Incremental value of multiplex real-time PCR for the early diagnosis of sepsis in the emergency department

被引:11
|
作者
Schaub, Nora [1 ]
Boldanova, Tujana [1 ]
Noveanu, Markus [1 ]
Arenja, Nisha [1 ]
Hermann, Heinz [2 ]
Twerenbold, Raphael [1 ]
Frei, Reno [3 ]
Bingisser, Roland [4 ]
Trampuz, Andrej [2 ,5 ]
Mueller, Christian [1 ]
机构
[1] Univ Basel Hosp, Dept Internal Med, CH-4031 Basel, Switzerland
[2] Univ Basel Hosp, Infect Dis Res Lab, Dept Biomed, CH-4031 Basel, Switzerland
[3] Univ Basel Hosp, Microbiol Lab, CH-4031 Basel, Switzerland
[4] Univ Basel Hosp, Emergency Dept, CH-4031 Basel, Switzerland
[5] Charite Univ Med Berlin, Ctr Musculoskeletal Surg, Berlin, Germany
基金
瑞士国家科学基金会;
关键词
multiplex real-time PCR; sepsis; emergency department; POLYMERASE-CHAIN-REACTION; RAPID DETECTION; BLOOD CULTURE; UNITED-STATES; EPIDEMIOLOGY; BACTEREMIA; INFECTION; BACTERIAL; THERAPY; ASSAY;
D O I
10.4414/smw.2014.13911
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Delayed recognition of sepsis and inappropriate initial antibiotic therapy are associated with increased mortality and morbidity. The early detection of the causative organism in sepsis is an unmet clinical need. A novel multiplex real-time polymerase chain reaction (MRT-PCR) (SeptiFast (R)) technique may provide the microbiological diagnosis within six hours. METHODS: We assessed the diagnostic accuracy of blood cultures and MRT-PCR in a comparative diagnostic cohort study in 110 consecutive adult patients presenting to the emergency department (ED) with suspected sepsis. RESULTS: We collected 205 corresponding PCR samples and blood culture (BC) pairs from the 110 patients. There was moderate to high concordance between PCR and BC with 181 (88%) matching and 24 (12%) mismatching samples. The diagnostic accuracy of MRT-PCR in detecting sepsis and its causative organism was comparable to that of BCs. The additional use of MRT-PCR significantly reduced the time to microbiological diagnosis as compared to the use of conventional microbiological methods alone (mean time gained 3.9 hours, range 0-66 hours, p < 0.001). CONCLUSION: Diagnostic accuracy of BCs and MRT-PCR in the early diagnosis of sepsis and its causative organism in the ED are comparable. However, MRT-PCR reduces the time to microbiological diagnosis. Whether a more rapid detection of the organism by MRT-PCR could improve the outcome of patients has to be assessed in large prospective randomised trials.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Rapid diagnosis of sepsis with TaqMan-Based multiplex real-time PCR
    Liu, Chang-Feng
    Shi, Xin-Ping
    Chen, Yun
    Jin, Ye
    Zhang, Bing
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (02)
  • [2] Comparison of blood culture and multiplex real-time PCR for the diagnosis of nosocomial sepsis
    Dinc, Fatih
    Akalin, Halis
    Ozakin, Cuneyt
    Sinirtas, Melda
    Kebabci, Nesrin
    Iscimen, Remzi
    Kelebek Girgin, Nermin
    Kahveci, Ferda
    [J]. MINERVA ANESTESIOLOGICA, 2016, 82 (03) : 301 - 309
  • [3] Assessing the value of a real-time electronic screening algorithm for early detection of severe sepsis in the emergency department
    P Martin-Rico
    A Valdivia-Perez
    JM Lacalle-Martinez
    J Chorda-Ribelles
    MD Marco-Lattur
    N Lozano-Cortell
    M Jordan-Lluch
    E Mateo-Sanchis
    R Andres-Navarro
    P Olcina-Lloret
    JD Garcia-Pedro
    O Esparcias-Rodriguez
    J Magraner-Egea
    A Barcelo-Lopez
    [J]. Critical Care, 18 (Suppl 2):
  • [4] Laboratory diagnosis of late-onset sepsis in newborns by multiplex real-time PCR
    Paolucci, Michela
    Capretti, Maria Grazia
    Dal Monte, Paola
    Corvaglia, Luigi
    Landini, Maria Paola
    Varani, Stefania
    Pession, Andrea
    Faldella, Giacomo
    Sambri, Vittorio
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2009, 58 (04) : 533 - 534
  • [5] Real-time multiplex PCR for the diagnosis of syphilis and chancroid
    Alexander, S
    Cole, M
    Martin, I
    Gundugola, K
    Bignell, CJ
    Ison, C
    [J]. SEXUALLY TRANSMITTED INFECTIONS, 2006, 82 : A2 - A3
  • [6] Development of a multiplex real-time PCR assay for the rapid diagnosis of neonatal late onset sepsis
    van den Brand, Marre
    Peters, Remco P. H.
    Catsburg, Arnold
    Rubenjan, Anna
    Broeke, Ferdi J.
    van den Dungen, Frank A. M.
    van Weissenbruch, Mirjam M.
    van Furth, A. Marceline
    Koressaar, Triinu
    Remm, Maido
    Savelkoul, Paul H. M.
    Bos, Martine P.
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2014, 106 : 8 - 15
  • [7] The clinical impact of a multiplex real-time PCR system for microbiological diagnosis of sepsis: a mortality study
    Grijalva, Marcelo
    De La Torre, Katherine
    Sanchez, Nataly
    [J]. NEW MICROBIOLOGICA, 2020, 43 (02): : 64 - 69
  • [8] Real-time multiplex PCR for human echinococcosis and differential diagnosis
    Knapp, Jenny
    Lallemand, Severine
    Monnien, Franck
    Felix, Sophie
    Courquet, Sandra
    Umhang, Gerald
    Millon, Laurence
    [J]. PARASITE, 2023, 30
  • [9] Multiplex real-time PCR for the diagnosis of malaria: correlation with microscopy
    Dormond, L.
    Jaton-Ogay, K.
    de Valliere, S.
    Genton, B.
    Bille, J.
    Greub, G.
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2011, 17 (03) : 469 - 475
  • [10] Utility of multiplex real-time PCR in the diagnosis of extrapulmonary tuberculosis
    Raveendran, Reena
    Wattal, Chand
    [J]. BRAZILIAN JOURNAL OF INFECTIOUS DISEASES, 2016, 20 (03): : 235 - 241