    Kwik-Uribe, Catherine L.
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (02) : 500 - 507
  • [9] DETERMINATION OF GANGLIOSIDES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTODIODE-ARRAY DETECTION
    PREVITI, M
    DOTTA, F
    PONTIERI, GM
    DIMARIO, U
    LENTI, L
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 605 (02): : 221 - 225
  • [10] Single-laboratory validation determination of ubidecarenone (coenzyme q10, ubiquinol-10) in raw materials and dietary supplements by high-performance liquid chromatography with ultraviolet detection: Single-laboratory validation
    Orozco, Debra
    Skamarack, Jules
    Reins, Kelly
    Titlow, Barry
    Lunetta, Steve
    Li, Fang
    Roman, Mark
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2007, 90 (05) : 1227 - 1236