Multi-axis passive and active stiffnesses of the glenohumeral joint

被引:9
|
作者
Makhsous, M
Lin, F
Zhang, LQ [1 ]
机构
[1] Northwestern Univ, Dept Phys Med & Rehabil, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Orthopaed Surg, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, Evanston, IL USA
[4] Rehabil Inst Chicago, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
glenohumeral joint; stiffness; stability; shoulder; in vitro;
D O I
10.1016/j.clinbiomech.2003.11.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To investigate passive and active glenohumeral stiffness in the anterior, posterior, superior, and inferior directions at different lateral positions of the humerus. Design. Glenohumeral stiffness along multiple axes was determined in fresh-frozen shoulder specimens under both passive (no simulated muscle contraction) and active (with simulated muscle contraction) conditions. Background. Glenohumeral laxity has been evaluated in various studies with focus on one of the multiple directions. However, glenohumeral stiffness characterizing the force-displacement relationship and stability has not been evaluated in all four directions under passive and active conditions. Methods. The humeral head was translated in the posterior, anterior, inferior and superior directions relative to the glenoid with different lateral positions, and multi-axis glenohumeral stiffness generated by passive and active structures were investigated. Results. Without muscle loading, glenohumeral stiffness in the superior direction (K-sup = 5.83 N/mm) was higher than that in the inferior (K-inf = 4.32), anterior (K-ant = 3.67), and posterior (K-post = 2.89) directions (P < 0.008), and K-inf was higher than K-post (P = 0.011). Stiffness in the different directions were correlated to each other (P < 0.001), and shifting the humerus laterally increased stiffness in all directions (P < 0.05) except for the superior direction. With moderate muscle loads, the glenohumeral joint became significantly stiffer in all four directions (P < 0.05) with less difference among different directions. Conclusions. Glenohumeral stiffnesses are different in the different directions but are correlated to each other and contribute jointly to glenohumeral stability. Muscle contractions can increase glenohumeral stiffness significantly.
引用
收藏
页码:107 / 115
页数:9
相关论文
共 50 条
  • [1] Active/passive vibration isolation with multi-axis transmission control: Analysis and experiment
    Ren, Mingke
    He, Peitao
    Xie, Xiling
    Zhang, Zhiyi
    [J]. JOURNAL OF VIBRATION AND CONTROL, 2023, 29 (21-22) : 5090 - 5106
  • [2] Optimization of multi-axis passive isolation systems
    Hyde, TT
    Davis, LP
    [J]. PASSIVE DAMPING AND ISOLATION - SMART STRUCTURES AND MATERIALS 1998, 1998, 3327 : 399 - 410
  • [3] A Lightweight, Multi-Axis Compliant Tensegrity Joint
    Lessard, Steven
    Bruce, Jonathan
    Jung, Erik
    Teodorescu, Mircea
    SunSpiral, Vytas
    Agogino, Adrian
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2016, : 630 - 635
  • [4] Assessment of the glenohumeral joint's active and passive axial rotational range
    Humphries, Alexander
    Cirovic, Srdjan
    Bull, Anthony M. J.
    Hearnden, Anthony
    Shaheen, Aliah F.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (12) : 1974 - 1981
  • [5] Multi-axis machining
    Anon
    [J]. Modern Machine Shop, 2002, 74 (08)
  • [6] Multi-axis marvels
    Allcock, Andrew
    [J]. Machinery, 2013, 171 (4208): : 25 - 26
  • [7] Multi-axis Active Vibration Suppression for Wafer Transfer Systems
    Qiu, Jiajie
    Kim, Hongjin
    Xia, Fangzhou
    Youcef-Toumi, Kamal
    [J]. 2023 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS, AIM, 2023, : 1108 - 1114
  • [8] Multi-Axis Laser
    不详
    [J]. BAUINGENIEUR, 2013, 88 : A27 - A27
  • [9] Multi-Axis Opportunities
    Sinkora, Ed
    [J]. MANUFACTURING ENGINEERING, 2023, 170 (01): : 60 - 63
  • [10] Development of a ten-station, multi-axis hip joint simulator
    Goldsmith, AAJ
    Dowson, D
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H4) : 311 - 316