Gafchromic EBT2 dosimetry via robust optimization

被引:5
|
作者
Alves, Victor G. L. [1 ,2 ,3 ]
Cardoso, Simone C. [2 ]
da Silva, Ademir X. [1 ]
机构
[1] Univ Fed Rio de Janeiro, Ilha Fundao, PEN COPPE DNC EE, BR-21945970 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Rio de Janeiro, Ilha Fundao, Inst Fis, Lab Fis Radiacao Gama, BR-21941972 Rio De Janeiro, RJ, Brazil
[3] Inst Nacl Canc, Serv Qualidade Radiacoes Ionizantes, BR-20231092 Rio De Janeiro, RJ, Brazil
关键词
Radiotherapy; Dosimetry; Radiochromic film; Robust optimization; IMRT; RADIOCHROMIC FILM DOSIMETRY;
D O I
10.1016/j.cpc.2013.02.023
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
An 'in house' software was developed with MATLAB in order to perform optimized dose calculations in radiotherapy. The aim of this work is to demonstrate an improvement on the Multichannel method using robust optimization that deals with optimization problems where robustness is sought against uncertainty. An optimization framework was developed in order to compare remaining error from optimization process of robust methods against the conventional triple-channel method. The proposed robust method minimizes the dose difference over all channels compared to the original triple-channel method, mainly over clinical dose range. Even if a Gafchromic EBT2 film irradiated by composite IMRT fields is analyzed, more consistent values than the ones obtained by the triple-channel method are found and Newton Rings patterns are minimized. When robust methods are applied, the difference between blue and red channel doses was found to be very small, about 104 times less than obtained by triple-channel optimization. It is well known that one outlier may cause a large error in a least squares estimator. The blue channel correction of non-uniformities may have best performance when robust optimization is used. A variety of anomalies (artifacts, Newton rings and other disturbances) behave differently from natural Gaussian random noise such as variations of the thickness. The use of robust optimization methods might be more realistic since this approach uses fatter tail distributions as the Laplace and could mitigate the Newton's Rings Pattern. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1708 / 1716
页数:9
相关论文
共 50 条
  • [1] Evaluation of the Gafchromic® EBT2 film for the dosimetry of radiosurgical beams
    Larraga-Gutierrez, Jose M.
    Garcia-Hernandez, Diana
    Garcia-Garduno, Olivia A.
    Galvan de la Cruz, Olga O.
    Ballesteros-Zebadua, Paola
    Esparza-Moreno, Karina P.
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 6111 - 6117
  • [2] Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry
    Moylan, Rebecca
    Aland, Trent
    Kairn, Tanya
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (03) : 331 - 337
  • [3] Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry
    Rebecca Moylan
    Trent Aland
    Tanya Kairn
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 331 - 337
  • [4] Comparison of the radio chromatic EBT film Dosimetry with EBT2 (Gafchromic) for IMRT Verification
    Schwedas, M.
    Howitz, S.
    Wiezorek, T.
    Wendt, T. G.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 105 - 105
  • [5] IN VIVO DOSIMETRY BY EBT2 GAFCHROMIC FILMS TO VALIDATE A IORT PROCEDURE
    Magi, S.
    Romagnoli, R.
    Palombarini, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S12 - S12
  • [6] Spectrometric studies of the Gafchromic EBT2
    Bodmann, B.
    Petersen, C.
    Cremers, F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 104 - 104
  • [7] Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance
    Aland, T.
    Kairn, T.
    Kenny, J.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (02) : 251 - 260
  • [8] Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance
    T. Aland
    T. Kairn
    J. Kenny
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2011, 34 : 251 - 260
  • [9] Neutron response of GafChromic® EBT2 film
    Hsiao, Ming-Chen
    Liu, Yuan-Hao
    Chen, Wei-Lin
    Jiang, Shiang-Huei
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (05): : 1391 - 1413
  • [10] High dose per fraction dosimetry of small fields with Gafchromic EBT2 film
    Hardcastle, Nicholas
    Basavatia, Amar
    Bayliss, Adam
    Tome, Wolfgang A.
    [J]. MEDICAL PHYSICS, 2011, 38 (07) : 4081 - 4085