Reduced-Dose Low-Voltage Chest CT Angiography with Sinogram-affirmed Iterative Reconstruction versus Standard-Dose Filtered Back Projection

被引:86
|
作者
Pontana, Francois [1 ]
Pagniez, Julien [1 ]
Duhamel, Alain [2 ]
Flohr, Thomas [3 ]
Faivre, Jean-Baptiste [1 ]
Murphy, Colm [1 ]
Remy, Jacques [1 ]
Remy-Jardin, Martine [1 ]
机构
[1] Univ Lille Nord France, Hop Calmette EA 2694, Dept Thorac Imaging, F-59037 Lille, France
[2] Univ Lille Nord France, Hop Calmette EA 2694, Dept Med Stat, F-59037 Lille, France
[3] Siemens Healthcare, Computed Tomog Div, Forchheim, Germany
关键词
COMPUTED-TOMOGRAPHY ANGIOGRAPHY; IMAGE QUALITY; VASCULAR ENHANCEMENT; RADIATION-EXPOSURE; PULMONARY-ARTERIES; REDUCTION; ADULTS;
D O I
10.1148/radiol.12120414
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate image quality of low-voltage chest computed tomographic (CT) angiography with raw data-based iterative reconstruction (sonogram-affirmed iterative reconstruction) in comparison with image quality of standard-dose standard-voltage filtered back projection (FBP) CT. Materials and Methods: This prospective study was approved by the institutional review board, and the informed consent requirement was waived. Eighty consecutive patients who were referred for follow-up chest CT angiography underwent reduced-dose CT (hereafter, T2 examination) under technical conditions similar to those of the initial examination (hereafter, T1 examination), except the voltage selection was reduced by 20 kV with adaptation of the tube current to ensure a 50% reduction in CT dose index, and regular FBP was replaced by iterative reconstruction with sonogram-affirmed iterative reconstruction. The two techniques were compared by using paired tests (Student t test, Wilcoxon test, or McNemar test, according to the nature of variables). Results: When compared with standard-dose T1 studies, reduced-dose T2 images showed: (a) significantly less objective noise at the level of the trachea on mediastinal and lung parenchymal images (P < .001) and no significant difference in objective noise at the level of the aorta on mediastinal images (P = .507); (b) significantly higher signal-to-noise and contrast-to-noise (P < .001) ratios; (c) similar visual perception of noise on mediastinal (P = .132) and lung (P = .366) images, mainly rated as moderate; and (d) similar overall subjective image quality (P = .405). Conclusion: Raw data-based iterative reconstruction yielded equivalent subjective and improved objective image quality of low-voltage half-dose CT angiograms compared with standard-dose FBP CT images for an average dose-length product of less than 80 mGy . cm in this population. (C) RSNA, 2013
引用
收藏
页码:609 / 618
页数:10
相关论文
共 50 条
  • [1] Image quality and radiation dose of low dose coronary CT angiography in obese patients: Sinogram affirmed iterative reconstruction versus filtered back projection
    Wang, Rui
    Schoepf, U. Joseph
    Wu, Runze
    Reddy, Ryan P.
    Zhang, Chuanchen
    Yu, Wei
    Liu, Yi
    Zhang, Zhaoqi
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3141 - 3145
  • [2] Detection of Urothelial Carcinoma: Comparison of Reduced-Dose Iterative Reconstruction with Standard-Dose Filtered Back Projection
    Bahn, Young Eun
    Kim, See Hyung
    Kim, Mi Jeong
    Kim, Chan Sun
    Kim, Young Hwan
    Cho, Seung Hyun
    RADIOLOGY, 2016, 279 (02) : 471 - 480
  • [3] Benefits of sinogram-affirmed iterative reconstruction in 0.4 mSv ultra-low-dose CT of the upper abdomen following transarterial chemoembolisation: comparison to low-dose and standard-dose CT and filtered back projection technique
    Bodelle, B.
    Isler, S.
    Scholtz, J. -E.
    Frellesen, C.
    Luboldt, W.
    Vogl, T. J.
    Beeres, M.
    CLINICAL RADIOLOGY, 2016, 71 (01) : E11 - E15
  • [4] Low-Dose Chest Computed Tomography With Sinogram-Affirmed Iterative Reconstruction, Iterative Reconstruction in Image Space, and Filtered Back Projection: Studies on Image Quality
    Hwang, Hye Jeon
    Seo, Joon Beom
    Lee, Hyun Joo
    Lee, Sang Min
    Kim, Eun Young
    Oh, Sang Young
    Kim, Ji-Eun
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 610 - 617
  • [5] CT coronary angiography: Image quality with sinogram-affirmed iterative reconstruction compared with filtered back-projection
    Wang, R.
    Schoepf, U. J.
    Wu, R.
    Gibbs, K. P.
    Yu, W.
    Li, M.
    Zhang, Z.
    CLINICAL RADIOLOGY, 2013, 68 (03) : 272 - 278
  • [6] Half-dose abdominal CT with sinogram-affirmed iterative reconstruction technique in children — comparison with full-dose CT with filtered back projection
    Minwook Lee
    Myung-Joon Kim
    Kyung Hwa Han
    Mi-Jung Lee
    Pediatric Radiology, 2015, 45 : 188 - 193
  • [7] Half-dose abdominal CT with sinogram-affirmed iterative reconstruction technique in children - comparison with full-dose CT with filtered back projection
    Lee, Minwook
    Kim, Myung-Joon
    Han, Kyung Hwa
    Lee, Mi-Jung
    PEDIATRIC RADIOLOGY, 2015, 45 (02) : 188 - 193
  • [8] Sinogram-Affirmed Iterative Reconstruction of Low-Dose Chest CT: Effect on Image Quality and Radiation Dose
    Kalra, Mannudeep K.
    Woisetschlaeger, Mischa
    Dahlstroem, Nils
    Singh, Sarabjeet
    Digumarthy, Subbarao
    Do, Synho
    Pien, Homer
    Quick, Petter
    Schmidt, Bernhard
    Sedlmair, Martin
    Shepard, Jo-Anne O.
    Persson, Anders
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (02) : W235 - W244
  • [9] Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction
    Lee, So Won
    Kim, Yookyung
    Shim, Sung Shine
    Lee, Jeong Kyong
    Lee, Seok Jeong
    Ryu, Yon Ju
    Chang, Jung Hyun
    EUROPEAN RADIOLOGY, 2014, 24 (04) : 817 - 826
  • [10] Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction
    So Won Lee
    Yookyung Kim
    Sung Shine Shim
    Jeong Kyong Lee
    Seok Jeong Lee
    Yon Ju Ryu
    Jung Hyun Chang
    European Radiology, 2014, 24 : 817 - 826