Surface diaphragmatic electromyogram changes after laparotomy

被引:16
|
作者
Berdah, SV
Picaud, R
Jammes, Y
机构
[1] Hop Nord Marseille, Dept Digest Surg, Serv Chirurgie Digest, F-13915 Marseille 20, France
[2] Fac Med Marseille, Inst Jean Roche, Lab Physiopathol Resp EA2201, F-13385 Marseille, France
关键词
abdominal surgery; diaphragm; electromyogram (EMG); man; median frequency; root mean square (RMS);
D O I
10.1046/j.1365-2281.2002.00406.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The aim of this human study was to objective diaphragmatic electromyogram (EMG) changes after supraombilical laparotomy. The surface diaphragmatic EMG was recorded in patients (before and after laparotomy), and in healthy volunteers, during standardized inspiratory efforts sustained at -30 cmH(2)O (Muller manoeuvres). The quantitative EMG analysis showed significant postoperative modifications: the root mean square (RMS) increased and the median frequency (MF) decreased. These modifications are compatible with an altered diaphragmatic excitability and/or a reduced central drive to the diaphragm.
引用
收藏
页码:157 / 160
页数:4
相关论文
共 50 条
  • [1] CHANGES IN HUMAN DIAPHRAGMATIC ELECTROMYOGRAM WITH POSITIVE PRESSURE BREATHING
    MCKENZIE, DK
    GANDEVIA, SC
    NEUROSCIENCE LETTERS, 1986, 70 (01) : 86 - 90
  • [2] ELECTROMYOGRAM PATTERN OF DIAPHRAGMATIC FATIGUE
    GROSS, D
    GRASSINO, A
    ROSS, WRD
    MACKLEM, PT
    JOURNAL OF APPLIED PHYSIOLOGY, 1979, 46 (01) : 1 - 7
  • [3] Utility of Diaphragmatic Ultrasound and Diaphragmatic Electromyogram in Amyotrophic Lateral Sclerosis
    Sarasate Azkona, Mikel
    Izquierdo, Ana Cordoba
    Soro, Enric Prats
    Albinana, Edelweis Anton
    Gomez, Lluis Mateu
    Duarte, Luciana Baglivo
    Puchades, Alejandro Caravaca
    Rubio, Raul Dominguez
    Panades, Monica Povedano
    Munoz, Eva Farrero
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [4] INTRAMUSCULAR AND SURFACE ELECTROMYOGRAM CHANGES DURING MUSCLE FATIGUE
    MORITANI, T
    MURO, M
    NAGATA, A
    JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (04) : 1179 - 1185
  • [5] Modifications of Diaphragmatic Activity Induced by Midline Laparotomy and Changes in Abdominal Wall Compliance
    Gea, Joaquim
    Bautista Galdiz, Juan
    Comtois, Norman
    Zhu, Ercheng
    Salazkin, Igor
    Antonio Fiz, Jose
    Grassino, Alejandro
    ARCHIVOS DE BRONCONEUMOLOGIA, 2009, 45 (01): : 30 - 35
  • [6] A PROGRAM FOR DETECTION AND CHARACTERIZATION OF DIAPHRAGMATIC ELECTROMYOGRAM BURSTS
    GRASING, K
    COPLAN, S
    DWYER, G
    SZETO, H
    CLINICAL RESEARCH, 1989, 37 (02): : A476 - A476
  • [7] A comparative study to extract the diaphragmatic electromyogram signal
    Lu, Yaosheng
    Xian, Ying
    Chen, Jiongfeng
    Zheng, Zeguang
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 315 - +
  • [8] Changes in power of surface electromyogram during breath-holding
    Ostojic, Mirko
    Milosavljevic, Milan
    Kovacevic, Aleksandra
    Stokic, Miodrag
    Stefanovic, Dorde
    Mandic-Gajic, Gordana
    Jelicic, Ljiljana
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2020, 148 (7-8) : 440 - 446
  • [9] DIAPHRAGMATIC AND GENIOGLOSSAL ELECTROMYOGRAM RESPONSES TO ISOCAPNIC HYPOXIA IN HUMANS
    ONAL, E
    LOPATA, M
    OCONNOR, TD
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1981, 124 (03): : 215 - 217
  • [10] TECHNIQUE OF ONLINE ANALYSIS OF DIAPHRAGMATIC ELECTROMYOGRAM ACTIVITY IN THE NEWBORN
    CHAMBILLE, B
    VARDON, G
    MONRIGAL, JP
    DEHAN, M
    GAULTIER, C
    EUROPEAN RESPIRATORY JOURNAL, 1989, 2 (09) : 883 - 886