Process analytical technology in continuous manufacturing of a commercial pharmaceutical product

被引:87
|
作者
Vargas, Jenny M. [1 ,3 ]
Nielsen, Sarah [2 ]
Cardenas, Vanessa [1 ]
Gonzalez, Anthony [3 ]
Aymat, Efrain Y. [3 ]
Almodovar, Elvin [3 ]
Classe, Gustavo [3 ]
Colon, Yleana [3 ]
Sanchez, Eric [3 ]
Romanach, Rodolfo J. [1 ]
机构
[1] Univ Puerto Rico, Dept Chem, Mayaguez, PR 00682 USA
[2] Johnson & Johnson, Janssen Supply Chain, New Brunswick, NJ USA
[3] Janssen Ortho LLC Gurabo, Gurabo, PR USA
关键词
NEAR-INFRARED METHOD; IN-LINE; BLEND UNIFORMITY; FLOW PROPERTIES; CONTROL-SYSTEM; STRIP FILMS; END-POINT; SPECTROSCOPY; DISTRIBUTIONS; PERFORMANCE;
D O I
10.1016/j.ijpharm.2018.01.003
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The implementation of process analytical technology and continuous manufacturing at an FDA approved commercial manufacturing site is described. In this direct compaction process the blends produced were monitored with a Near Infrared (NIR) spectroscopic calibration model developed with partial least squares (PLS) regression. The authors understand that this is the first study where the continuous manufacturing (CM) equipment was used as a gravimetric reference method for the calibration model. A principal component analysis (PCA) model was also developed to identify the powder blend, and determine whether it was similar to the calibration blends. An air diagnostic test was developed to assure that powder was present within the interface when the NIR spectra were obtained. The air diagnostic test as well the PCA and PLS calibration model were integrated into an industrial software platform that collects the real time NIR spectra and applies the calibration models. The PCA test successfully detected an equipment malfunction. Variographic analysis was also performed to estimate the sampling analytical errors that affect the results from the NIR spectroscopic method during commercial production. The system was used to monitor and control a 28 h continuous manufacturing run, where the average drug concentration determined by the NIR method was 101.17% of label claim with a standard deviation of 2.17%, based on 12,633 spectra collected. The average drug concentration for the tablets produced from these blends was 100.86% of label claim with a standard deviation of 0.4%, for 500 tablets analyzed by Fourier Transform Near Infrared (FT-NIR) transmission spectroscopy. The excellent agreement between the mean drug concentration values in the blends and tablets produced provides further evidence of the suitability of the validation strategy that was followed.
引用
收藏
页码:167 / 178
页数:12
相关论文
共 50 条
  • [1] Process Analytical Technology: tools and applications in pharmaceutical manufacturing
    Wiss, Jacques
    [J]. CHIMICA OGGI-CHEMISTRY TODAY, 2015, 33 (02) : 30 - 33
  • [2] Raman spectroscopy as a process analytical technology for pharmaceutical manufacturing and bioprocessing
    Karen A. Esmonde-White
    Maryann Cuellar
    Carsten Uerpmann
    Bruno Lenain
    Ian R. Lewis
    [J]. Analytical and Bioanalytical Chemistry, 2017, 409 : 637 - 649
  • [3] Raman spectroscopy as a process analytical technology for pharmaceutical manufacturing and bioprocessing
    Esmonde-White, Karen A.
    Cuellar, Maryann
    Uerpmann, Carsten
    Lenain, Bruno
    Lewis, Ian R.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (03) : 637 - 649
  • [4] Process Analytical Technology, continuous manufacturing, and the development of a surrogate model for dissolution: a pharmaceutical manufacturing statistical engineering case study
    Altan, Stan
    Coppenolle, Hans
    Hare, Lynne
    Nielsen, Sarah
    Otava, Martin
    [J]. QUALITY ENGINEERING, 2023, 35 (04) : 733 - 740
  • [5] Continuous Manufacturing in Pharmaceutical Process Development and Manufacturing
    Burcham, Christopher L.
    Florence, Alastair J.
    Johnson, Martin D.
    [J]. ANNUAL REVIEW OF CHEMICAL AND BIOMOLECULAR ENGINEERING, VOL 9, 2018, 9 : 253 - 281
  • [6] Implementation of process analytical technology during process development in a pharmaceutical product pilot plant
    Kleissas, KM
    Higgins, JP
    Green, RL
    Pixley, N
    Witulski, F
    Bowen, WE
    Mateos, A
    Reed, RA
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U233 - U233
  • [7] Application of Artificial Neural Networks in the Process Analytical Technology of Pharmaceutical Manufacturing—a Review
    Brigitta Nagy
    Dorián László Galata
    Attila Farkas
    Zsombor Kristóf Nagy
    [J]. The AAPS Journal, 24
  • [8] Pharmaceutical manufacturing and the quality by design (QBD), process analytical technology (PAT) approach
    Murphy, Trevor
    O'Mahony, Niall
    Panduru, Krishna
    Riordan, Daniel
    Walsh, Joseph
    [J]. 2016 27TH IRISH SIGNALS AND SYSTEMS CONFERENCE (ISSC), 2016,
  • [9] Process analytical technology for continuous manufacturing tableting processing: A case study
    Pauli, Victoria
    Roggo, Yves
    Pellegatti, Laurent
    Nhat Quang Nguyen Trung
    Elbaz, Frantz
    Ensslin, Simon
    Kleinebudde, Peter
    Krumme, Markus
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 162 : 101 - 111
  • [10] Process Analytical Technology for continuous manufacturing of solid-dosage forms
    Fonteyne, Margot
    Vercruysse, Jurgen
    De Leersnyder, Fien
    Van Snick, Bernd
    Vervaet, Chris
    Remon, Jean Paul
    De Beer, Thomas
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2015, 67 : 159 - 166