A Two-Piece Sectional Interim Obturator. A Clinical Report

被引:2
|
作者
Popli, Sachet
Parkash, Hari [1 ]
Bhargava, Akshay [1 ]
Gupta, Sharad [1 ]
Bablani, Deepika [2 ]
Kar, Aswini Kumar [3 ]
机构
[1] ITS CDSR, Dept Prosthodont, Ghaziabad, India
[2] Jamia Millia Islamia, Fac Dent, New Delhi, India
[3] Kalinga Inst Dent Sci, Dept Prosthodont, Bhubaneswar, Orissa, India
关键词
Sectional obturator; enucleation; two-piece interim obturator; interim obturator; split obturator; split-interim obturator; DENTURE; MICROSTOMIA; PROSTHESES; PATIENT;
D O I
10.1111/j.1532-849X.2012.00849.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Prosthetic rehabilitation of acquired maxillary defects can be achieved satisfactorily if all facets of treatment planning and design considerations are taken into account before the rehabilitation process. Complications associated with maxillary defects limit treatment protocols to a great extent. The prosthodontist has to identify these problem areas and suitably devise feasible options and incorporate them in the design. In this report, an acquired maxillary defect with unfavorable undercuts in the defect was successfully treated by making a two-piece sectional obturator. The two pieces were connected by the use of double-die pin system. The methodology greatly reduced chairside time and number of visits, and effective obturation was satisfactorily achieved.
引用
收藏
页码:487 / 490
页数:4
相关论文
共 50 条
  • [1] Prosthetic Rehabilitation of a Maxillectomy with a Two-Piece Hollow Bulb Obturator. A Clinical Report
    Padmanabhan, T. V.
    Kumar, V. Anand
    Mohamed, K. Kasim
    Unnikrishnan, Nandini
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (05): : 397 - 401
  • [2] Replacement of an obturator section of an existing two-piece implant-retained edentulous obturator
    MacCarthy, D
    Murphy, N
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (06): : 652 - 655
  • [3] A Direct Investment Method of Closed Two-Piece Hollow Bulb Obturator
    Deogade, Suryakant C.
    Mantri, Sneha S.
    Naitam, Dinesh
    Dube, Gunjan
    Gupta, Pushkar
    Dewangan, Ashish
    [J]. CASE REPORTS IN DENTISTRY, 2013, 2013
  • [4] Oromaxillary Prosthetic Rehabilitation of a Maxillectomy Patient Using a Magnet Retained Two-Piece Hollow Bulb Definitive Obturator; A Clinical Report
    Usman, Jafar Abdulla Mohamed
    Ayappan, Anuroopa
    Ganapathy, Dhanraj
    Nasir, Nilofer Nisha
    [J]. CASE REPORTS IN DENTISTRY, 2013, 2013
  • [5] Rehabilitation of squamous cell carcinoma defect with two-piece hollow bulb obturator prosthesis - A case report
    Kuttae Viswanathan, Anitha
    Ganapathy, Dhanraj M.
    [J]. CLINICAL CASE REPORTS, 2021, 9 (06):
  • [6] Two-Piece Hollow Bulb Obturator for Postsurgical Partial Maxillectomy Defect in a Young Patient Revamping Lost Malar Prominence: A Clinical Report
    Vaidya, Sharad
    Parkash, Hari
    Gupta, Sharad
    Bhargava, Akshay
    Kapoor, Charu
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (01): : 71 - 76
  • [7] Two-piece shredder
    不详
    [J]. BIOCYCLE, 1997, 38 (11) : 88 - 88
  • [8] MODIFYING A SURGICAL OBTURATOR PROSTHESIS INTO AN INTERIM OBTURATOR PROSTHESIS - A CLINICAL REPORT
    WOLFAARDT, JF
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (06): : 619 - 621
  • [9] Two-Piece Nasal Septum Prosthesis for a Large Nasal Septum Perforation: A Clinical Report
    Purna, C. R. Sashi
    Annapurna, P. D.
    Ahmed, Syed Basheer
    Vurla, Samyuktha
    Nalla, Sandeep
    Abhishek, S. M.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (02): : 143 - 147
  • [10] Two-piece transformer cores
    不详
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1943, 14 (08): : 258 - 258