Plasma immersion ion implantation (PIII) influence on Ti-6Al-4V alloy: Frequency effect

被引:14
|
作者
Oliveira, V. M. C. A. [1 ]
Cioffi, M. O. H. [1 ]
Barboza, M. J. R. [2 ]
Landers, R. [3 ]
Schmitt, B. [4 ]
Tapia, D. C. A. R. [5 ]
Voorwald, H. J. C. [1 ]
机构
[1] Univ Estadual Paulista, Fac Engn Guaratingueta, Sao Paulo, Brazil
[2] Univ Sao Paulo, Escola Engn Lorena, Sao Paulo, Brazil
[3] Univ Estadual Campinas, Inst Fis Gleb Wataghin, Campinas, SP, Brazil
[4] Univ Bayreuth, Fac Engn Sci, Bayreuth, Germany
[5] Univ Nacl Ingn, Lima, Peru
基金
巴西圣保罗研究基金会;
关键词
Ti-6Al-4V alloy; PIII treatment; Frequency; Axial fatigue; AISI; 4340; STEEL; FATIGUE-STRENGTH; BENDING FATIGUE; STATISTICAL-ANALYSIS; CORROSION BEHAVIOR; TITANIUM-ALLOYS; TI6AL4V ALLOY; NITROGEN; TEMPERATURE; MICROSTRUCTURE;
D O I
10.1016/j.ijfatigue.2017.12.016
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The plasma immersion ion implantation treatment (PIII) acts to increase mechanical resistance with solid solution formation, new phases and defects inclusion, besides chemical and residual stress profile modification. Ti-6Al-4V alloy presents poor tribological properties and high affinity with interstitial elements, such as nitrogen and oxygen, this makes it more reactive at high temperatures. This paper aims to study Ti-6Al-4V alloy fatigue behavior subjected to nitrogen addition by plasma immersion ion implantation. It was investigated the frequency parameter influence on fatigue resistance. Ti-6Al-4V alloy was PIII treated with voltage equal to 9.5 kV, frequencies varying between 1000 and 1500 Hz and submitted to axial fatigue tests. Axial fatigue tests were performed, at room temperature and R = 0.1. Ti-6Al-4V alloy fatigue results were supported by Weibull statistics analysis. Ti-6Al-4V alloy microstructural analysis showed equiaxed alpha + beta grains. Weibull analysis at untreated condition presented m values greater than 1, indicating reliability and uniformity. For a lifetime of 10(7) cycles, fatigue resistance was equal to 829 MPa for untreated condition, 644, 767 and 417 MPa, for f = 1000, 1200 and 1500 Hz, respectively. The nitrogen-based compounds were detected only at the condition where f = 1200 Hz. Thus, the combination of PIII treatment parameters, when f = 1200 Hz, hindered crack nucleation and increasing fatigue resistance of treated Ti-6Al-4V alloy when compared with the other two treatment conditions.
引用
收藏
页码:157 / 165
页数:9
相关论文
共 50 条
  • [1] MICROSTRUCTURAL ANALYSIS OF TI-6AL-4V ALLOY AFTER PLASMA IMMERSION ION IMPLANTATION (PIII)
    Castagnet, M.
    Yogi, L. M.
    Silva, M. M.
    Ueda, M.
    Couto, A. A.
    Reis, D. A. P.
    Moura Neto, C.
    ADVANCED POWDER TECHNOLOGY VIII, PTS 1 AND 2, 2012, 727-728 : 50 - +
  • [2] Effect of plasma immersion ion implantation on wear behavior of Ti-6Al-4V alloy
    Resende, Fabricia Assis
    Silva, Maria Margareth
    Oliveira, Rogerio de Moares
    Silva, Carla
    Pichon, Luc
    Radi, Polyana Alves
    dos Reis, Adriano Goncalves
    Reis, Danieli Aparecida Pereira
    SURFACE TOPOGRAPHY-METROLOGY AND PROPERTIES, 2023, 11 (01)
  • [3] Radio-frequency plasma nitriding and nitrogen plasma immersion ion implantation of Ti-6Al-4V alloy
    Wang, SY
    Chu, PK
    Tang, BY
    Zeng, XC
    Chen, YB
    Wang, XF
    SURFACE & COATINGS TECHNOLOGY, 1997, 93 (2-3): : 309 - 313
  • [4] Fatigue behavior of Ti-6Al-4V alloy modified by plasma immersion ion implantation: temperature effect
    Velloso, Veronica
    Nozaki, Leonardo
    Tapia, Diego
    Cioffi, Maria Odila
    Oliveira, Rogerio
    Barboza, Miguel
    Voorwald, Herman
    12TH INTERNATIONAL FATIGUE CONGRESS (FATIGUE 2018), 2018, 165
  • [5] Effect of yttrium pre-implantation on implantation behavior of Ti-6Al-4V alloy in nitrogen plasma immersion ion implantation
    Wang, LP
    Tang, BY
    Wang, XF
    Wang, SY
    Paul, KC
    JOURNAL OF RARE EARTHS, 2001, 19 (01) : 40 - 43
  • [6] Effect of Yttrium Pre-Implantation on Implantation Behavior of Ti-6Al-4V Alloy in Nitrogen Plasma Immersion Ion Implantation
    王浪平
    唐保茵
    王小锋
    王松岩
    Journal of Rare Earths, 2001, (01) : 40 - 43
  • [7] Tribological effects of plasma immersion ion implantation heating treatments on Ti-6Al-4V alloy
    Mello, C. B.
    Ueda, M.
    Silva, M. M.
    Reuther, H.
    Pichon, L.
    Lepienski, C. M.
    WEAR, 2009, 267 (5-8) : 867 - 873
  • [8] Corrosion behavior of Ti-6Al-4V alloy treated by plasma immersion ion implantation process
    da Silva, L. L. G.
    Ueda, M.
    Silva, M. M.
    Codaro, E. N.
    SURFACE & COATINGS TECHNOLOGY, 2007, 201 (19-20): : 8136 - 8139
  • [9] Ion beam implantation and plasma immersion ion implantation. Application on nitrided Ti-6Al-4V titanium alloy
    Fabre, A
    Barrallier, L
    Torregrosa, F
    Roux, L
    MICROSCOPY MICROANALYSIS MICROSTRUCTURES, 1997, 8 (06): : 413 - 422
  • [10] Frictional Wear Resistance and Corrosion Resistance of Ag/Ti-6Al-4V Alloy System Treated by Plasma Immersion Ion Implantation Technique (PIII)
    Liu Hongxi
    Jiang Yehua
    Zhou Rong
    Zhan Zhaolin
    Yang Tianwu
    Tang Baoyin
    RARE METAL MATERIALS AND ENGINEERING, 2009, 38 (12) : 2126 - 2130