Test for arsenic speciation in waters based on a paper-based analytical device with scanometric detection

被引:49
|
作者
Pena-Pereira, Francisco [1 ]
Villar-Blanco, Lorena [1 ]
Lavilla, Isela [1 ]
Bendicho, Carlos [1 ]
机构
[1] Univ Vigo, Fac Chem, Analyt & Food Chem Dept, Campus As Lagoas Marcosende S-N, Vigo 36310, Spain
关键词
Paper-based analytical device; Arsenic speciation; Non-instrumental detection; Scanometric analysis; Water analysis; Screening; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; MICROFLUIDIC DEVICES; HYDRIDE GENERATION; CELLULOSE FIBERS; ANALYTICAL-CHEMISTRY; AQUEOUS SAMPLES; DRINKING-WATER; PRECONCENTRATION; NANOPARTICLES;
D O I
10.1016/j.aca.2018.01.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid, simple and affordable method for arsenic speciation analysis is described in this work. The proposed methodology involves in situ arsine generation, transfer of the volatile to the headspace and its reaction with silver nitrate at the detection zone of a paper-based analytical device (PAD). Thus, silver nitrate acts as a recognition element for arsine in the paper-based sensor. The chemical reaction between the recognition element and the analyte derivative results in the formation of a colored product which can be detected by scanning the detection zone and data treatment with an image processing and analysis program. Detection and injection zones were defined in the paper substrate by formation of hydrophobic barriers, thus enabling the formation of the volatile derivative without affecting the chemical stability of the recognition element present in the PAD. Experimental parameters influencing the analytical performance of the methodology, namely color mode detection, composition of the paper-based sensor and hydride generation and mass transfer conditions, were evaluated. Under optimal conditions, the proposed method showed limits of detection and quantification of 1.1 and 3.6 ng mL(-1), respectively. Remarkably, the limit of detection of the method reported herein was much lower than the maximum contaminant levels set by both the World Health Organization and the US Environmental Protection Agency for arsenic in drinking water, unlike several commercially available arsenic test kits. The repeatability, expressed as relative standard deviation, was found to be 7.1% (n = 8). The method was validated against the European Reference Material ERM (R)-CA615 groundwater and successfully applied to the determination of As(III), As(V) and total inorganic As in different water samples. Furthermore, the method can be used for the screening analysis of total arsenic in waters when a cut-off level of 7 ng mL(-1) is used. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [1] Colorimetric Paper-Based Analytical Device for Perfluorooctanesulfonate Detection
    Menger, Ruth F.
    Beck, Josianne J.
    Borch, Thomas
    Henry, Charles S.
    ACS ES&T WATER, 2022, 2 (04): : 565 - 572
  • [2] Microfluidic paper-based analytical device for the speciation of inorganic nitrogen species
    Uhlikova, Natalie
    Almeida, M. Ines G. S.
    Mckelvie, Ian D.
    Kolev, Spas D.
    TALANTA, 2024, 271
  • [3] Paper-based scanometric assay for lead ion detection using DNAzyme
    Vijitvarasan, Pasara
    Oaew, Sukunya
    Surareungchai, Werasak
    ANALYTICA CHIMICA ACTA, 2015, 896 : 152 - 159
  • [4] Speciation of inorganic arsenic in aqueous samples using a novel hydride generation microfluidic paper-based analytical device (μPAD)
    Bonacci, Mason E.
    Almeida, M. Ines G. S.
    Zhang, Yanlin
    Kolev, Spas D.
    MICROCHIMICA ACTA, 2022, 189 (07)
  • [5] Speciation of inorganic arsenic in aqueous samples using a novel hydride generation microfluidic paper-based analytical device (µPAD)
    Mason E. Bonacci
    M. Inês G. S. Almeida
    Yanlin Zhang
    Spas D. Kolev
    Microchimica Acta, 2022, 189
  • [6] Aptasensor platform based on electrochemical Paper-Based analytical device for histamine detection
    Eksin, Ece
    Erdem, Arzum
    MICROCHEMICAL JOURNAL, 2024, 204
  • [7] Ultrasensitive chemiluminescence detection of DNA on a microfluidic paper-based analytical device
    Yanhu Wang
    Shoumei Wang
    Shenguang Ge
    Shaowei Wang
    Mei Yan
    Dejin Zang
    Jinghua Yu
    Monatshefte für Chemie - Chemical Monthly, 2014, 145 : 129 - 135
  • [8] Ultrasensitive chemiluminescence detection of DNA on a microfluidic paper-based analytical device
    Wang, Yanhu
    Wang, Shoumei
    Ge, Shenguang
    Wang, Shaowei
    Yan, Mei
    Zang, Dejin
    Yu, Jinghua
    MONATSHEFTE FUR CHEMIE, 2014, 145 (01): : 129 - 135
  • [9] Fast and sensitive screening detection of tetracyclines with a paper-based analytical device
    Zhou, Ting
    Liu, Jia-Juan
    Xu, Ye
    Wu, Zhi-Yong
    MICROCHEMICAL JOURNAL, 2019, 145 : 703 - 707
  • [10] Paper-Based Analytical Device for the On-Site Detection of Nerve Agents
    Yamaguchi, Akinori
    Miyaguchi, Hajime
    Ishida, Akihiko
    Tokeshi, Manabu
    ACS APPLIED BIO MATERIALS, 2021, 4 (08): : 6512 - 6518