Concentration modulated skin marker for radiotherapy treatment planning process

被引:0
|
作者
Ozguven, Yildiray [1 ]
Yucel, Birsen [1 ]
Ozyurek, Betul [1 ]
Karakus, Gulderen [2 ]
Ozguven, Yucel [3 ]
机构
[1] Cumhuriyet Univ, Fac Med, Dept Radiat Oncol, TR-58140 Sivas, Turkey
[2] Cumhuriyet Univ, Fac Med, CUTFAMRCCUSM, TR-58140 Sivas, Turkey
[3] Cumhuriyet Univ, Dept Phys, TR-58140 Sivas, Turkey
来源
关键词
Skin marker; Electron beam; Dose deviation; Barium sulfate; ARTIFACT SUPPRESSION;
D O I
10.1016/j.ejmp.2012.03.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and purpose: For conformal radiotherapy, it is feasible to achieve high accuracy in contouring the outline of the target volume in treatment planning process. In contouring process, target volume is occasionally defined by means of either surgical clips or skin marker during patient anatomical data acquisition. Treatment planning systems are predicting invalid radiation dose distributions by using surgical clips and skin marker within the patient. Purpose of this study is the production of new skin marker which affects less dose distributions of electron beam. Materials and methods: The influences of lead and commercial markers on dose calculations in a 3D treatment planning systems were investigated in terms of electron beam energy and dose profile depth. Dose deviation with commercial marker was observed to smaller than lead marker. However this dose deviation was still at big value. In order to reduce of this value, barium sulfate suspension and ultrasound gel were mixed with different volumetric ratio. With the purpose of acception the most suitable marker for radiation therapy, obtained new suspensions were investigated in terms of visibility and dose deviation. Results: B:G/1:10 marker was determined to cause optimum visibility and the lowest dose deviation on dose calculations in terms of electron beam energy and dose profile depth. Conclusions: Appropriate marker, mixture of substances such as barium sulfate suspension and ultrasound gel can be produced. This marker is both ease of usage and practical and economical. Each clinic can prepare marker which is peculiar to suspension with different concentration of substance for specific visibility. But, it should be taken into account resultant dose deviation to beam calculation depending on barium sulfate concentration. (C) 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:196 / 203
页数:8
相关论文
共 50 条
  • [1] Evaluation of An Automated Treatment Planning Verification System for Intensity-Modulated Radiotherapy Treatment Planning
    Xiao, L.
    Yin, Y.
    Tong, L. Xiu
    MEDICAL PHYSICS, 2017, 44 (06) : 2897 - 2897
  • [2] Optimizing the radiotherapy treatment planning process for glioblastoma
    Kotecha, Rupesh R.
    Mehta, Minesh P.
    NEURO-ONCOLOGY PRACTICE, 2022, 9 (05) : 351 - 353
  • [3] Intensity-modulated radiotherapy: Rethinking basic treatment planning paradigms
    Macklis, R
    Weinhous, M
    Harnisch, G
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02): : 317 - 318
  • [4] Inverse treatment planning for modulated electrons and mixed photon and electron radiotherapy
    Alexander, A.
    Seuntjens, J.
    MEDICAL PHYSICS, 2012, 39 (07) : 4622 - 4622
  • [5] Planning tools for modulated electron radiotherapy
    Surucu, Murat
    Klein, Eric E.
    Mamalui-Hunter, Maria
    Mansur, David B.
    Low, Daniel A.
    MEDICAL PHYSICS, 2010, 37 (05) : 2215 - 2224
  • [6] Aperture generation based on threshold segmentation for intensity modulated radiotherapy treatment planning
    Yang, Jie
    Gui, Zhiguo
    Zhang, Liyuan
    Zhang, Pengcheng
    MEDICAL PHYSICS, 2018, 45 (04) : 1758 - 1770
  • [7] Quality assurance of intensity-modulated radiotherapy treatment planning: a dosimetric comparison
    Altaf, Saima
    Iqbal, Khalid
    Akram, Muhammad
    Buzdar, Saeed A.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (04) : 396 - 402
  • [8] Corticospinal tract-sparing intensity-modulated radiotherapy treatment planning
    Igaki, Hiroshi
    Sakumi, Akira
    Mukasa, Akitake
    Saito, Kuniaki
    Kunimatsu, Akira
    Masutani, Yoshitaka
    Hanakita, Shunya
    Ino, Kenji
    Haga, Akihiro
    Nakagawa, Keiichi
    Ohtomo, Kuni
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2014, 19 (05) : 310 - 316
  • [9] Effects of multileaf collimator parameters on treatment planning of intensity-modulated radiotherapy
    Wu, Vincent W. C.
    MEDICAL DOSIMETRY, 2007, 32 (01) : 38 - 43
  • [10] A treatment planning inter-comparison of proton and intensity modulated photon radiotherapy
    Lomax, AJ
    Bortfeld, T
    Goitein, G
    Debus, J
    Dykstra, C
    Tercier, PA
    Coucke, PA
    Mirimanoff, RO
    RADIOTHERAPY AND ONCOLOGY, 1999, 51 (03) : 257 - 271