A new method for the simultaneous measurement of aerosol particle size, complex refractive index and particle density

被引:38
|
作者
Szymanski, WW
Nagy, A
Czitrovszky, A
Jani, P
机构
[1] Univ Vienna, Inst Expt Phys, Aerosol Lab, A-1090 Vienna, Austria
[2] Res Inst Solid State Phys & Opt, Dept Laser Applicat, H-1525 Budapest, Hungary
关键词
light scattering; particle sizing; refractive index; optical detection; particle density;
D O I
10.1088/0957-0233/13/3/311
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Particle size measurement by means of optical spectrometry of single particles depends substantially on the angular range of light scattering and the refractive index of the particle. Knowledge of the latter determines implicitly the accuracy of measurement. In contrast to commonly used instrumental systems the configuration of the design concept presented here consists of two laser illumination sources with different wavelengths and four angular ranges for the collection of scattered light. As a result a set of four independent pulses from each measured particle can be obtained allowing simultaneous assessment of particle size and its complex refractive index. Based on the Mie theory of light scattering, light collection angles yielding a single-valued aerosol size measurement were identified and used to design a new optical system. Based on the modelling of the performance for an assumed instrumental arrangement the sizing errors were found to be about 2%. The accuracy of assessment of the complex index of refraction was found to be of the order of 10% over the range of particle diameters investigated (0.1-10 mum). The theoretical results show clearly the capability of this novel instrumental design for the measurement of aerosol particle sizes, their density and optical properties. Based on these model calculations an experimental set-up is under construction.
引用
收藏
页码:303 / 307
页数:5
相关论文
共 50 条
  • [1] Simultaneous inversion of dust aerosol complex refractive index and particle morphology with measurement of aerosol Stokes parameters
    Ma, Xirui
    Zhao, Hu
    Zeng, Yazheng
    Gao, Siqi
    Cheng, Jiyuan
    He, Qiangqiang
    Mao, Jiandong
    Zhou, Chunyan
    Gong, Xin
    Rao, Zhimin
    [J]. OPTICS AND LASERS IN ENGINEERING, 2023, 171
  • [2] A new method for retrieving particle refractive index and effective density from aerosol size distribution data
    Hand, JL
    Kreidenweis, SM
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2002, 36 (10) : 1012 - 1026
  • [3] Simultaneous retrieval of the complex refractive index and particle size distribution
    Ren, Yatao
    Qi, Hong
    Chen, Qin
    Ruan, Liming
    Tan, Heping
    [J]. OPTICS EXPRESS, 2015, 23 (15): : 19328 - 19337
  • [4] Measurement of refractive index for aerosol particle in Xiamen
    Li, Xue-Bin
    Huang, Yin-Bo
    Xu, Chi-Dong
    Wei, He-Li
    Hu, Huan-Ling
    [J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2008, 16 (10): : 1831 - 1835
  • [5] Approach to a simultaneous assessment of aerosol particle size and refractive index by multiple angle detection
    [J]. Czitrovszky, A., 1600, Elsevier Science Ltd, Exeter, United Kingdom (31):
  • [7] SIMULTANEOUS MEASUREMENT OF SIZE AND REFRACTIVE-INDEX OF A FINE PARTICLE IN FLOWING LIQUID
    TAKEDA, K
    ITO, Y
    MUNAKATA, C
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (01) : 27 - 32
  • [8] EFFECT OF PARTICLE REFRACTIVE INDEX ON THE ACCURACY OF AEROSOL MEASUREMENT WITH OPTICAL PARTICLE COUNTERS
    胡欢陵
    赵凤生
    龚知本
    [J]. Science Bulletin, 1988, (05) : 428 - 432
  • [9] Measurement of particle size and refractive index based on interferometric particle imaging
    Yao, KunYuan
    Shen, JianQi
    [J]. OPTICS AND LASER TECHNOLOGY, 2021, 141
  • [10] Accurate in situ measurement of complex refractive index and particle size in intralipid emulsions
    Dong, Miao L.
    Goyal, Kashika G.
    Worth, Bradley W.
    Makkar, Sorab S.
    Calhoun, William R.
    Bali, Lalit M.
    Bali, Samir
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (08)