Long-Term Storage at-80°C: Effect on Rate of Recovery of Mycobacterium tuberculosis From Direct Acid-Fast Bacilli Smear-Positive Sputum Samples

被引:4
|
作者
Shinu, Pottathil [1 ]
Singh, Varsha AshokKumar [1 ]
Nair, Anroop [2 ]
Farooq, Rumana [1 ]
Ishaq, Sheikh [3 ]
机构
[1] MM Univ, MMIMSR, Dept Microbiol, Ambala 133207, Haryana, India
[2] King Faisal Univ, Coll Clin Pharm, Dept Pharmaceut Sci, Al Hasa, Saudi Arabia
[3] MM Univ, MMIMSR, Dept Biochem, Ambala, Haryana, India
关键词
Mycobacterium tuberculosis; long-term storage; MGIT (TM) system; LJ media; MB; 7H11; agar; GROWTH INDICATOR TUBE; CETYLPYRIDINIUM CHLORIDE; CROSS-CONTAMINATION; LOWENSTEIN-JENSEN; SODIUM-CHLORIDE; PULMONARY; DECONTAMINATION; SPECIMENS; MB;
D O I
10.1002/jcla.21904
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The aim of this study was to evaluate the difference in the rate of recovery of Mycobacterium tuberculosis (MTB) from routinely cultured sputum and long-term stored sputum specimens (at -80 degrees C) using Lowenstein-Jensen (LJ) media, Mycobacterium Growth Indicator Tube (BBL MGIT (TM)), and Middlebrook 7H11 (MB 7H11) agar. Methods: Direct acid-fast bacilli smear-positive sputum specimens (both before and after storage [n = 136]) were studied (after culturing on LJ media, BBL MGIT (TM), and MB 7H11 agar) and the performances were compared. Results: For the detection of MTB, BBL MGIT (TM) and MB 7H11 agar (before storage) demonstrated a sensitivity, specificity, positive predictive value (PPV) of 98.28%, 30.77%, 92.68%, 66.67%, and negative predictive value (NPV) of 97.41%, 30.77%, 92.62%, 57.14%, respectively, when compared to LJ media (before storage). Similarly, BBL MGIT (TM) and MB 7H11 agar (after storage) demonstrated a sensitivity, specificity, PPV, and NPV of 95.5%, 38.89%, 90.6%, 58.33%, and 95.5%, 66.67 %, 94.64%, 70.59%, respectively, when compared to LJ media (after storage) for the detection of MTB. Conclusion: None of the culture techniques independently (both before and after storage) detected growth ofMTB from all the sputum specimens studied. However, BBL MGIT (TM) system and LJ media combination (both before and after storage) effectively detected the growth of MTB from sputum specimens when compared to other culture technique combinations. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:567 / 576
页数:10
相关论文
共 11 条
  • [1] Rate of Recovery of Mycobacterium tuberculosis from Frozen Acid-Fast-Bacillus Smear-Positive Sputum Samples Subjected to Long-Term Storage in Northwest Ethiopia
    Tessema, Belay
    Beer, Joerg
    Emmrich, Frank
    Sack, Ulrich
    Rodloff, Arne C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (07) : 2557 - 2561
  • [2] Validation of a model for predicting smear-positive active pulmonary tuberculosis in patients with initial acid-fast bacilli smear-negative sputum
    Yeh, Jun-Jun
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 243 - 256
  • [3] Validation of a model for predicting smear-positive active pulmonary tuberculosis in patients with initial acid-fast bacilli smear-negative sputum
    Jun -Jun Yeh
    European Radiology, 2018, 28 : 243 - 256
  • [4] CONSECUTIVE SPUTUM SPECIMENS FOR ACID-FAST BACILLI SMEAR IN SMEAR-POSITIVE, NON-HIV PULMONARY TUBERCULOSIS PATIENTS: DIAGNOSTIC YIELD AND PREDICTIVE FACTORS
    Loh, E-N
    Loh, L-C
    RESPIROLOGY, 2011, 16 : 81 - 81
  • [5] Recovery rate of NTM from AFB smear-positive sputum specimens during the pseudooutbreak of mycobacterium species at a long-term care facility
    Lee, Y. -W
    Jun, K. A.
    Shin, S. Y.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2010, 14 : E264 - E264
  • [6] EVALUATION OF THE BACTEC RADIOMETRIC METHOD FOR RECOVERY OF MYCOBACTERIA AND DRUG SUSCEPTIBILITY TESTING OF MYCOBACTERIUM-TUBERCULOSIS FROM ACID-FAST SMEAR-POSITIVE SPECIMENS
    ROBERTS, GD
    GOODMAN, NL
    HEIFETS, L
    LARSH, HW
    LINDNER, TH
    MCCLATCHY, JK
    MCGINNIS, MR
    SIDDIQI, SH
    WRIGHT, P
    JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (03) : 689 - 696
  • [7] Effect of long-term storage at-80 °C on the various lipid parameters in stored plasma samples
    Devanapalli, B
    Bermingham, MA
    Mahajan, D
    CLINICA CHIMICA ACTA, 2002, 322 (1-2) : 179 - 181
  • [8] Direct detection and identification of Mycobacterium tuberculosis in smear-positive sputum samples by fluorescence in situ hybridization (FISH) using peptide nucleic acid (PNA) probes
    Stender, H
    Mollerup, TA
    Lund, K
    Petersen, KH
    Hongmanee, P
    Godtfredsen, SE
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 1999, 3 (09) : 830 - 837
  • [9] Rapid and specific detection of Mycobacterium tuberculosis from acid-fast bacillus smear-positive respiratory specimens and BacT/ALERT MP culture bottles by using fluorogenic probes and real-time PCR
    Miller, N
    Cleary, T
    Kraus, G
    Young, AK
    Spruill, G
    Hnatyszyn, HJ
    JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (11) : 4143 - 4147
  • [10] Impact of uncontrolled freezing and long-term storage of peripheral blood stem cells at-80 °C on haematopoietic recovery after autologous transplantation. Report from two centres
    Detry, G.
    Calvet, L.
    Straetmans, N.
    Cabrespine, A.
    Ravoet, C.
    Bay, J. O.
    Petre, H.
    Paillard, C.
    Husson, B.
    Merlin, E.
    Boon-Falleur, L.
    Tournilhac, O.
    Delannoy, A.
    Halle, P.