THE DETERMINATION OF THE MEAN VALUE OF THE NON-HOMOGENOUS BACKGROUND RADIATION AND THE MEASUREMENT UNCERTAINTY USING WELCH-SATTERTHWAITE EQUATION

被引:19
|
作者
Kartalovic, Nenad M. [1 ]
Stojic, Tomislav M. [2 ]
Brajovic, Dragan V. [3 ]
Osmokrovic, Predrag V. [4 ]
机构
[1] Inst Elect Engn Nikola Tesla, Belgrade, Serbia
[2] Univ Belgrade, Fac Mech Engn, Belgrade, Serbia
[3] High Sch Tech Sci, Cacak, Serbia
[4] State Univ Novi Pazar, Novi Pazar, Serbia
来源
NUCLEAR TECHNOLOGY & RADIATION PROTECTION | 2017年 / 32卷 / 04期
关键词
GM counter; non-homogenous background radiation; measurement uncertainty;
D O I
10.2298/NTRP1704371K
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this paper, the procedure for determination of the mean value of non-homogenous background radiation and the expression of measurement uncertainty is considered. The background radiation is described using the Student's distribution, and the measurement uncertainty using the Welch-Satterthwaite equation. The proposed algorithm was experimentally verified under well-controlled laboratory conditions and satisfactory results were obtained.
引用
收藏
页码:371 / 374
页数:4
相关论文
共 1 条
  • [1] Quantifying Uncertainty in Estimations of the Total Weight of Drugs in Groups of Complex Matrices: Using the Welch-Satterthwaite Equation
    Alberink, Ivo
    Sprong, Annette
    Bolck, Annabel
    Vergeer, Peter
    JOURNAL OF FORENSIC SCIENCES, 2017, 62 (04) : 1007 - 1014