Accuracy and consequences of 3D-fluoroscopy in upper and lower extremity fracture treatment: A systematic review

被引:22
|
作者
Beerekamp, M. S. H. [1 ]
Sulkers, George S. I. [1 ]
Ubbink, Dirk T. [2 ]
Maas, Mario [3 ]
Schep, Niels W. L. [1 ]
Goslings, J. Carel [1 ]
机构
[1] Acad Med Ctr, Dept Surg, Trauma Unit, NL-1100 DD Amsterdam, Netherlands
[2] Acad Med Ctr, Dept Qual & Proc Innovat, NL-1100 DD Amsterdam, Netherlands
[3] Acad Med Ctr, Dept Radiol, NL-1100 DD Amsterdam, Netherlands
关键词
Fracture; Intra-operative; Imaging; 2D-fluoroscopy; 3D-fluoroscopy; CT; MOBILE C-ARM; INTRAOPERATIVE REDUCTION; IMAGE INTENSIFIER; 3-DIMENSIONAL CT; ISO-C-3D; QUALITY; FIXATION; ANKLE;
D O I
10.1016/j.ejrad.2012.06.021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this systematic review was to compare the diagnostic accuracy, subjective image quality and clinical consequences of 3D-fluoroscopy with standard imaging modalities (2D-fluoroscopy, X-ray or CT) during reduction and fixation of intra-articular upper and lower extremity fractures. Methods: A systematic literature search was performed in MEDLINE, EMBASE and the Cochrane library. In total 673 articles were identified (up to March 2012). The 19 included studies described patients/cadavers with intra-articular upper/lower extremity fractures and compared 3D-fluoroscopy to standard imaging. The study was performed in accordance with the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) guidelines. Diagnostic accuracy was defined by the quality of fracture reduction or implant position and, if possible, expressed as sensitivity and specificity; subjective image quality was determined by the quality of depiction of bone or implants; clinical consequences were defined as corrections in reduction or implant position following 3D-fluoroscopy. Results: Ten cadaver-and nine clinical studies were included. A meta-analysis was not possible, because studies used different scoring protocols to express diagnostic accuracy and reported incomplete data. Based on the individual studies, diagnostic accuracy of 3D-fluoroscopy was better than 2D-fluoroscopy and X-ray, but similar to CT-scanning. Subjective image quality of 3D-fluoroscopy was inferior compared to all other imaging modalities. In 11-40% of the operations additional corrections were performed after 3D-fluoroscopy, while the necessity for these corrections were not recognized based on 2D-fluoroscopic images. Conclusions: Although subjective image quality is rated inferior compared to other imaging modalities, intra-operative use of 3D-fluoroscopy is a helpful diagnostic tool for improving the quality of reduction and implant position in intra-articular fractures. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:4019 / 4028
页数:10
相关论文
共 50 条
  • [1] Intraoperative 3D-Fluoroscopy Increases Accuracy of Syndesmotic Reduction in Ankle Fractures with Syndesmotic Instability
    Duschek, S.
    Leucht, A. K.
    Aregger, F.
    Meier, C.
    BRITISH JOURNAL OF SURGERY, 2023, 110 (SUPP 5)
  • [2] Intraoperative 3D-fluoroscopy increases accuracy of syndesmotic reduction in ankle fractures with syndesmotic instability
    Duschek, Silvia
    Leucht, Anna-Kathrin
    Aregger, Fintan
    Meier, Christoph
    SWISS MEDICAL WEEKLY, 2023, 153 : 55S - 55S
  • [3] Chiropractic treatment of upper extremity conditions: A systematic review
    McHardy, Andrew
    Hoskins, Wayne
    Pollard, Henry
    Onley, Rorey
    Windsham, Ross
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2008, 31 (02) : 146 - 159
  • [4] Utilization of 3D printed orthoses for musculoskeletal conditions of the upper extremity: A systematic review
    Schwartz, Deborah A.
    Schofield, Katherine A.
    JOURNAL OF HAND THERAPY, 2023, 36 (01) : 166 - 178
  • [5] Surgical Treatment and Rehabilitation Strategies for Upper and Lower Extremity Lymphedema: A Comprehensive Review
    de Sire, Alessandro
    Losco, Luigi
    Lippi, Lorenzo
    Spadoni, Davide
    Kaciulyte, Juste
    Sert, Gokhan
    Ciamarra, Paola
    Marcasciano, Marco
    Cuomo, Roberto
    Bolletta, Alberto
    Invernizzi, Marco
    Cigna, Emanuele
    MEDICINA-LITHUANIA, 2022, 58 (07):
  • [6] Precision and accuracy of 3D lower extremity residua measurement systems
    Commean, PK
    Smith, KE
    Vannier, MW
    Hildebolt, CF
    Pilgram, TK
    MEDICAL IMAGING 1996: IMAGE PROCESSING, 1996, 2710 : 494 - 510
  • [7] Diagnostic accuracy of ultrasound for upper extremity fractures in children: A systematic review and meta-analysis*
    Tsou, Po-Yang
    Ma, Yu-Kun
    Wang, Yu-Hsun
    Gillon, Jason T.
    Rafael, John
    Deanehan, Julia K.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 44 : 383 - 394
  • [8] Accuracy of diagnostic tests for clinically suspected upper extremity deep vein thrombosis: a systematic review
    Di Nisio, M.
    van Sluis, G. L.
    Bossuyt, P. M. M.
    Buller, H. R.
    Porreca, E.
    Rutjes, A. W. S.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2010, 8 (04) : 684 - 692
  • [9] Intermittent pneumatic compression for the treatment of lower extremity arterial disease: a systematic review
    Labropoulos, N
    Wierks, C
    Suffoletto, B
    VASCULAR MEDICINE, 2002, 7 (02) : 141 - 148
  • [10] Reliability of the Clinical Measurement of Upper and Lower Extremity Joint Motion in the Pediatric Population: A Systematic Review
    Sala, Debra A.
    Ragni, Lori B.
    PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2024, 44 (02) : 248 - 276