A prospective, randomized trial comparing 25-gauge and 22-gauge needles for endoscopic ultrasound-guided fine needle aspiration of pancreatic masses

被引:49
|
作者
Lee, Jun Kyu [1 ]
Lee, Kyu Taek [2 ]
Choi, E. Ryoung [2 ]
Jang, Tae Hoon [2 ]
Jang, Kee-Taek [3 ]
Lee, Jong Kyun [2 ]
Lee, Kwang Hyuck [2 ]
机构
[1] Dongguk Univ, Ilsan Hosp, Dept Internal Med, Seoul, South Korea
[2] Sungkyunkwan Univ, Dept Med, Div Gastroenterol, Samsung Med Ctr,Sch Med, Seoul 135710, South Korea
[3] Sungkyunkwan Univ, Dept Pathol, Samsung Med Ctr, Sch Med, Seoul 135710, South Korea
关键词
22-gauge; 25-gauge; endoscopic ultrasound; fine needle aspiration; prospective trial; EUS-FNA; HEMOSUCCUS-PANCREATICUS; RETROSPECTIVE ANALYSIS; CYSTIC LESIONS; TRUCUT NEEDLE; DIAGNOSIS; COMPLICATIONS; FREQUENCY; 19-GAUGE; UTILITY;
D O I
10.3109/00365521.2013.786127
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives. Endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) is widely performed for pancreatic masses. The 25-gauge needle (25G) might be easier to be manipulated and expected to be associated with fewer complications since it is thinner and more flexible than the 22-gauge needle (22G) although obtaining adequate specimens is questioned. In this randomized trial, the authors tried to compare prospectively 25G and 22G in diagnostic accuracy, manipulability from the operator's viewpoint and procedure-related complications. Material and methods. A total of 188 consecutive patients undergoing EUS-FNA for solid or cystic pancreatic masses were consecutively enrolled and 94 patients were randomized to either 25G or 22G group, respectively. Results. Baseline characteristics were similar except that more masses of 25G group were located in the head or uncinate process of pancreas than those from 22G group. Although there was no difference in diagnostic accuracy (89.4% vs. 88.3% with p = 0.82), 25G was easier to be manipulated (p = 0.004) and related with fewer procedure-related complications (10.6% vs. 3.2% with p = 0.004). Conclusions. 25G can be chosen in preference to 22G when performing pancreatic EUS-FNA because 25G was significantly superior to 22G in terms of manipulability and complications although both were effective for accurate diagnosis.
引用
收藏
页码:752 / 757
页数:6
相关论文
共 50 条
  • [1] Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles
    Yang, Min Jae
    Yim, Hyunee
    Hwang, Jae Chul
    Lee, Dakeun
    Kim, Young Bae
    Lim, Sun Gyo
    Kim, Soon Sun
    Kang, Joon Koo
    Yoo, Byung Moo
    Kim, Jin Hong
    BMC GASTROENTEROLOGY, 2015, 15
  • [2] Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles
    Min Jae Yang
    Hyunee Yim
    Jae Chul Hwang
    Dakeun Lee
    Young Bae Kim
    Sun Gyo Lim
    Soon Sun Kim
    Joon Koo Kang
    Byung Moo Yoo
    Jin Hong Kim
    BMC Gastroenterology, 15
  • [3] ENDOSCOPIC ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION OF PANCREATIC LESIONS WITH 22-GAUGE VERSUS 25-GAUGE NEEDLES: A META-ANALYSIS OF RANDOMIZED TRIALS
    Facciorusso, A.
    Stasi, E.
    Di Maso, M.
    Serviddio, G.
    Del Prete, V.
    Muscatiello, N.
    DIGESTIVE AND LIVER DISEASE, 2017, 49 : E89 - E89
  • [4] Comparison of the 22-gauge and 25-gauge needles for endobronchial ultrasound-guided transbronchial needle aspiration
    Sakaguchi, Tadashi
    Inoue, Takeo
    Miyazawa, Teruomi
    Mineshita, Masamichi
    RESPIRATORY INVESTIGATION, 2021, 59 (02) : 235 - 239
  • [5] Blinded Prospective Comparison of the Performance of 22-Gauge and 25-Gauge Needles in Endoscopic Ultrasound-Guided Fine Needle Aspiration of the Pancreas and Peri-pancreatic Lesions
    Lee, Jeffrey H.
    Stewart, John
    Ross, William A.
    Anandasabapathy, Sharmila
    Xiao, Lianchun
    Staerkel, Gregg
    DIGESTIVE DISEASES AND SCIENCES, 2009, 54 (10) : 2274 - 2281
  • [6] Blinded Prospective Comparison of the Performance of 22-Gauge and 25-Gauge Needles in Endoscopic Ultrasound-Guided Fine Needle Aspiration of the Pancreas and Peri-pancreatic Lesions
    Jeffrey H. Lee
    John Stewart
    William A. Ross
    Sharmila Anandasabapathy
    Lianchun Xiao
    Gregg Staerkel
    Digestive Diseases and Sciences, 2009, 54 : 2274 - 2281
  • [7] EUS-guided FNA of solid pancreatic masses: a prospective, randomized trial comparing 22-gauge and 25-gauge needles
    Siddiqui, Uzma D.
    Rossi, Federico
    Rosenthal, Lawrence S.
    Padda, Manmeet S.
    Murali-Dharan, Visvanathan
    Aslanian, Harry R.
    GASTROINTESTINAL ENDOSCOPY, 2009, 70 (06) : 1093 - 1097
  • [8] Endoscopic Ultrasound-Guided Fine Needle Aspiration in Solid Pancreatic Tumors; A Prospective Randomized Comparison of 19-Gauge and 22-Gauge Aspiration Needles
    Song, Tae Jun
    Lee, Sang Soo
    Kim, Ji Hoon
    Park, Do Hyun
    Moon, Sung-Hoon
    Seo, Dong Wan
    Jang, Se Jin
    Lee, Sung Koo
    Kim, Myung-Hwan
    GASTROINTESTINAL ENDOSCOPY, 2009, 69 (05) : AB129 - AB129
  • [9] The diagnostic accuracy of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of solid pancreatic lesions: a meta-analysis
    Madhoun, M. F.
    Wani, S. B.
    Rastogi, A.
    Early, D.
    Gaddam, S.
    Tierney, W. M.
    Maple, J. T.
    ENDOSCOPY, 2013, 45 (02) : 86 - 92
  • [10] Endoscopic Ultrasound-Guided Fine Needle Aspiration of Pancreatic Masses in a Veteran Population Comparison of Results With 22- and 25-Gauge Needles
    Siddiqui, Ali A.
    Lyles, Thomas
    Avula, Harita
    Davila, Raquel
    PANCREAS, 2010, 39 (05) : 685 - 686