Experimental study of V-I characteristics of wire-plate electrostatic precipitators under clean air conditions

被引:18
|
作者
Khaled, Usama [1 ]
Eldein, Adel Z. [1 ]
机构
[1] Aswan Univ, Dept High Voltage Networks, Fac Energy Engn, Aswan 81528, Egypt
关键词
Precipitator; Corona; Simulation; Wire; Plate; CALCULATING ELECTRICAL CONDITIONS; SIMULATION; MODEL;
D O I
10.1016/j.elstat.2012.12.023
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper a laboratory-scale model for prediction of the voltage-current characteristics of wire-plate electrostatic precipitators under clean air conditions is presented and experimentally validated. The model investigates the effect of electrode configurations, wire diameter, spacing between wire electrodes, number of discharge wires and distance between collecting plates that on voltage-current characteristic of wire-plate electrostatic precipitators. Also, this paper presents a simulation model, based on the Finite Difference Method (FDM), to simulate electric conditions of wire-plate electrostatic precipitators under clean air conditions. The experimental results of some models are compared with those obtained from the simulation models. Crown Copyright (C) 2012 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:228 / 234
页数:7
相关论文
共 21 条
  • [1] Experimental and Simulation Study of V-I Characteristics of Wire-Plate Electrostatic Precipitators Under Clean Air Conditions
    El Dein, Adel Z.
    Usama, K.
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2014, 39 (05) : 4037 - 4045
  • [2] Experimental and Simulation Study of V–I Characteristics of Wire–Plate Electrostatic Precipitators Under Clean Air Conditions
    Adel Z. El Dein
    K. Usama
    [J]. Arabian Journal for Science and Engineering, 2014, 39 : 4037 - 4045
  • [3] Computation of V-I characteristics in electrostatic precipitators
    Buccella, C
    [J]. JOURNAL OF ELECTROSTATICS, 1996, 37 (04) : 277 - 291
  • [4] Influence of Applied Magnetic Field on a Wire-Plate Electrostatic Precipitators Under Multi-Field Coupling
    Zhang, Jian-Ping
    Dai, Yong-Xia
    Wu, Jiong-Lei
    Ren, Jian-Xing
    Wu, Helen
    Ding, Quan-Fei
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (08):
  • [5] NEGATIVE CORONA IN WIRE-PLATE ELECTROSTATIC PRECIPITATORS. PART II: CALCULATION OF ELECTRICAL CHARACTERISTICS OF CONTAMINATED DISCHARGE ELECTRODES.
    McLean, Kenneth J.
    Lawless, Phil A.
    Sparks, Leslie E.
    Ramsey, Geddes H.
    [J]. 1600, (18):
  • [6] An experimental study on the performance of a single discharge wire-plate electrostatic precipitator with back corona
    Chang, CL
    Bai, HL
    [J]. JOURNAL OF AEROSOL SCIENCE, 1999, 30 (03) : 325 - 340
  • [7] An experimental study on the performance of a single discharge wire-plate electrostatic precipitator with back corona
    Inst. of Environmental Engineering, National Chiao Tung University, 75, Po-Ai St., Hsin-Chu, 30039, Taiwan
    [J]. J. Aerosol Sci., 3 (325-340):
  • [8] Experimental Study of Corona Discharge Generated in a Modified Wire-Plate Electrode Configuration for Electrostatic Process Applications
    Bendaoud, Abdelber
    Tilmatine, Amar
    Medles, Karim
    Younes, Mohamed
    Blejan, Octavian
    Dascalescu, Lucian
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (02) : 666 - 671
  • [9] Parametric Study and Optimization of Flow Characteristics of Wire-Nonparallel Plate-Type Electrostatic Air Accelerators
    Zhang, J. F.
    Wang, S.
    Li, H. Y.
    Qu, Z. G.
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (10):
  • [10] Determining V-I characteristics of energy-efficient electrostatic assisted air filtration system by utilizing the back-corona induced current model
    Feng Z.
    Cao S.-J.
    Long Z.
    [J]. Energy and Built Environment, 2023, 4 (02) : 227 - 235