Problems with Rayleigh Damping in Base-Isolated Buildings

被引:106
|
作者
Ryan, Keri L. [1 ]
Polanco, Jose [2 ]
机构
[1] Utah State Univ, Dept Civil & Environm Engn, Logan, UT 84322 USA
[2] JCI Engn, Las Vegas, NV 89117 USA
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 2008年 / 134卷 / 11期
关键词
Base isolation; Damping; Numerical models;
D O I
10.1061/(ASCE)0733-9445(2008)134:11(1780)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In dynamic analysis, the energy dissipation in a base-isolated building is typically accounted for by allocating damping properties independently to the superstructure and to the isolation system. Rayleigh damping applied to the superstructure component alone is often used to represent the superstructure energy dissipation. At least one study has indicated that when used improperly, superstructure Rayleigh damping leads to excessive damping of the response of a base-isolated structure. As shown here, even when used as recommended for combining subsystems with disparate damping properties, Rayleigh damping results in undesirable suppression of the first mode response. To correct this behavior, stiffness-proportional damping can be used in lieu of Rayleigh damping. Stiffness-proportional damping is demonstrated to negligibly affect the first mode response, yet provide the expected energy dissipation in higher modes.
引用
收藏
页码:1780 / 1784
页数:5
相关论文
共 50 条
  • [1] A distributed flexibility and damping strategy to control vertical accelerations in base-isolated buildings
    Vu, Bach
    Unal, Mehmet
    Warn, Gordon P.
    Memari, Ali M.
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2014, 21 (04): : 503 - 521
  • [2] ASSESSMENT OF BASE-ISOLATED BUILDINGS DESIGNED USING INTERNATIONAL DAMPING MODIFICATION FACTORS
    Mansour, Mohamed Hesham
    Hussein, Mahar Maher
    Akl, Adel Yehia
    [J]. INTERNATIONAL JOURNAL OF GEOMATE, 2021, 21 (83): : 1 - 10
  • [4] QUAKE TESTS BASE-ISOLATED BUILDINGS
    不详
    [J]. CIVIL ENGINEERING, 1988, 58 (04): : 19 - 19
  • [5] Damping-adjusted combination rule for the response spectrum analysis of base-isolated buildings
    Muscolino, Giuseppe
    Palmeri, Alessandro
    Versaci, Claudia
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2013, 42 (02): : 163 - 182
  • [6] Dynamics of seismic impacts in base-isolated buildings
    Malhotra, PK
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1997, 26 (08): : 797 - 813
  • [7] Wind effects on habitability of base-isolated buildings
    Bo, L
    Xiong, SS
    Tang, JX
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2002, 90 (12-15) : 1951 - 1958
  • [8] Seismic Response Mitigation of Base-Isolated Buildings
    Stanikzai, Mohammad Hamayoun
    Elias, Said
    Rupakhety, Rajesh
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (04):
  • [9] RESPONSE OF BASE-ISOLATED BUILDINGS TO WIND LOADING
    HENDERSON, P
    NOVAK, M
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1989, 18 (08): : 1201 - 1217
  • [10] Research on the simplified calculation of base-isolated buildings
    Liu, Lijun
    Zhao, Xindong
    Wang, Sheliang
    [J]. Jianzhu Jiegou Xuebao/Journal of Building Structures, 2006, 27 (SUPPL.): : 625 - 627