Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: comparison with four other dynamic indices

被引:102
|
作者
Monnet, X. [2 ,3 ]
Dres, M. [2 ,3 ]
Ferre, A. [2 ,3 ]
Le Teuff, G. [4 ]
Jozwiak, M. [2 ,3 ]
Bleibtreu, A. [2 ,3 ]
Le Deley, M-C [4 ]
Chemla, D. [1 ,3 ]
Richard, C. [2 ,3 ]
Teboul, J-L [2 ,3 ]
机构
[1] Hop Univ Paris Sud, Hop Antoine Beclere, AP HP, Serv Physiol, Paris, France
[2] Hop Univ Paris Sud, Hop Bicetre, AP HP, Serv Reanimat Med, Paris, France
[3] Univ Paris 11, EA4533, Orsay, France
[4] Inst Gustave Roussy, Unite Biostat & Epidemiol, Villejuif, France
关键词
arterial pressure; measurement; equipment; Finapress; monitors; fluid therapy; measurement techniques; shock; END-EXPIRATORY OCCLUSION; STROKE VOLUME VARIATION; PULSE PRESSURE; RESPIRATORY CHANGES; PRECISION; ACCURACY;
D O I
10.1093/bja/aes182
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We evaluated the ability of an infrared photoplethysmography arterial waveform (continuous non-invasive arterial pressure, CNAP) to estimate arterial pulse pressure variation (PPV). We compared the ability of non-invasive PPV to predict fluid responsiveness with invasive PPV, respiratory variation of pulse contour-derived stroke volume, and changes in cardiac index induced by passive leg raising (PLR) and end-expiratory occlusion (EEO) tests. We measured the responses of cardiac index (PiCCO) to 500 ml of saline in 47 critically ill patients with haemodynamic failure. Before fluid administration, we recorded non-invasive and invasive PPVs, stroke volume variation, and changes in cardiac index induced by PLR and by 15 s EEO. Logistic regressions were performed to investigate the advantage of combining invasive PPV, stroke volume variation, PLR, and EEO when predicting fluid responsiveness. In eight patients, CNAP could not record arterial pressure. In the 39 remaining patients, fluid increased cardiac index by epsilon 15 in 17 oresponders'. Considering the 195 pairs of measurements, the bias (sd) between invasive and non-invasive PPVs was 0.6 (2.3). The areas under the receiver operating characteristic (ROC) curves for predicting fluid responsiveness were 0.89 (95 confidence interval, 0.781.01) for non-invasive PPV compared with 0.89 (0.771.01), 0.84 (0.700.96), 0.95 (0.881.03), and 0.97 (0.911.03) for invasive pulse pressure, stroke volume variations, PLR, and EEO tests (no significant difference). Combining multiple tests did not significantly improve the area under the ROC curves. Non-invasive assessment of PPV seems valuable in predicting fluid responsiveness.
引用
收藏
页码:330 / 338
页数:9
相关论文
共 50 条
  • [1] PREDICTION OF FLUID RESPONSIVENESS BY A NON INVASIVE ASSESSMENT OF ARTERIAL PRESSURE IN SEPTIC SHOCK: COMPARISON WITH FIVE OTHER DYNAMIC INDICES
    Monnet, X.
    Dres, M.
    Ferre, A.
    Bleibtreu, A.
    Richard, C.
    Teboul, J. -L.
    INTENSIVE CARE MEDICINE, 2009, 35 : 78 - 78
  • [2] Arterial blood pressure monitoring in overweight critically ill patients: Invasive or non-invasive?
    Bander, JJ
    Guzman, JA
    Araghi, A
    CHEST, 2004, 126 (04) : 746S - 747S
  • [3] Non-invasive continuous arterial pressure monitoring with Nexfin does not sufficiently replace invasive measurements in critically ill patients
    Hohn, A.
    Defosse, J. M.
    Becker, S.
    Steffen, C.
    Wappler, F.
    Sakka, S. G.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (02) : 178 - 184
  • [4] Non-invasive assessment of the microcirculation in critically ill patients
    Nanas, S.
    Gerovasili, V.
    Renieris, P.
    Angelopoulos, E.
    Poriazi, M.
    Kritikos, K.
    Siafaka, A.
    Baraboutis, I.
    Zervakis, D.
    Markaki, V.
    Routsi, C.
    Roussos, C.
    ANAESTHESIA AND INTENSIVE CARE, 2009, 37 (05) : 733 - 739
  • [5] Interest of clinical assessment in prediction of fluid responsiveness in critically ill patients
    Savry, C
    Neirynck, C
    Dy, L
    Prat, G
    Quinio, P
    INTENSIVE CARE MEDICINE, 2002, 28 : S7 - S7
  • [6] Comparison of Non-invasive and Invasive Arterial Blood Pressure Measurement for Assessment of Dynamic Cerebral Autoregulation
    Nils H. Petersen
    Santiago Ortega-Gutierrez
    Andres Reccius
    Arjun Masurkar
    Amy Huang
    Randolph S. Marshall
    Neurocritical Care, 2014, 20 : 60 - 68
  • [7] Comparison of Non-invasive and Invasive Arterial Blood Pressure Measurement for Assessment of Dynamic Cerebral Autoregulation
    Petersen, Nils H.
    Ortega-Gutierrez, Santiago
    Reccius, Andres
    Masurkar, Arjun
    Huang, Amy
    Marshall, Randolph S.
    NEUROCRITICAL CARE, 2014, 20 (01) : 60 - 68
  • [8] Non-invasive cardiac output assessment in critically ill paediatric patients
    Wongsirimetheekul, Theeranan
    Khositseth, Anant
    Lertbunrian, Rojjanee
    ACTA CARDIOLOGICA, 2014, 69 (02) : 167 - 173
  • [9] Validation study of Nexfin® continuous non-invasive blood pressure monitoring in critically ill adult patients
    Ameloot, K.
    Van de Vijver, K.
    Van Regenmortel, N.
    De Laet, I.
    Schoonheydt, K.
    Dits, H.
    Broch, O.
    Bein, B.
    Malbrain, M. L. N. G.
    MINERVA ANESTESIOLOGICA, 2014, 80 (12) : 1294 - 1301
  • [10] Feasibility study of continuous non-invasive blood pressure measurement in critically ill children
    C Hofhuizen
    J Lemson
    L van de Sant
    O Schraa
    J Settels
    J van der Hoeven
    Critical Care, 10 (Suppl 1):