FULL-COVERAGE FILM COOLING: HEAT TRANSFER COEFFICIENTS AND FILM EFFECTIVENESS FOR A SPARSE HOLE ARRAY AT DIFFERENT BLOWING RATIOS AND CONTRACTION RATIOS

被引:0
|
作者
Ligrani, Phil [1 ]
Goodrog, Matt [1 ]
Fox, Michael D. [2 ]
Moon, Hee-Koo [2 ]
机构
[1] Univ Oxford, Dept Engn Sci, Oxford, England
[2] Solar Turbines Inc, San Diego, CA USA
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present experimental investigation considers a full coverage film cooling arrangement with differrent streamwise static pressure gradients. The film cooling holes in adjacent streamwise rows are staggered with respect to each other, with sharp edges, and streamwise inclination angles of 20 degrees with respect to the liner surface. Data are provided for turbulent film cooling, contraction ratios of 1 and 4, blowing ratios (at the test section entrance) of 2.0, 5.0, and 10.0, coolant Reynolds numbers of 12,000, freestream temperatures from 75 degrees C to 115 degrees C, a film hole diameter of 7 mm, and density ratios from 1.15 to 1.25. Non-dimensional streamwise and spanwise film cooling hole spacings, X/D and Y/D, are 18, and 5, respectively. Data illustrating the effects of contraction ratio, blowing ratio, and streamwise location on local, line-averaged and spatially-averaged adiabatic film effectiveness data, and on local, line-averaged and spatially-averaged heat transfer coefficient data are presented. Varying blowing ratio values are utilized along the length of the contraction passage, which contains the cooling hole arrangement, when contraction ratio is 4. Dependence on blowing ratio indicates important influences of coolant concentration and distribution. For example, line-averaged and spatially-averaged adiabatic effectiveness data show vastly different changes with blowing ratio BR for the configurations with contraction ratios of 1 and 4. These changes from acceleration are thus mostly due to different blowing ratio distributions along the test section. In particular, much larger effectiveness alterations are present as BR changes from 2.0 to 10.0, when significant acceleration is present and Cr=4 (in comparison with the Cr=1 data). When BR=10.0, much smaller changes due to different contract ratios are present. This is because coolant distributions along the test surfaces are so abundant that magnitudes of streamwise acceleration (and different streamwise variations of blowing ratio) have little effect on near-wall film concentration distributions, or on variations of film cooling effectiveness.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Full-Coverage Film Cooling: Heat Transfer Coefficients and Film Effectiveness for a Sparse Hole Array at Different Blowing Ratios and Contraction Ratios
    Ligrani, Phil
    Goodro, Matt
    Fox, Michael D.
    Moon, Hee-Koo
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2015, 137 (03):
  • [2] FULL-COVERAGE FILM COOLING: FILM EFFECTIVENESS AND HEAT TRANSFER COEFFICIENTS FOR DENSE HOLE ARRAYS AT DIFFERENT HOLE ANGLES, CONTRACTION RATIOS, AND BLOWING RATIOS
    Goodro, Matt
    Ligrani, Phil
    Fox, Mike
    Moon, Hee-Koo
    PROCEEDINGS OF THE ASME TURBO EXPO 2012, VOL 4, PTS A AND B, 2012, : 1707 - +
  • [3] Full-coverage film cooling: Film effectiveness and heat transfer coefficients for dense hole arrays at different hole angles, contraction ratios, and blowing ratios
    Department of Engineering Science, University of Oxford, Oxford, United Kingdom
    不详
    不详
    Proc. ASME Turbo Expo, PARTS A AND B (1707-1723):
  • [4] Full-Coverage Film Cooling: Film Effectiveness and Heat Transfer Coefficients for Dense Hole Arrays at Different Hole Angles, Contraction Ratios, and Blowing Ratios
    Ligrani, Phil
    Goodro, Matt
    Fox, Mike
    Moon, Hee-Koo
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2013, 135 (03):
  • [5] Full-Coverage Film Cooling: Film Effectiveness and Heat Transfer Coefficients for Dense and Sparse Hole Arrays at Different Blowing Ratios
    Ligrani, Phil
    Goodro, Matt
    Fox, Mike
    Moon, Hee-Koo
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2012, 134 (06):
  • [6] FULL-COVERAGE FILM COOLING: FILM EFFECTIVENESS AND HEAT TRANSFER COEFFICIENTS FOR DENSE AND SPARSE HOLE ARRAYS AT DIFFERENT BLOWING RATIOS
    Goodro, Matt
    Ligrani, Phil
    Fox, Mike
    Moon, Hee-Koo
    PROCEEDINGS OF THE ASME TURBO EXPO 2011, VOL 5, PTS A AND B, 2012, : 195 - 209
  • [7] EFFECTIVENESS AND HEAT-TRANSFER WITH FULL-COVERAGE FILM COOLING
    METZGER, DE
    TAKEUCHI, DI
    KUENSTLE.PA
    JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1973, 95 (03): : 180 - 184
  • [8] CONJUGATE HEAT TRANSFER ON FULL-COVERAGE FILM COOLING WITH ARRAY IMPINGEMENT JETS
    Jung, Eui Yeop
    Chung, Heeyoon
    Choi, Seok Min
    Wool, Ta-kwan
    Choi, Hyung Hee
    ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2015, VOL 5A, 2015,
  • [9] EFFECTIVENESS AND HEAT-TRANSFER WITH FULL-COVERAGE FILM - DISCUSSION
    BURGGRAF, F
    JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1974, 96 (03): : 318 - 319
  • [10] EFFECT OF ARRAY JET ON COOLING EFFECTIVENESS ON FULL-COVERAGE FILM COOLED SURFACE
    Lee, Dong Hyun
    Oh, Sang Hyun
    Jung, Eui Yeop
    Kim, Kyung Min
    Cho, Hyung Hee
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE 2009, VOL 2, 2009, : 565 - 572