Fast 3D iterative image reconstruction for SPECT with rotating slat collimators

被引:7
|
作者
Van Holen, Roel [1 ]
Vandenberghe, Stefaan [1 ]
Staelens, Steven [1 ]
De Beenhouwer, Jan [1 ]
Lemahieu, Ignace [1 ]
机构
[1] Univ Ghent, ELIS Dept, MEDISIP, IBBT,IBiTech, B-9000 Ghent, Belgium
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 03期
关键词
D O I
10.1088/0031-9155/54/3/016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As an alternative to the use of traditional parallel hole collimators, SPECT imaging can be performed using rotating slat collimators. While maintaining the spatial resolution, a gain in image quality could be expected from the higher photon collection efficiency of this type of collimator. However, the use of iterative methods to do fully three-dimensional (3D) reconstruction is computationally much more expensive and furthermore involves slow convergence compared to a classical SPECT reconstruction. It has been proposed to do 3D reconstruction by splitting the system matrix into two separate matrices, forcing the reconstruction to first estimate the sinograms from the rotating slat SPECT data before estimating the image. While alleviating the computational load by one order of magnitude, this split matrix approach would result in fast computation of the projections in an iterative algorithm, but does not solve the problem of slow convergence. There is thus a need for an algorithm which speeds up convergence while maintaining image quality for rotating slat collimated SPECT cameras. Therefore, we developed a reconstruction algorithm based on the split matrix approach which allows both a fast calculation of the forward and backward projection and a fast convergence. In this work, an algorithm of the maximum likelihood expectation maximization (MLEM) type, obtained from a split system matrix MLEM reconstruction, is proposed as a reconstruction method for rotating slat collimated SPECT data. Here, we compare this new algorithm to the conventional split system matrix MLEM method and to a gold standard fully 3D MLEM reconstruction algorithm on the basis of computational load, convergence and contrast-to-noise. Furthermore, ordered subsets expectation maximization (OSEM) implementations of these three algorithms are compared. Calculation of computational load and convergence for the different algorithms shows a speedup for the new method of 38 and 426 compared to the split matrix MLEM approach and the fully 3D MLEM respectively and a speedup of 16 and 21 compared to the split matrix OSEM and the fully 3D OSEM respectively. A contrast-to-noise study based on simulated data shows that our new approach has comparable accuracy as the fully 3D reconstruction method. The algorithm developed in this study allows iterative image reconstruction of rotating slat collimated SPECT data with equal image quality in a comparable amount of computation time as a classical SPECT reconstruction.
引用
收藏
页码:715 / 729
页数:15
相关论文
共 50 条
  • [1] Sensitivity of SPECT with rotating slat collimators
    Vandenberghe, S
    Staelens, S
    Koole, M
    Lemahieu, I
    Van de Walle, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2914 - 2918
  • [2] Fast iterative image reconstruction of 3D PET data
    Kinahan, PE
    Michel, C
    Defrise, M
    Townsend, DW
    Sibomana, M
    Lonneux, M
    Newport, DF
    Luketich, JD
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1918 - 1922
  • [3] Image reconstruction algorithm for a SPECT system with a convergent rotating slat collimator
    Zeng, GL
    Gagnon, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) : 142 - 148
  • [4] Approximate 3D iterative reconstruction for SPECT
    Gilland, DR
    Jaszczak, RJ
    Riauka, TA
    Coleman, RE
    MEDICAL PHYSICS, 1997, 24 (09) : 1421 - 1429
  • [5] Derivation and implementation of an analytical 3-D image reconstruction algorithm for SPECT with rotating slant hole collimators.
    Wessell, DE
    Tsui, BMW
    Frey, EC
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 179P - 180P
  • [6] ACCELERATED FULLY 3D ITERATIVE RECONSTRUCTION IN SPECT
    Backfrieder, Werner
    Zwettler, Gerald A.
    23RD EUROPEAN MODELING & SIMULATION SYMPOSIUM, EMSS 2011, 2011, : 100 - 104
  • [7] Comparison of 3D SPECT Imaging with a Rotating Slat Collimator and a Parallel Hole Collimator
    Van Holen, Roel
    Vandenberghe, Stefaan
    Staelens, Steven
    Lemahieu, Ignace
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3865 - 3870
  • [8] A detailed investigation of non-iterative methods for 3D SPECT image reconstruction
    Pan, XC
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1747 - 1751
  • [9] 3D RBI-EM reconstruction with spherically-symmetric basis function for SPECT rotating slat collimator
    Wang, WL
    Hawkins, W
    Gagnon, D
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11): : 2273 - 2292
  • [10] Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction
    Kadrmas, DJ
    Frey, EC
    Karimi, SS
    Tsui, BMW
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 857 - 873