Speckle-tracking analysis based on 2D echocardiography does not reliably measure left ventricular torsion

被引:13
|
作者
Parisi, Valentina [1 ]
Losi, Maria Angela [1 ]
Contaldi, Carla [1 ]
Chiacchio, Elena [1 ]
Pastore, Fabio [1 ]
Scatteia, Alessandra [1 ]
Giamundo, Alessandra [1 ]
di Nardo, Carlo [1 ]
Lombardi, Raffaella [1 ]
Betocchi, Sandro [1 ]
机构
[1] Univ Naples Federico II, Dept Clin Med Cardiovasc & Immunol Sci, I-80131 Naples, Italy
关键词
echocardiography; left ventricular function; speckle tracking; twist; TWIST; DEFORMATION;
D O I
10.1111/cpf.12002
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose Worldwide left ventricular (LV) twist is measured by 2D speckle tracking acquiring apical short axis at a LV level where papillary muscles are no longer visible; however, we hypothesized that this methodological recommendation is not enough accurate to obtain a reliable measurement of apical rotation. Methods We measured twist and untwist rate in 30 healthy subjects by following the earlier method. By 3D echocardiography, we identified two LV apex levels: (i) 3D Apex, defined as the last apical slice at which LV cavity was visible; (ii) 2D Apex, defined as the level where diameters are equal to those of apical LV short axis used for twist analysis in the same subject. The ratio between the distance of 2D Apex and 3D Apex from LV base was calculated and expressed as percentage (2D Apex/3D Apex). Results 2D Apex/3D Apex was strongly related to the magnitude of twist and untwisting rate (r=0 center dot 82, P<0 center dot 001; r=0 center dot 46, P=0 center dot 015, respectively). The only determinant of twist was 2D Apex/3D Apex (r2=0 center dot 68; r=0 center dot 82; F ratio: 52 center dot 6, P<0 center dot 001); whereas untwisting rate was influenced by 2D Apex/3D Apex and age (r2=0 center dot 42; r=0 center dot 65; F ratio: 7 center dot 7; P=0 center dot 003 for 2D Apex/3D Apex; and P=0 center dot 011 for age). Conclusions Left ventricular apical level acquisition, even when recorded in a standard manner, determines variability of twist mechanics measurements. Thus, current anatomical markers used to identify LV apex for twist analysis are not reliable and need different standardization. 3D echocardiography may help in such standardization.
引用
收藏
页码:117 / 121
页数:5
相关论文
共 50 条
  • [1] Left ventricular torsion based on 2D speckle tracking echocardiography (STE) is preload insensitive
    Gao, Zhaohui
    Drew, Rachel C.
    Momen, Afsana
    Ndukwu, Ifesinachi
    Muller, Matthew D.
    Mast, Jessica
    Blaha, Cheryl
    Leuenberger, Urs A.
    Sinoway, Lawrence I.
    FASEB JOURNAL, 2012, 26
  • [2] Evaluation of Left Ventricular Function in Healthy Retrievers Using Standard and 2D Speckle-Tracking Echocardiography
    Hamabe, Lina
    Shimada, Kazumi
    Mandour, Ahmed S.
    Yoshida, Tomohiko
    Hirose, Miki
    Hendawy, Hanan
    El-Husseiny, Hussein M.
    Tanaka, Ryou
    VETERINARY SCIENCES, 2022, 9 (10)
  • [3] Right Ventricular Pacing-Induced Effects on Left Ventricular Function According to 2D Speckle-Tracking Echocardiography
    Khalil, Noran Ibraim
    Ashmawy, Medhat Mohamed
    El-Said, Ayman Mohamed
    El-Din, Samia Mahmoud Sharaf
    El-Barbary, Yasser Hussein
    IRANIAN HEART JOURNAL, 2023, 24 (01): : 78 - 85
  • [4] Right ventricular 2D speckle-tracking echocardiography in children with osteosarcoma under chemotherapy
    Khairat, Ibtsam
    Khalfallah, Mohamed
    Shaban, Aliaa
    Abu Farag, Ibrahim
    Elkady, Asmaa
    EGYPTIAN HEART JOURNAL, 2019, 71 (01):
  • [5] Right ventricular 2D speckle-tracking echocardiography in children with osteosarcoma under chemotherapy
    Ibtsam Khairat
    Mohamed Khalfallah
    Aliaa Shaban
    Ibrahim Abu Farag
    Asmaa Elkady
    The Egyptian Heart Journal, 71
  • [6] Sources of variation in assessing left atrial functions by 2D speckle-tracking echocardiography
    Rimbas, Roxana Cristina
    Mihaila, Sorina
    Vinereanu, Dragos
    HEART AND VESSELS, 2016, 31 (03) : 370 - 381
  • [7] Sources of variation in assessing left atrial functions by 2D speckle-tracking echocardiography
    Roxana Cristina Rimbaş
    Sorina Mihăilă
    Dragoş Vinereanu
    Heart and Vessels, 2016, 31 : 370 - 381
  • [8] Effects of vitamin D deficiency on left atrial function as evaluated by 2D speckle-tracking echocardiography
    Akhavan-Khaleghi, Niloofar
    Hosseinsabet, Ali
    Mohseni-Badalabadi, Reza
    JOURNAL OF CLINICAL ULTRASOUND, 2018, 46 (05) : 334 - 340
  • [9] Right Ventricular Assessment by 2D Speckle-Tracking Echocardiography Before CABG in Patients With Preserved or Mild Left Ventricular Systolic Function
    Sahebjam, Mohammad
    Norouzi, Somayyeh
    Ghavami, Mojgan
    Montazeri, Seyed Mohammad Hashem
    Mehrabanian, Mohammad Javad
    Jalali, Arash
    Zoroofian, Arezoo
    Aghaali, Mohammad
    IRANIAN HEART JOURNAL, 2024, 25 (01): : 82 - 92
  • [10] Left atrial function evaluation by 2D speckle-tracking echocardiography in patients with vasovagal syncope
    Tajdini, Masih
    Hosseinsabet, Ali
    Tofighi, Saeed
    Yadangi, Somayeh
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2023, 46 (04): : 300 - 308