An absolute radon 222 activity measurement system at LNE-LNHB

被引:10
|
作者
Sabot, B. [1 ]
Pierre, S. [1 ]
Cassette, P. [1 ]
机构
[1] CEA, LIST, Lab Natl Henri Becquerel LNE LNHB, Ctr Saclay, F-91191 Gif Sur Yvette, France
关键词
Rn-222; Po-218; Po-214; Radon; Primary standard; STANDARDIZATION; RN-222;
D O I
10.1016/j.apradiso.2016.09.009
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A good metrological traceability of radon and progenies is necessary to accurately measure the radon concentration. In 1995, at the LNE-LNHB, J.L. Picolo developed a reference method using a defined-solid angle (DSA) alpha spectrometer to measure a frozen radon source. With this method it was possible to measure radon standards with a relative standard uncertainty of 0.5%. This paper presents the design and the characterization of a new upgraded measurement system; all parameters and their uncertainties are discussed. This new system allows the measurement of radon sources from 100 Bq to 4 MBq with a relative standard uncertainty of 0.3%.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [1] Performance of portable TDCR systems developed at LNE-LNHB
    Sabot, Benoit
    Dutsov, Chavdar
    Cassette, Philippe
    Mitev, Krasimir
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1034
  • [2] Absolute measurement of radon 222 activity
    Picolo, JL
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (2-3): : 452 - 457
  • [3] 3H activity comparison between FTMC, VNIIM and LNE-LNHB
    Cassette, Philippe
    Butkus, Paulius
    Gudelis, Arunas
    Shilnikova, Tatiana
    [J]. APPLIED RADIATION AND ISOTOPES, 2016, 109 : 41 - 43
  • [4] Update of the BIPM.RI(II)-K1.Rn-222 comparison of activity measurements for the radionuclide 222Rn to include the LNE-LNHB, France
    Michotte, C.
    Ratel, G.
    Cassette, P.
    [J]. METROLOGIA, 2012, 49
  • [5] New constant-temperature operating mode for graphite calorimeter at LNE-LNHB
    Daures, J
    Ostrowsky, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (17): : 4035 - 4052
  • [6] Some specific features of ionization chamber calibrations in linac x-ray beams at the LNE-LNHB
    Delaunay, F.
    Ostrowsky, A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (09): : N207 - N211
  • [7] Small section graphite calorimeter (GR-10) at LNE-LNHB for measurements in small beams for IMRT
    Daures, J.
    Ostrowsky, A.
    Rapp, B.
    [J]. METROLOGIA, 2012, 49 (05) : S174 - S178
  • [8] Dose area product primary standards established by graphite calorimetry at the LNE-LNHB for small radiation fields in radiotherapy
    Jurczak, Julien
    Rapp, Benjamin
    Delaunay, Frank
    Gouriou, Jean
    Dufreneix, Stephane
    Bordy, Jean-Marc
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 98 : 18 - 27
  • [9] The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays
    Rapp, B.
    Perichon, N.
    Denoziere, M.
    Daures, J.
    Ostrowsky, A.
    Bordy, J-M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (09): : 2769 - 2786
  • [10] Activity measurements of the radionuclide 111In for the LNE-LNHB, France in the ongoing comparison BIPM.RI(II)-K1.In-111
    Michotte, C.
    Ratel, G.
    Courte, S.
    Verdeau, E.
    Amiot, M. -N.
    [J]. METROLOGIA, 2010, 47