Good test-retest reliability of a paired-pulse transcranial magnetic stimulation protocol to measure short-interval intracortical facilitation

被引:9
|
作者
Qasem, H. [1 ]
Fujiyama, H. [1 ]
Rurak, B. K. [1 ]
Vallence, Ann-Maree [1 ]
机构
[1] Murdoch Univ, Coll Sci Hlth Engn & Educ, Discipline Psychol, 90 South St, Murdoch, WA 6150, Australia
基金
澳大利亚研究理事会;
关键词
Primary motor cortex; Transcranial magnetic stimulation; Short-interval intracortical facilitation; Reliability; Motor control; HUMAN MOTOR CORTEX; SHORT-LATENCY FACILITATION; I-WAVE INTERACTION; CORTICOSPINAL EXCITABILITY; INHIBITION; VARIABILITY; TMS; REPRODUCIBILITY; POTENTIALS; MODULATION;
D O I
10.1007/s00221-020-05926-4
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Transcranial magnetic stimulation (TMS) is used frequently to study human physiology, including the indirect-wave (I-wave) circuits generating short-interval intracortical facilitation (SICF). Growing evidence implicates SICF in plasticity and motor learning, suggesting that SICF is likely of functional relevance in both health and disease. To date, test-retest reliability has not been established for measures of SICF: given the clear potential of SICF to be used as a diagnostic tool, it is critical to establish the reliability of the paired-pulse TMS protocol to measure SICF. We investigated the test-retest reliability of SICF measured using paired-pulse TMS.SICF was measured in two sessions in 20 young adults using single- and paired-pulse TMS. Single-pulse TMS was set at an intensity that elicited MEPs of 1 mV (SI1mV) and paired-pulse TMS was set with the first stimulus at SI1mV, the second stimulus (S2) 90% of resting motor threshold (RMT), and a total of 20 interstimulus intervals (ISI; 1.1-4.9 ms with a 0.2 ms step). Large intraclass correlation coefficients (ICC) indicate good test-retest reliability between sessions for all SICF peaks (ICCs ranging from 0.73 to 0.79). The ISI at which SICF was maximal within individuals was consistent at all three peaks across both experimental sessions. Results showed good test-retest reliability of SICF at all three peaks when using a standard paired-pulse protocol to measure SICF. This finding suggests that paired-pulse TMS can be used to reliably probe the excitability of the interneuronal circuits that generate SICF. This provides a strong platform for future research to investigate the functional role of I-wave circuitry, including the role of I-wave circuitry in motor control decline in healthy older adults and individuals with movement disorders.
引用
收藏
页码:2711 / 2723
页数:13
相关论文
共 47 条
  • [1] Good test–retest reliability of a paired-pulse transcranial magnetic stimulation protocol to measure short-interval intracortical facilitation
    H. Qasem
    H. Fujiyama
    B. K. Rurak
    Ann-Maree Vallence
    Experimental Brain Research, 2020, 238 : 2711 - 2723
  • [2] Test-retest reliability of short-interval intracortical inhibition and intracortical facilitation in patients with schizophrenia
    Du Xiaoming
    Elliot, Hong L.
    PSYCHIATRY RESEARCH, 2018, 267 : 575 - 581
  • [3] Influence of Waveform and Current Direction on Short-Interval Intracortical Facilitation: A Paired-Pulse TMS Study
    Delvendahl, Igor
    Lindemann, Hannes
    Jung, Nikolai H.
    Pechmann, Astrid
    Siebner, Hartwig R.
    Mall, Volker
    BRAIN STIMULATION, 2014, 7 (01) : 49 - 58
  • [4] Investigation of the primary visual cortex using short-interval paired-pulse transcranial magnetic stimulation (TMS)
    Sparing, R
    Dambeck, N
    Stock, K
    Meister, IG
    Huetter, D
    Boroojerdi, B
    NEUROSCIENCE LETTERS, 2005, 382 (03) : 312 - 316
  • [5] Test-retest reliability of single and paired pulse transcranial magnetic stimulation parameters in healthy subjects
    Hermsen, A. M.
    Haag, A.
    Duddek, C.
    Balkenhol, K.
    Bugiel, H.
    Bauer, S.
    Mylius, V.
    Menzler, K.
    Rosenow, F.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2016, 362 : 209 - 216
  • [6] Reliability of Novel Paired-Pulse Transcranial Magnetic Stimulation for Assessment of Intracortical Quadriceps Activation
    Thomas, Abbey C.
    Pietrosimone, Brian G.
    Bayer, Carter J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 674 - 674
  • [7] Test-Retest Reliability of Short-Interval Intracortical Inhibition Assessed by Threshold-Tracking and Automated Conventional Techniques
    Nielsen, Christina S-Z
    Samusyte, Gintaute
    Pugdahl, Kirsten
    Blicher, Jakob U.
    Fuglsang-Frederiksen, Anders
    Cengiz, Bulent
    Tankisi, Hatice
    ENEURO, 2021, 8 (05)
  • [8] Paired-Pulse TMS and Fine-Wire Recordings Reveal Short-Interval Intracortical Inhibition and Facilitation of Deep Multifidus Muscle Fascicles
    Masse-Alarie, Hugo
    Cancino, Edith Elgueta
    Schneider, Cyril
    Hodges, Paul
    PLOS ONE, 2016, 11 (08):
  • [9] Short-interval paired-pulse inhibition and facilitation of human motor cortex: the dimension of stimulus intensity
    Ilic, TV
    Meintzschel, F
    Cleff, U
    Ruge, D
    Kessler, KR
    Ziemann, U
    JOURNAL OF PHYSIOLOGY-LONDON, 2002, 545 (01): : 153 - 167
  • [10] Mechanisms of intracortical I-wave facilitation elicited with paired-pulse magnetic stimulation in humans
    Hanajima, R
    Ugawa, Y
    Terao, Y
    Enomoto, H
    Shiio, Y
    Mochizuki, H
    Furubayashi, T
    Uesugi, H
    Iwata, NK
    Kanazawa, I
    JOURNAL OF PHYSIOLOGY-LONDON, 2002, 538 (01): : 253 - 261