WIDE-ANGLE FUNDUS IMAGING THROUGH THE BOSTON KERATOPROSTHESIS

被引:10
|
作者
Sayegh, Rony R. [1 ]
Dohlman, Claes H. [1 ]
机构
[1] Harvard Univ, Massachusetts Eye & Ear Infirm, Dept Ophthalmol, Sch Med, Boston, MA 02114 USA
关键词
keratoprosthesis; optics; imaging; fundus; retina; PERMANENT KERATOPROSTHESIS; SILICONE OIL; MANAGEMENT; HYPOTONY; LESIONS; EYES;
D O I
10.1097/IAE.0b013e3182869ec2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To explore the feasibility and compare the outcomes of three wide-angle fundus cameras for imaging the peripheral retina through the Type 1 Boston keratoprosthesis. Methods: The noncontact Optos and the contact RetCam and Panoret wide-angle imaging systems were used to image the retina of eyes implanted with a keratoprosthesis. The failure-to-image rate, ease of acquisition, and quality of the images were noted, and the field of view was compared. Limitations and complications were recorded. Optos was then performed on patients referred for ultrasound B-scan evaluation, and the imaging findings were correlated. Results: Retinal images with all three cameras were obtained on four eyes. Optos could be performed on all four eyes, RetCam on three, and Panoret on two. The field of view was comparable between the three different cameras. The best quality images were obtained with Optos. The external illumination of the Panoret made it impossible to image the only darkly pigmented individual in the series. Both contact devices failed to image another patient who was too agitated. Two patients had some ocular irritation from the coupling agent that resolved with replacement of the contact lens. Optos images were obtained on an additional six eyes, and findings correlated well with those on B-scan. Optos was superior to B-scan in an eye with silicone oil filling. Conclusion: Wide-angle fundus imaging through the keratoprosthesis is possible, and all three cameras performed similarly. The good quality of pictures obtained with the noncontact Optos, as well as its ease of use, comfort, and safety make it a preferred choice. Optos complements B-scan in the examination of the peripheral retina through the keratoprosthesis, and it may even be superior in certain settings.
引用
收藏
页码:1188 / 1192
页数:5
相关论文
共 50 条
  • [1] Biomicroscopic wide-angle imaging of fundus with digital imaging system
    Hwang, J
    Lee, JM
    Park, YS
    Choi, CY
    Lee, BR
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [2] FUNDUS HOLOGRAPHY THROUGH A WIDE-ANGLE CONTACT-LENS
    ROSEN, AN
    [J]. INVESTIGATIVE OPHTHALMOLOGY, 1973, 12 (10): : 786 - 788
  • [3] SIMPLIFIED WIDE-ANGLE PHOTOGRAPHY OF THE OCULAR FUNDUS
    RONNERSTAM, RA
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1979, : 53 - 53
  • [4] WIDE-ANGLE FUNDUS PHOTO-ILLUSTRATION
    NUSSBAUM, JJ
    SCHEPENS, CL
    PRUETT, RC
    [J]. OPHTHALMIC SURGERY AND LASERS, 1984, 15 (07): : 588 - 589
  • [5] Wide-angle lens miniaturization through foveated imaging
    Dallaire, Xavier
    Thibault, Simon
    [J]. OPTICAL SYSTEMS DESIGN 2015: OPTICAL DESIGN AND ENGINEERING VI, 2015, 9626
  • [6] EXPERIENCES WITH WIDE-ANGLE CAMERA FOR FUNDUS OCULI EXAMINATION
    RIEHM, E
    BUSSOW, C
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1978, 172 (03) : 401 - 401
  • [7] CIRCULATORY DISORDERS OF FUNDUS OCULI IN WIDE-ANGLE IMAGE
    BASTIAN, GO
    KLOSTERMANN, H
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1980, 177 (01) : 119 - 120
  • [8] BOSTON-UNIVERSITY WIDE-ANGLE AERIAL CAMERA
    KINGSLAKE, R
    [J]. IMAGE, 1979, 22 (04): : 31 - 32
  • [9] Analysis of wide-angle radar imaging
    Zhou, F.
    Bai, X.
    Xing, M.
    Bao, Z.
    [J]. IET RADAR SONAR AND NAVIGATION, 2011, 5 (04): : 449 - 457
  • [10] Wide-Angle Intraocular Imaging and Localization
    Bergeles, Christos
    Shamaei, Kamran
    Abbott, Jake J.
    Nelson, Bradley J.
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT I, PROCEEDINGS, 2009, 5761 : 540 - 548