Association of secondary displacement of distal radius fractures with cortical bone quality at the distal radius

被引:6
|
作者
Daniels, A. M. [1 ,2 ]
Janzing, H. M. J. [1 ]
Wyers, C. E. [2 ,3 ,4 ]
van Rietbergen, B. [5 ,6 ]
Vranken, L. [2 ,3 ]
Van der Velde, R. Y. [2 ,3 ]
Geusens, P. . P. M. M. [4 ,7 ]
Kaarsemaker, S. [8 ]
Poeze, M. [2 ,9 ]
Van den Bergh, J. P. [2 ,3 ,4 ,7 ]
机构
[1] VieCuri Med Ctr, Dept Surg, Tegelseweg 210, NL-5912 BL Venlo, Netherlands
[2] Maastricht Univ, NUTRIM Sch Nutr & Translat Res Metab, Univ Singel 40, NL-6229 ER Maastricht, Netherlands
[3] VieCuri Med Ctr, Dept Internal Med, Subdiv Endocrinol, Tegelseweg 210, NL-5912 BL Venlo, Netherlands
[4] Maastricht Univ, Dept Internal Med, Med Ctr, P Debyelaan 25, NL-6229 HX Maastricht, Netherlands
[5] Eindhoven Univ Technol, Dept Biomed Engn, Orthopaed Biomech, De Rondom 70, NL-5612 AP Eindhoven, Netherlands
[6] Maastricht Univ, Dept Orthopaed Surg, Res Sch CAPHRI, Univ Singel 40, NL-6229 ER Maastricht, Netherlands
[7] Hasselt Univ, Fac Med, Martelarenlaan 42, B-3500 Hasselt, Belgium
[8] VieCuri Med Ctr, Dept Orthopaed Surg, Tegelseweg 210, NL-5912 BL Venlo, Netherlands
[9] Maastricht Univ, Dept Surg, Subdiv Traumatol, Med Ctr, P Debyelaan 25, NL-6229 HX Maastricht, Netherlands
关键词
Distal radius fracture (DRF); Fracture displacement; High-resolution peripheral quantitative CT (HR-pQCT); Bone microarchitecture and strength; Primary reduction; CLASSIFICATION SYSTEMS; CLOSED REDUCTION; MINERAL DENSITY; PREDICTION; INSTABILITY; AO; COMPLICATIONS; RELIABILITY; STABILITY; IMPACT;
D O I
10.1007/s00402-020-03658-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction The aim of this study was to investigate the associations of patient characteristics, bone mineral density (BMD), bone microarchitecture and calculated bone strength with secondary displacement of a DRF based on radiographic alignment parameters. Materials and methods Dorsal angulation, radial inclination and ulnar variance were assessed on conventional radiographs of a cohort of 251 patients, 38 men and 213 women, to determine the anatomic position of the DRF at presentation (primary position) and during follow-up. Secondary fracture displacement was assessed in the non-operatively treated patients (N = 154) with an acceptable position, preceded (N = 97) or not preceded (N = 57) by primary reduction (baseline position). Additionally, bone microarchitecture and calculated bone strength at the contralateral distal radius and tibia were assessed by HR-pQCT in a subset of, respectively, 63 and 71 patients. Outcome Characteristics of patients with and without secondary fracture displacement did not differ. In the model with adjustment for primary reduction [OR 22.00 (2.27-212.86), p = 0.008], total [OR 0.16 (95% CI 0.04-0.68), p = 0.013] and cortical [OR 0.19 (95% CI 0.05-0.80], p = 0.024] volumetric BMD (vBMD) and cortical thickness [OR 0.13 (95% CI 0.02-0.74), p = 0.021] at the distal radius were associated with secondary DRF displacement. No associations were found for other patient characteristics, such as age gender, BMD or prevalent vertebral fractures. Conclusions In conclusion, our study indicates that besides primary reduction, cortical bone quality may be important for the risk of secondary displacement of DRFs.
引用
收藏
页码:1909 / 1918
页数:10
相关论文
共 50 条
  • [1] Association of secondary displacement of distal radius fractures with cortical bone quality at the distal radius
    A. M. Daniels
    H. M. J. Janzing
    C. E. Wyers
    B. van Rietbergen
    L. Vranken
    R. Y. Van der Velde
    P . P. M. M. Geusens
    S. Kaarsemaker
    M. Poeze
    J. P. Van den Bergh
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1909 - 1918
  • [2] SECONDARY DISPLACEMENT OF REDUCED DISTAL RADIUS FRACTURES
    FENYO, G
    JOHANSSON, O
    ACTA ORTHOPAEDICA SCANDINAVICA, 1974, 45 (01): : 76 - 81
  • [3] COMMINUTED FRACTURES OF THE DISTAL RADIUS BONE
    GITARD, R
    LAGRANGE, M
    NOUVELLE PRESSE MEDICALE, 1982, 11 (47): : 3505 - 3506
  • [4] Assessment of articular displacement of distal radius fractures
    Catalano, LW
    Barron, OA
    Glickel, SZ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (423) : 79 - 84
  • [5] Secondary displacement of distal radius fractures treated by bridging external fixation
    Farah, N.
    Nassar, L.
    Farah, Z.
    Schuind, F.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2014, 39 (04) : 423 - 428
  • [6] Utiity of the Cortical Thickness of the Distal Radius as a Predictor of Distal-Radius Bone Density
    Rausch, Sascha
    Klos, Kajetan
    Gras, Florian
    Skulev, Elristo Kostov
    Popp, Albrecht
    Hofmann, Gunther Olaf
    Mueckly, Thomas
    ARCHIVES OF TRAUMA RESEARCH, 2013, 2 (01) : 11 - 15
  • [7] Distal radius fractures
    del Pinal, Francisco
    Jupiter, Jesse B.
    Rozental, Tamara D.
    Arora, Rohit
    Nakamura, Toshiyasu
    Bain, Gregory I.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2022, 47 (01) : 12 - 23
  • [8] Fractures of the distal Radius
    Konrads, Christian
    Gonser, Christoph
    Bahrs, Christian
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2021, 159 (02): : 217 - 231
  • [9] Distal radius fractures
    Herzberg, G.
    Burnier, M.
    HAND SURGERY & REHABILITATION, 2016, 35 : S1 - S2
  • [10] Fractures of the Distal Radius
    White, Jennifer
    ADVANCED EMERGENCY NURSING JOURNAL, 2013, 35 (01) : 8 - 15