Vapor hydration of SON68 glass from 90 °C to 200 °C: A kinetic study and corrosion products investigation

被引:56
|
作者
Neeway, James [1 ]
Abdelouas, Abdesselam [1 ]
Grambow, Bernd [1 ]
Schumacher, Stephan [2 ]
Martin, Christelle [2 ]
Kogawa, Masashi [3 ]
Utsunomiya, Satoshi [3 ]
Gin, Stephane [4 ]
Frugier, Pierre [4 ]
机构
[1] Univ Nantes, SUBATECH, Ecole Mines Nantes, IN2P3,CNRS, F-44307 Nantes, France
[2] ANDRA, F-92298 Chatenay Malabry, France
[3] Kyushu Univ, Dept Chem, Fac Sci, Fukuoka 8128581, Japan
[4] CEA Marcoule DTCD SECM LCLT, F-30207 Bagnols Sur Ceze, France
关键词
Vapor hydration; SON68; Geological disposal; NUCLEAR-WASTE GLASS; FLOW-THROUGH EXPERIMENTS; LONG-TERM BEHAVIOR; ALKALINE MEDIA; SURFACE-LAYERS; ELECTRON-MICROSCOPY; BOROSILICATE-GLASS; GRAAL MODEL; DISSOLUTION; WATER;
D O I
10.1016/j.jnoncrysol.2012.07.020
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Corrosion of nuclear waste glass in unsaturated conditions is expected to occur upon the closure of the repository galleries during disposal cell saturation in the proposed French disposal site. The objectives of the present work were to determine the alteration kinetics of the SON68 reference in such conditions. Vapor hydration tests were conducted using thin, polished SON68 glass coupons contained in stainless steel autoclaves. Temperatures ranged between 90 degrees C and 200 degrees C and the relative humidity (RH) was maintained at 91 +/- 1%. Additional experiments at 175 degrees C and 80, 85, 90 and 95% RH were also conducted to assess the role of RH on the glass corrosion rate. The nature and extent of corrosion have been determined by characterizing the reacted glass surface with scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy dispersive X-ray spectroscopy (EDS). Elemental profiling of the glass hydrated at 90 C was studied by TOF-SIMS. The chemical composition of the external layer depends on experimental conditions. The hydration rate at 90 C (TOF-SIMS analysis) is 10 x higher than the generally accepted final rate of SON68 in water at 90 degrees C (similar to 10(-4) g m(-2) d(-1)). This may indicate that the glass hydration process cannot be simulated by experiments in aqueous solution with a high S/V ratio. Subsequent leaching (corrosion in an aqueous solution) of samples weathered in water vapor showed dissolution rate values higher than those of pristine glass. This result indicates that mobile elements are trapped within the alteration products during the hydration step and it gives insight into mobility variations of the considered elements. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:2894 / 2905
页数:12
相关论文
共 26 条
  • [1] The role of pH in the vapor hydration at 175 °C of the French SON68 glass
    Chaou, Abdelouahed Ait
    Abdelouas, Abdesselam
    El Mendili, Yassine
    Martin, Christelle
    APPLIED GEOCHEMISTRY, 2017, 76 : 22 - 35
  • [2] Analytical electron microscopy study of surface layers formed on the French SON68 nuclear waste glass during vapor hydration at 200°C
    Gong, WL
    Wang, LM
    Ewing, RC
    Vernaz, E
    Bates, JK
    Ebert, WL
    JOURNAL OF NUCLEAR MATERIALS, 1998, 254 (2-3) : 249 - 265
  • [3] The French SON68 glass vapor hydration under different atmospheres
    Chaou, Abdelouahed Ait
    Abdelouas, Abdesselam
    El Mendili, Yassine
    Bouakkaz, Rachid
    Martin, Christelle
    2ND INTERNATIONAL SUMMER SCHOOL ON NUCLEAR GLASS WASTEFORM: STRUCTURE, PROPERTIES AND LONG-TERM BEHAVIOR (SUMGLASS 2013), 2014, 7 : 179 - 185
  • [4] Leach testing at 50 °C of α-doped SON68 glass alteration gels
    Jollivet, P
    Parisot, G
    JOURNAL OF NUCLEAR MATERIALS, 2005, 345 (01) : 46 - 64
  • [5] Short communication on the Influence of the temperature between 30 and 70°C on the hydration of SON68 nuclear waste glass in a vapour phase
    Jegou, Christophe
    Narayanasamy, Sathya
    Angeli, Frederic
    JOURNAL OF NUCLEAR MATERIALS, 2021, 545
  • [6] Secondary phase formation and the microstructural evolution of surface layers during vapor phase alteration of the French SON68 nuclear waste glass at 200 degrees C
    Gong, WL
    Ewing, RC
    Wang, LM
    Vernaz, E
    Bates, JK
    Ebert, WL
    SCIENTIFIC BASIS FOR NUCLEAR WASTE MANAGEMENT XIX, 1996, 412 : 197 - 204
  • [7] Effect of clayey groundwater on the dissolution rate of SON68 simulated nuclear waste glass at 70 °C
    De Echave, T.
    Tribet, M.
    Jollivet, P.
    Marques, C.
    Gin, S.
    Jegou, C.
    JOURNAL OF NUCLEAR MATERIALS, 2018, 503 : 279 - 289
  • [8] Transport- and surface reaction-controlled SON68 glass dissolution at 30°C and 70°C and pH=13.7
    Liu, Sanheng
    Ferrand, Karine
    Lemmens, Karel
    APPLIED GEOCHEMISTRY, 2015, 61 : 302 - 311
  • [9] Experimentally determined dissolution kinetics of SON68 glass at 90 °C over a silica saturation interval: Evidence against a linear rate law
    Icenhower, Jonathan P.
    Steefel, Carl I.
    JOURNAL OF NUCLEAR MATERIALS, 2013, 439 (1-3) : 137 - 147
  • [10] Long-term corrosion of two nuclear waste reference glasses (MW and SON68): A kinetic and mineral alteration study
    Curti, E.
    Crovisier, J. L.
    Morvan, G.
    Karpoff, A. M.
    APPLIED GEOCHEMISTRY, 2006, 21 (07) : 1152 - 1168