Advanced multi-contrast Jones matrix optical coherence tomography for Doppler and polarization sensitive imaging

被引:98
|
作者
Ju, Myeong Jin [1 ,3 ,4 ]
Hong, Young-Joo [1 ,4 ]
Makita, Shuichi [1 ,4 ]
Lim, Yiheng [1 ,4 ]
Kurokawa, Kazuhiro [1 ,4 ]
Duan, Lian [1 ,4 ]
Miura, Masahiro [2 ]
Tang, Shuo [3 ]
Yasuno, Yoshiaki [1 ,4 ]
机构
[1] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki, Japan
[2] Tokyo Med Univ, Ibaraki Med Ctr, Dept Ophthalmol, Ami, Ibaraki, Japan
[3] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V5Z 1M9, Canada
[4] Computat Opt & Ophthalmol Grp, Tsukuba, Ibaraki, Japan
来源
OPTICS EXPRESS | 2013年 / 21卷 / 16期
基金
日本学术振兴会;
关键词
RETINAL BLOOD-FLOW; NERVE-FIBER LAYER; IN-VIVO; CLINICAL-APPLICATION; HUMAN SKIN; BIREFRINGENCE; TISSUE; EYE; MICROSCOPY; AGE;
D O I
10.1364/OE.21.019412
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An advanced version of Jones matrix optical coherence tomography (JMT) is demonstrated for Doppler and polarization sensitive imaging of the posterior eye. JMT is capable of providing localized flow tomography by Doppler detection and investigating the birefringence property of tissue through a three-dimensional (3-D) Jones matrix measurement. Owing to an incident polarization multiplexing scheme based on passive optical components, this system is stable, safe in a clinical environment, and cost effective. Since the properties of this version of JMT provide intrinsic compensation for system imperfection, the system is easy to calibrate. Compared with the previous version of JMT, this advanced JMT achieves a sufficiently long depth measurement range for clinical cases of posterior eye disease. Furthermore, a fine spectral shift compensation method based on the cross-correlation of calibration signals was devised for stabilizing the phase of OCT, which enables a high sensitivity Doppler OCT measurement. In addition, a new theory of JMT which integrates the Jones matrix measurement, Doppler measurement, and scattering measurement is presented. This theory enables a sensitivity-enhanced scattering OCT and high-sensitivity Doppler OCT. These new features enable the application of this system to clinical cases. A healthy subject and a geographic atrophy patient were measured in vivo, and simultaneous imaging of choroidal vasculature and birefringence structures are demonstrated. (c) 2013 Optical Society of America
引用
收藏
页码:19412 / 19436
页数:25
相关论文
共 50 条
  • [1] Multi-contrast imaging of human posterior eye by Jones matrix optical coherence tomography
    Yasuno, Yoshiaki
    BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2017, 10251
  • [2] Three-Dimensional Polarization and Doppler Imaging of Living tissue by Multi-Contrast Optical Coherence Tomography
    Yasuno, Yoshiaki
    Hong, Young-Joo
    Ju, Myeong-Jin
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2013,
  • [3] Three-dimensional multi-contrast imaging of in vivo human skin by Jones matrix optical coherence tomography
    Li, En
    Makita, Shuichi
    Hong, Young-Joo
    Kasaragod, Deepa
    Yasuno, Yoshiaki
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (03): : 1290 - 1305
  • [4] High-speed 1-μm Jones-matrix Multi-contrast Optical Coherence Tomography for Simultaneous 3D Doppler and Polarization Imaging
    Hong, Young-Joo
    Miura, Masahiro
    Makita, Shuichi
    Yasuno, Yoshiaki
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [5] Multi-Contrast Jones-Matrix Optical Coherence Tomography-The Concept, Principle, Implementation, and Applications
    Yasuno, Yoshiaki
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2023, 29 (04)
  • [6] Quantitative multi-contrast in vivo mouse imaging with polarization diversity optical coherence tomography and angiography
    Hsu, Destiny
    Kwon, Ji Hoon
    Ng, Ringo
    Makita, Shuichi
    Yasuno, Yoshiaki
    Sarunic, Marinko V.
    Ju, Myeong Jin
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (12): : 6945 - 6961
  • [7] Skin Layer Structure Characterization via Multi-Contrast Polarization-Sensitive Optical Coherence Tomography
    Maloufi, Sina
    Zhou, Xin
    Tang, Shuo
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXVI, 2022, 11948
  • [8] Passive component based multifunctional Jones matrix swept source optical coherence tomography for Doppler and polarization imaging
    Lim, Yiheng
    Hong, Young-Joo
    Duan, Lian
    Yamanari, Masahiro
    Yasuno, Yoshiaki
    OPTICS LETTERS, 2012, 37 (11) : 1958 - 1960
  • [9] Quantitative Imaging of Tissue Polarization Property by Jones Matrix Optical Coherence Tomography
    Yasuno, Yoshiaki
    2015 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2015,
  • [10] Polarization-sensitive complex Fourier domain optical coherence tomography for Jones matrix imaging of biological samples
    Yasuno, Y
    Makita, S
    Endo, T
    Itoh, M
    Yatagai, T
    Takahashi, M
    Katada, C
    Mutoh, M
    APPLIED PHYSICS LETTERS, 2004, 85 (15) : 3023 - 3025