Percutaneous endobiliary forceps biopsy of biliary strictures for histopathologic examination

被引:14
|
作者
Augustin, Anne Marie [1 ]
Steingrueber, Marcus [1 ]
Fluck, Friederika [1 ]
Goetze, Oliver [2 ]
Bley, Thorsten Alexander [1 ]
Kickuth, Ralph [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Wurzburg, Germany
[2] Univ Hosp Wurzburg, Dept Internal Med 2, Wurzburg, Germany
关键词
FINE-NEEDLE-ASPIRATION; BILE-DUCT; EUS-FNA; OBSTRUCTION; DIAGNOSIS; ERCP; CYTOLOGY; DRAINAGE; BRUSH;
D O I
10.5152/dir.2020.19329
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE We aimed to investigate the feasibility, accuracy and safety of percutaneous endobiliary cholangio-forceps biopsy of biliary strictures in our institution. METHODS A total of 13 percutaneous transhepatic endobiliary biopsies (7 men and 6 women, mean age 66.85 +/- 16.76 years) were performed between January 2015 and March 2019 using a transluminal forceps biopsy device. Technical success, rate of complications, number of biopsy specimens, procedure and fluoroscopy time, mean radiation exposure were evaluated; sensitivity and accuracy were calculated. RESULTS Technical success, i.e., acquisition of at least three (median, 3.00; range, 3-5) macroscopic representative samples, could be achieved in all 13 biopsies. Access was gained via the right liver lobe in 12 of 13 cases (92.3%). All patients presented blood work indicative of cholestasis prior the intervention, with mean bilirubin 4.72 +/- 3.72 mu mol/L, mean gamma-glutamyl transferase 574.16 +/- 360.92 IU/L, and median alkaline phosphatase 407 IU/L (165-1366 IU/L). In 12 of 13 cases (92.3%), biopsied material was sufficient for the pathologist to make a histopathologic diagnosis. Analysis revealed cases of malignancy in eight of 13 cases (61.5%), all of which turned out to be cases of cholangiocarcinoma. In four benign cases (30.8%), diagnosis was considered to be confirmed by further imaging or clinical follow-ups, which showed no signs of progressive disease. There was one case (7.7%) of a false-negative result with proof of malignancy in subsequent surgical tissue extraction. A calculation of diagnostic performance yielded a sensitivity rate of 88.9% and an accuracy rate of 92.3%. There was one case of minor and one case of major complication in our study collective, leading to an overall complication rate of 15.4%. CONCLUSION Percutaneous transhepatic biliary drainage (PTBD)-based forceps biopsy via the transhepatic drainage tract in patients with biliary obstruction of unknown origin is a technically feasible and safe technique with good diagnostic value rates. The procedure should be considered in patients not suitable for endoscopic strategies with indication for establishment of PTBD.
引用
收藏
页码:339 / 344
页数:6
相关论文
共 50 条
  • [1] Endobiliary Biopsy with Larger Forceps in Extrahepatic Biliary Strictures
    Maetani, Iruru
    Ikeda, Masaki
    Seike, Masahiro
    Tada, Tomoko
    Ukita, Takeo
    GASTROINTESTINAL ENDOSCOPY, 2006, 63 (05) : AB289 - AB289
  • [2] Percutaneous transluminal forceps biopsy: Experience in 130 patients with malignant biliary strictures
    Jung, GS
    Lee, S
    Han, B
    Chang, H
    Huh, J
    Cho, YD
    RADIOLOGY, 2001, 221 : 352 - 352
  • [3] Percutaneous transhepatic cholangiographic endobiliary forceps biopsy versus endoscopic ultrasound fine needle aspiration for proximal biliary strictures: a single-centre experience
    Mohkam, Kayvan
    Malik, Yaseen
    Derosas, Carlos
    Isaac, John
    Marudanayagam, Ravi
    Mehrzad, Homoyoon
    Mirza, Darius F.
    Muiesan, Paolo
    Roberts, Keith J.
    Sutcliffe, Robert P.
    BRITISH JOURNAL OF SURGERY, 2016, 103 : 23 - 23
  • [4] Percutaneous transhepatic cholangiographic endobiliary forceps biopsy versus endoscopic ultrasound fine needle aspiration for proximal biliary strictures: a single-centre experience
    Mohkam, Kayvan
    Malik, Yaseen
    Derosas, Carlos
    Isaac, John
    Marudanayagam, Ravi
    Mehrzad, Homoyoon
    Mirza, Darius F.
    Muiesan, Paolo
    Roberts, Keith J.
    Sutcliffe, Robert P.
    HPB, 2017, 19 (06) : 530 - 537
  • [5] THE EFFICACY OF ENDOBILIARY BIOPSY AND CEA STAINING IN EVALUATING BILIARY STRICTURES
    LO, SK
    CHANG, L
    FRENCH, S
    JUAREZ, D
    ASHBY, K
    GASTROINTESTINAL ENDOSCOPY, 1993, 39 (02) : 324 - 324
  • [6] Percutaneous endobiliary radiofrequency ablation for refractory benign hepaticojejunostomy and biliary strictures
    Ozdemir, M.
    Kucukay, F.
    Ozdemir, F. A. E.
    Acu, R.
    Tola, M.
    Yurdakul, M.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (09) : 555 - 560
  • [7] Comparison of Biliary Brush Cytology and Forceps Biopsy in the Diagnosis of Malignant Biliary Strictures
    Kalakonda, Aditya
    Mayigegowda, Kavya Kelagere
    Desilets, David J.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2020, 115 : S34 - S35
  • [8] Systematic review and meta-analysis of percutaneous transluminal forceps biopsy for diagnosing malignant biliary strictures
    Jeon, Tae Yeon
    Choi, Moon Hyung
    Yoon, Seung Bae
    Soh, Jae Seung
    Moon, Sung-Hoon
    EUROPEAN RADIOLOGY, 2022, 32 (03) : 1747 - 1756
  • [9] Systematic review and meta-analysis of percutaneous transluminal forceps biopsy for diagnosing malignant biliary strictures
    Tae Yeon Jeon
    Moon Hyung Choi
    Seung Bae Yoon
    Jae Seung Soh
    Sung-Hoon Moon
    European Radiology, 2022, 32 : 1747 - 1756
  • [10] PERCUTANEOUS TRANSLUMINAL BIOPSY OF BILIARY STRICTURES WITH A BIOPTOME
    TERASAKI, K
    WITTICH, GR
    LYCKE, G
    WALTER, R
    NOWELS, K
    SWANSON, D
    LUCAS, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (01) : 77 - 78