MRI-compatible rigid and flexible outer sheath device with pneumatic locking mechanism for minimally invasive surgery

被引:0
|
作者
Zuo, Siyang [1 ]
Yamanaka, Noriaki [1 ]
Sato, Ikuma
Masamune, Ken [1 ]
Liao, Hongen [2 ]
Matsumiya, Kiyoshi [1 ]
Dohi, Takeyoshi [1 ]
机构
[1] Univ Tokyo, Grad Sch Informat Sci & Technol, 2-2 Kanda Nishiki Cho, Tokyo 1018457, Japan
[2] Univ Tokyo, Grad Sch Technol, Tokyo 1138654, Japan
关键词
outer sheath; pneumatic locking mechanism; minimally invasive surgery; MRI;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
To reduce the invasiveness of surgery, we developed an outer sheath device using a flexible toothed link and pneumatic locking mechanism that works with flexible devices used in minimally invasive surgery. The outer sheath can be switched between flexible and rigid modes, and the angle of its tip can be controlled by a nylon wire. All parts of this device are made of plastic and are MRI-compatible. We manufactured a sheath prototype, 300 mm long, with a 20-mm outer diameter, and an 8-mm inner diameter. Experiment results showed that the outer sheath can protect tissues from high insertion force and secure the path for flexible devices. It can follow a curved path with a reasonable radius.
引用
收藏
页码:210 / +
页数:3
相关论文
共 20 条
  • [1] MRI Compatible Rigid-flexible Outer Sheath Device Using Pneumatic Locking Mechanism for Endoscopic Treatment
    Zuo, Siyang
    Ymanaka, N.
    Masamune, K.
    Liao, H.
    Matsumiya, K.
    Dohi, T.
    APCMBE 2008: 7TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, 2008, 19 : 741 - +
  • [2] Nonmagnetic Rigid and Flexible Outer Sheath with Pneumatic Interlocking Mechanism for Minimally Invasive Surgical Approach
    Yamashita, Hiromasa
    Zuo, Siyang
    Masamune, Ken
    Liao, Hongen
    Dohi, Takeyoshi
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT I, PROCEEDINGS, 2009, 5761 : 418 - +
  • [3] Nonmetallic Rigid-Flexible Outer Sheath with Pneumatic Shape locking Mechanism and Double Curvature Structure
    Zuo, Siyang
    Masamune, Ken
    Kuwana, Kenta
    Tomikawa, Morimasa
    Ieiri, Satoshi
    Ohdaira, Takeshi
    Hashizume, Makoto
    Dohi, Takeyoshi
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 169 - +
  • [4] Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast
    Larson, BT
    Erdman, AG
    Tsekos, NV
    Yacoub, E
    Tsekos, PV
    Koutlas, LG
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (04): : 458 - 465
  • [5] MRI-compatible ultrasonic probe for minimally invasive therapy
    Azuma, T
    Sasaki, K
    Kawabata, KI
    Osada, A
    Itagaki, H
    Komura, K
    Takahashi, T
    Ishida, K
    Satoh, Y
    Umemura, SI
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1465 - 1468
  • [6] Rigid-flexible outer sheath model using slider linkage locking mechanism and air pressure for endoscopic surgery
    Yagi, Akihiko
    Matsumiya, Kiyoshi
    Masamune, Ken
    Liao, Hongen
    Dohi, Takeyoshi
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 1, 2006, 4190 : 503 - 510
  • [7] A new MRI-compatible optical fiber tactile sensor for use in minimally invasive robotic surgery systems
    Ahmadi, Roozbeh
    Dargahi, Javad
    Packirisamy, Muthukumaran
    Cecere, Renzo
    FOURTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2010, 7653
  • [8] TOWARDS THE DEVELOPMENT OF A LOW-COST MINIMALLY INVASIVE HIGHLY ARTICULATED MRI-COMPATIBLE NEUROSURGICAL ROBOT
    Chowdhury, Sagar
    Desai, Jaydev P.
    Diakite, Mahamadou
    Shin, Taehoon
    Gullapalli, Rao P.
    Gupta, Satyandra K.
    7TH ANNUAL DYNAMIC SYSTEMS AND CONTROL CONFERENCE, 2014, VOL 3, 2014,
  • [9] Variable stiffness outer sheath with “Dragon skin” structure and negative pneumatic shape-locking mechanism
    Siyang Zuo
    Kazuo Iijima
    Takahiro Tokumiya
    Ken Masamune
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 857 - 865
  • [10] Variable stiffness outer sheath with "Dragon skin" structure and negative pneumatic shape-locking mechanism
    Zuo, Siyang
    Iijima, Kazuo
    Tokumiya, Takahiro
    Masamune, Ken
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (05) : 857 - 865